Models
Aquarea T-CAP Bi-Bloc K Series
A revolution in design, efficiency, connectivity and sustainability.Aquarea K Series is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance.
- A+++ in heating at 35°C
- “A” water pump with variable speed
- Built-in flow meter
- Built-in magnetic water filter
- Constant capacity down to -20°C
- Operating range down to -28°C
- 60°C hot water even at -10°C outside temperature
- Optimised user interface and improved features
- Optional Aquarea Smart and Service Cloud and integration into BMS projects
Owning an Aquarea?
Specifications
T-CAP Bi-bloc K Series 1 phase - 3 phase · R32 | SINGLE PHASE | THREE PHASE | |||||
---|---|---|---|---|---|---|---|
9 kW | 12 kW | 9 kW | 12 kW | 16 kW | |||
Kit 3kW electric heater | KIT-WXC09K3E5 | KIT-WXC09K3E8 | — | ||||
Kit 6kW electric heater | KIT-WXC09K6E5 | KIT-WXC12K6E5 | — | ||||
Kit 9kW electric heater | — | — | KIT-WXC09K9E8 | KIT-WXC12K9E8 | KIT-WXC16K9E8 | ||
Heating capacity (A +7°C, W 35°C) | kW | 9,00 | 12,10 | 9,00 | 12,10 | 16,00 | |
COP (A +7°C, W 35°C) | 5,03 | 4,84 | 5,03 | 4,84 | 4,38 | ||
Heating capacity (A +7°C, W 55°C) | kW | 9,00 | 12,10 | 9,00 | 12,10 | 16,00 | |
COP (A +7°C, W 55°C) | 3,07 | 3,04 | 3,07 | 3,04 | 2,72 | ||
Heating capacity (A +2°C, W 35°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
COP (A +2°C, W 35°C) | 3,69 | 3,44 | 3,69 | 3,44 | 3,10 | ||
Heating capacity (A +2°C, W 55°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
COP (A +2°C, W 55°C) | 2,31 | 2,29 | 2,31 | 2,29 | 2,07 | ||
Heating capacity (A -7°C, W 35°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
COP (A -7°C, W 35°C) | 3,00 | 2,72 | 3,00 | 2,72 | 2,39 | ||
Heating capacity (A -7°C, W 55°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
COP (A -7°C, W 55°C) | 2,10 | 2,29 | 2,10 | 2,29 | 1,71 | ||
Cooling capacity (A 35°C, W 7°C) | kW | 8,80 | 10,70 | 8,80 | 10,70 | 13,40 | |
EER (A 35°C, W 7°C) | 3,11 | 2,68 | 3,11 | 2,68 | 2,64 | ||
Cooling capacity (A 35°C, W 18°C) | kW | 8,80 | 10,70 | 8,80 | 10,70 | 13,40 | |
EER (A 35°C, W 18°C) | 4,63 | 3,92 | 4,63 | 3,92 | 2,64 | ||
Heating average climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) | SCOP | 4,96 / 3,57 | 4,96 / 3,57 | 4,96 / 3,57 | 4,58 / 3,46 | 4,46 / 3,31 | |
Heating average climate. Seasonal energy efficiency η (W 35°C / W 55°C) | ηs % | 195 / 140 | 195 / 140 | 195 / 140 | 180 / 135 | 176 / 129 | |
Heating average climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | A+++ / A++ | A+++ / A++ | A+++ / A++ | A+++ / A++ | |
Heating cold climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) | SCOP | 6,47 / 4,34 | 6,47 / 4,34 | 6,47 / 4,34 | 6,47 / 4,34 | 5,88 / 4,09 | |
Heating cold climate. Seasonal energy efficiency η (W 35°C / W 55°C) | ηs % | 256 / 171 | 256 / 171 | 256 / 171 | 256 / 171 | 232 / 160 | |
Heating cold climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | A+++ / A+++ | A+++ / A+++ | A+++ / A+++ | A+++ / A+++ | |
Heating warm climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) | SCOP | 4,31 / 3,26 | 4,31 / 3,26 | 4,31 / 3,26 | 4,31 / 3,26 | 3,83 / 3,20 | |
Heating warm climate. Seasonal energy efficiency η (W 35°C / W 55°C) | ηs % | 169 / 127 | 169 / 127 | 169 / 127 | 169 / 127 | 150 / 125 | |
