UZ super-compact • R32 SINGLE PHASE
2.50 kW 3.30 kW 5.00 kW
Kit KIT-UZ25-ZKE KIT-UZ35-ZKE KIT-UZ50-ZKE
Cooling capacity (Nominal) kW 2,50 3,30 5,00
Cooling capacity (Min) kW 0,85 0,85 0,98
Cooling capacity (Max) kW 3,00 3,90 5,40
EER (Nominal) (1) W/W 3,68 3,24 3,03
EER (Min) (1) W/W 4,05 3,54 3,92
EER (Max) (1) W/W 3,33 3,00 2,89
SEER (2) 6,20 A++ 6,20 A++ 6,50 A++
Pdesign (cooling) kW 2,5 3,3 5
Input power cooling (Nominal) kW 0,68 1,02 1,65
Input power cooling (Min) kW 0,21 0,24 0,25
Input power cooling (Max) kW 0,90 1,30 1,87
Annual energy consumption cooling (3) kWh/a 141 186 269
Heating capacity (Nominal) kW 3,15 3,70 5,40
Heating capacity (Min) kW 0,80 0,80 0,98
Heating capacity (Max) kW 3,60 4,40 7,40
Heating capacity at -7°C kW 2,14 2,60 4,52
COP (Nominal) (1) W/W 4,06 3,72 3,42
COP (Min) (1) W/W 4,21 4,10 4,67
COP (Max) (1) W/W 3,50 3,46 3,08
SCOP (2) 4,20 A+ 4,10 A+ 4,10 A+
Pdesign at -10°C kW 1,9 2,4 4
Input power heating (Nominal) kW 0,78 1,00 1,58
Input power heating (Min) kW 0,19 0,20 0,21
Input power heating (Max) kW 1,03 1,27 2,40
Annual energy consumption heating (3) kWh/a 633 820 1.366
Indoor unit CS-UZ25ZKE CS-UZ35ZKE CS-UZ50ZKE
Indoor power source V 230 230 230
Indoor recommended fuse A 16 16 16
Indoor connection indoor / outdoor mm² 4 x 1,5 4 x 1,5 4 x 2,5
Indoor air flow (Cool) m³/min 10,5 10,8 12,5
Indoor air flow (Heat) m³/min 9,5 11,3 13,2
Moisture removal volume L/h 1,5 1,9 2,8
Indoor sound pressure (Cool - Hi) (4) dB(A) 37 38 44
Indoor sound pressure (Cool - Hi) (4) dB(A) 37 38 44
Indoor sound pressure (Cool - Lo) (4) dB(A) 26 30 37
Indoor sound pressure (Cool - Q-Lo) (4) dB(A) 20 20 34
Indoor sound pressure (Heat - Hi) (4) dB(A) 36 38 44
Indoor sound pressure (Heat - Lo) (4) dB(A) 27 33 37
Indoor sound pressure (Heat - Q-Lo) (4) dB(A) 24 25 34
Indoor dimension (Height) mm 290 290 290
Indoor dimension (Width) mm 779 779 779
Indoor dimension (Depth) mm 209 209 209
Indoor net weight kg 8 8 8
Outdoor unit CU-UZ25ZKE CU-UZ35ZKE CU-UZ50ZKE
Outdoor air flow (Cool) m³/min 30,4 31,1 32,7
Outdoor air flow (Heat) m³/min 30,4 30,4 32,7
Outdoor sound pressure (Cool - Hi) (4) dB(A) 48 48 48
Outdoor sound pressure (Cool - Hi) (4) dB(A) 48 48 48
Outdoor sound pressure (Heat - Hi) (4) dB(A) 49 50 49
Outdoor dimension (Height) (5) mm 542 542 619
Outdoor dimension (Width) (5) mm 780 780 824
Outdoor dimension (Depth) (5) mm 289 289 299
Outdoor net weight kg 24 25 35
Piping diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Piping diameter (Gas) Inch (mm) 3/8 (9,52) 3/8 (9,52) 1/2 (12,70)
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 15
Elevation difference (in/out) (6) m 15 15 15
Pre-charged pipe length m 7,5 7,5 10
Additional gas amount g/m 10 10 15
Refrigerant (R32) / CO2 Eq. kg / T 0,52 / 0,35 0,61 / 0,41 1,07 / 0,72
Operating range (Cool - Min) °C -10 -10 -10
Operating range (Cool - Min) °C -10 -10 -10
Operating range (Cool - Max) °C +43 +43 +43
Operating range (Heat - Min) °C -15 -15 -15
Operating range (Heat - Max) °C +24 +24 +24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.

Complementary products