T-CAP All in One K Series 1 phase - 3 phase · R32

Aquarea T-CAP All in One K Series

A revolution in design, efficiency, connectivity and sustainability.
Aquarea K Series is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance.
Aquarea T-CAP is the range for retrofit and new builds, keeping Total Capacity even at extremely cold ambient.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit. The All in One model maintains its compactness with its encroachment of only 598 x 600mm, comparable to a household appliance.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.

Owning an Aquarea?

Specifications

See all
T-CAP All in One K Series 1 phase - 3 phase · R32 SINGLE PHASE THREE PHASE
9 kW 12 kW 9 kW 12 kW 16 kW
Kit KIT-AXC09K6E5 KIT-AXC12K6E5 KIT-AXC09K9E8* KIT-AXC12K9E8* KIT-AXC16K9E8*
Heating capacity (A +7°C, W 35°C) kW 9,00 12,10 9,00 12,10 16,00
COP (A +7°C, W 35°C) 5,03 4,84 5,03 4,84 4,38
Heating capacity (A +7°C, W 55°C) kW 9,00 12,10 9,00 12,10 16,00
COP (A +7°C, W 55°C) 3,07 3,04 3,07 3,04 2,72
Heating capacity (A +2°C, W 35°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A +2°C, W 35°C) 3,69 3,44 3,69 3,44 3,10
Heating capacity (A +2°C, W 55°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A +2°C, W 55°C) 2,31 2,29 2,31 2,29 2,07
Heating capacity (A -7°C, W 35°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A -7°C, W 35°C) 3,00 2,72 3,00 2,72 2,39
Heating capacity (A -7°C, W 55°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A -7°C, W 55°C) 2,10 2,29 2,10 2,29 1,71
Cooling capacity (A 35°C, W 7°C) kW 8,80 10,70 8,80 10,70 13,40
EER (A 35°C, W 7°C) 3,11 2,68 3,11 2,68 2,64
Cooling capacity (A 35°C, W 18°C) kW 8,80 10,70 8,80 10,70 13,40
EER (A 35°C, W 18°C) 4,63 3,92 4,63 3,92 2,64
Heating average climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,96 / 3,57 4,96 / 3,57 4,96 / 3,57 4,58 / 3,46 4,46 / 3,31
Heating average climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 195 / 140 195 / 140 195 / 140 180 / 135 176 / 129
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 6,47 / 4,34 6,47 / 4,34 6,47 / 4,34 6,47 / 4,34 5,88 / 4,09
Heating warm climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 256 / 171 256 / 171 256 / 171 256 / 171 232 / 160
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,31 / 3,26 4,31 / 3,26 4,31 / 3,26 4,31 / 3,26 3,83 / 3,20
Heating cold climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 169 / 127 169 / 127 169 / 127 169 / 127 150 / 125
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++
Indoor unit WH-ADC0912K6E5 WH-ADC0912K6E5 WH-ADC0912K9E8 WH-ADC0912K9E8 WH-ADC16K9E8
Indoor sound pressure (Heat) dB(A) 33 33 33 33 33
Indoor sound pressure (Cool) dB(A) 33 33 33 33 33
Indoor dimension (Height) mm 1.642 1.642 1.642 1.642 1.642
Indoor dimension (Width) mm 599 599 599 599 599
Indoor dimension (Depth) mm 602 602 602 602 602
Indoor net weight kg 101 101 102 102 103
Water pipe connector Inch R 1¼ R 1¼ R 1¼ R 1¼ R 1¼
A class pump (Number of speeds) Variable speed Variable speed Variable speed Variable speed Variable speed
A class pump (Input power) W 145 145 145 145 173
Heating water flow (∆T=5 K. 35°C) L/min 25,8 34,4 25,8 34,4 45,9
Water volume L 185 185 185 185 185
Maximum DHW temperature °C 65 65 65 65 65
Material inside tank Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
Tapping profile according EN16147 L L L L L
DHW tank ERP average climate efficiency rating (2) A+ to F A A A A A
DHW tank ERP warm climate efficiency rating (2) A+ to F A+ A+ A+ A+ A+
DHW tank ERP cold climate efficiency rating (2) A+ to F A A A A A
DHW tank ERP average climate η ηwh % 112 112 112 112 107
DHW tank ERP average climate COPdHW COPdHW 2,80 2,80 2,80 2,80 2,68
DHW tank ERP warm climate η ηwh % 132 132 132 132 128
DHW tank ERP warm climate COPdHW COPdHW 3,30 3,30 3,30 3,30 3,20
DHW tank ERP cold climate η ηwh % 88 88 88 88 84
DHW tank ERP cold climate COPdHW COPdHW 2,20 2,20 2,20 2,20 2,10
Outdoor unit WH-UXZ09KE5 WH-UXZ12KE5 WH-UXZ09KE8 WH-UXZ12KE8 WH-UXZ16KE8
Outdoor sound power (Heat) (3) dB(A) 65 65 65 65 65
Outdoor dimension (Height) mm 1.340 1.340 1.340 1.340 1.340
Outdoor dimension (Width) mm 900 900 900 900 900
Outdoor dimension (Depth) mm 320 320 320 320 320
Outdoor net weight kg 88 88 90 90 103
Refrigerant (R32) / CO2 Eq. kg / T 1,60 / 1,080 1,60 / 1,080 1,60 / 1,080 1,60 / 1,080 1,83 / 1,235
Piping diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Piping diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70)
Pipe length range m 3 ~ 30 3 ~ 30 3 ~ 30 3 ~ 30 3 ~ 30
Elevation difference (in/out) m 20 20 20 20 20
Pre-charged pipe length m 10 10 10 10 10
Additional gas amount g/m 30 30 30 30 30
Operation range - Outdoor ambient (Heat) °C -28 ~ +35 -28 ~ +35 -28 ~ +35 -28 ~ +35 -28 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43
Water outlet (Heat) (4) °C 20 ~ 60 20 ~ 60 20 ~ 60 20 ~ 60 20 ~ 60
Water outlet (Cool) (4) °C 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20
Electrical information WH-ADC0912K6E5 WH-ADC0912K6E5 WH-ADC0912K9E8 WH-ADC0912K9E8 WH-ADC16K9E8
Electric backup heater kW 6,00 6,00 9,00 9,00 9,00
Recommended fuse A 30 / 30 30 / 30 20 / 20 20 / 20 20 / 20
Recommended minimum cable size, supply 2 (5) mm² 3x4,0 3x4,0 5x1,5 5x1,5 5x2,5
Recommended minimum cable size, supply 1 (5) mm² 3x4,0 3x4,0 5x1,5 5x1,5 5x1,5
(1) Scale from A+++ to D.
(2) Scale from A+ to F.
(3) Sound power level in accordance to EN12102 under conditions of the EN14825.
(4) Between outdoor ambient -10°C and -15°C, the water outlet temperature gradually decreases from 60°C to 55°C.
(5) Check local regulations.
* Available in Summer 2024.
** EER and COP calculation is based in accordance to EN14511.
*** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility
.

Complementary products