Heating warm climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A++ / A++ | A++ / A++ | A++ / A++ | A++ / A++ | A++ / A++ | |
Indoor unit 3kW electric heater | WH-SXC09K3E5 | — | WH-SXC09K3E8 | — | — | ||
Indoor unit 6kW electric heater | WH-SXC09K6E5 | WH-SXC12K6E5 | — | — | — | ||
Indoor unit 9kW electric heater | — | — | WH-SXC09K9E8 | WH-SXC12K9E8 | WH-SXC16K9E8 | ||
Indoor sound pressure (Heat) | dB(A) | 33 | 33 | 33 | 33 | 33 | |
Indoor sound pressure (Cool) | dB(A) | 33 | 33 | 33 | 33 | 33 | |
Indoor dimension (Height) | mm | 892 | 892 | 892 | 892 | 892 | |
Indoor dimension (Width) | mm | 500 | 500 | 500 | 500 | 500 | |
Indoor dimension (Depth) | mm | 348 | 348 | 348 | 348 | 348 | |
Indoor net weight | kg | 40 (3kW) / 41 (6kW) | 41 | 40 (3kW) / 41 (9kW) | 41 | 42 | |
Water pipe connector | Inch | R 1¼ | R 1¼ | R 1¼ | R 1¼ | R 1¼ | |
A class pump (Number of speeds) | Variable speed | Variable speed | Variable speed | Variable speed | Variable speed | ||
A class pump (Input power) | W | 145 | 145 | 145 | 145 | 173 | |
Heating water flow (∆T=5 K. 35°C) | L/min | 25,8 | 34,4 | 25,8 | 34,4 | 45,9 | |
Outdoor unit | WH-UXZ09KE5 | WH-UXZ12KE5 | WH-UXZ09KE8 | WH-UXZ12KE8 | WH-UXZ16KE8 | ||
Outdoor sound power (Heat) (2) | dB(A) | 65 | 65 | 65 | 65 | 65 | |
Outdoor dimension (Height) | mm | 1.340 | 1.340 | 1.340 | 1.340 | 1.340 | |
Outdoor dimension (Width) | mm | 900 | 900 | 900 | 900 | 900 | |
Outdoor dimension (Depth) | mm | 320 | 320 | 320 | 320 | 320 | |
Outdoor net weight | kg | 88 | 88 | 90 | 90 | 103 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,60 / 1,080 | 1,60 / 1,080 | 1,60 / 1,080 | 1,60 / 1,080 | 1,83 / 1,235 | |
Piping diameter (Liquid) | Inch (mm) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | |
Piping diameter (Gas) | Inch (mm) | 1/2 (12,70) | 1/2 (12,70) | 1/2 (12,70) | 1/2 (12,70) | 1/2 (12,70) | |
Pipe length range | m | 3 ~ 30 | 3 ~ 30 | 3 ~ 30 | 3 ~ 30 | 3 ~ 30 | |
Elevation difference (in/out) | m | 20 | 20 | 20 | 20 | 20 | |
Pre-charged pipe length | m | 10 | 10 | 10 | 10 | 10 | |
Additional gas amount | g/m | 30 | 30 | 30 | 30 | 30 | |
Operation range - Outdoor ambient (Heat) | °C | -28 ~ +35 | -28 ~ +35 | -28 ~ +35 | -28 ~ +35 | -28 ~ +35 | |
Operation range - Outdoor ambient (Cool) | °C | +10 ~ +43 | +10 ~ +43 | +10 ~ +43 | +10 ~ +43 | +10 ~ +43 | |
Water outlet (Heat) (3) | °C | 20 ~ 60 | 20 ~ 60 | 20 ~ 60 | 20 ~ 60 | 20 ~ 60 | |
Water outlet (Cool) (4) | °C | 5 ~ 20 | 5 ~ 20 | 5 ~ 20 | 5 ~ 20 | 5 ~ 20 | |
Electrical information | 3kW — 6kW | 6kW | 3kW — 9kW | 9kW | 9kW | ||
Electric backup heater | kW | 3,00 — 6,00 | 6,00 | 3,00 — 9,00 | 9,00 | 9,00 | |
Recommended fuse | A | 30 / 15 or 16 — 30 / 30 | 30 / 30 | 20 / 15 or 16 — 20 / 20 | 20 / 20 | 20 / 20 | |
Recommended minimum cable size, supply 1 (4) | mm² | 3x4,0 — 3x4,0 | 3x4,0 | 5x1,5 — 5x1,5 | 5x1,5 | 5x2,5 | |
Recommended minimum cable size, supply 2 (4) | mm² | 3x1,5 — 3x4,0 | 3x4,0 | 3x1,5 — 5x1,5 | 5x1,5 | 5x1,5 |
(2) Sound power level in accordance to EN12102 under conditions of the EN14825.
(3) Between outdoor ambient -10°C and -15°C, the water outlet temperature gradually decreases from 60°C to 55°C.
(4) Check local regulations.
* Available in Summer 2024.
** EER and COP calculation is based in accordance to EN14511.
*** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.