PACi NX Series Standard ceiling Inverter+ - R32

Ceiling mounted units provide large and wide air distribution which is good for big rooms

The height and depth of all capacities are the same for unified appearance in mixed installations.

The next generation of commercial air conditioners is here

Specifications

See all
PACi NX Series Standard ceiling Inverter+ - R32 SINGLE PHASE THREE PHASE
3.6 kW 5.0 kW 6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 10.0 kW 12.5 kW 14.0 kW
Kit KIT-36PT3Z5 KIT-50PT3Z5 KIT-60PT3Z5 KIT-71PT3Z5 KIT-100PT3Z5 KIT-125PT3Z5 KIT-140PT3Z5 KIT-100PT3Z8 KIT-125PT3Z8 KIT-140PT3Z8
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 3,5 5,0 6,0 6,8 10,0 12,5 14,0 10,0 12,5 14,0
Cooling capacity (Min) kW 1,5 1,5 2,0 2,6 3,0 3,2 3,3 3,0 3,2 3,3
Cooling capacity (Max) kW 4,0 5,2 7,1 7,7 11,5 13,5 15,0 11,5 13,5 15,0
EER (Nominal) (1) W/W 4,14 3,03 3,59 3,24 3,64 3,32 2,98 3,64 3,32 2,98
SEER/ηs,c (2) % 7,2 A++ 6,7 A++ 7,3 A++ 5,9 A+ 6,6 A++ 241,7 % 228,8 % 6,5 A++ 240,9 % 228,1 %
Pdesign (cooling) kW 3,5 5,0 6,0 6,8 10,0 12,5 14,0 10,0 12,5 14,0
Input power cooling (Nominal) kW 0,85 1,65 1,67 2,10 2,75 3,76 4,70 2,75 3,76 4,70
Annual energy consumption cooling (3) kWh/a 171 262 288 404 531 537
Heating capacity (Nominal) kW 3,5 5,0 6,0 6,8 10,0 12,5 14,0 10,0 12,5 14,0
Heating capacity (Min) kW 1,5 1,5 1,8 2,1 3,0 3,3 3,4 3,0 3,3 3,4
Heating capacity (Max) kW 4,6 6,4 7,0 8,1 14,0 15,0 16,0 14,0 15,0 16,0
COP (Nominal) (1) W/W 4,61 3,73 4,11 4,20 4,24 3,89 3,70 4,24 3,89 3,70
SCOP/ηs,h (2) % 4,4 A+ 4,1 A+ 4,6 A++ 4,3 A+ 4,2 A+ 147,4 % 145,3 % 4,2 A+ 147,4 % 145,3 %
Pdesign at -10°C kW 2,8 4,0 4,6 4,7 10,0 12,5 13,6 10,0 12,5 13,6
Input power heating (Nominal) kW 0,76 1,34 1,46 1,62 2,36 3,21 3,78 2,36 3,21 3,78
Annual energy consumption heating (3) kWh/a 891 1.365 1.399 1.529 3.331 3.331
Indoor unit S-3650PT3E S-3650PT3E S-6071PT3E S-6071PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E
Indoor air flow (Hi) m³/min 14,0 15,0 20,0 21,0 30,0 34,0 35,0 30,0 34,0 35,0
Indoor air flow (Med) m³/min 12,0 12,5 17,0 18,0 25,0 28,0 29,0 25,0 28,0 29,0
Indoor air flow (Lo) m³/min 10,5 10,5 14,5 15,5 23,0 24,0 25,0 23,0 24,0 25,0
Moisture removal volume L/h 0,8 2,0 2,1 2,7 4,1 5,7 6,9 4,1 5,7 6,9
Indoor sound pressure (Med) (4) dB(A) 32 33 34 35 37 40 41 37 40 41
Indoor sound pressure (Lo) (4) dB(A) 28 28 29 30 34 35 36 34 35 36
Indoor sound power (Hi) dB(A) 54 55 56 57 60 64 65 60 64 65
Indoor sound power (Med) dB(A) 50 51 52 53 55 58 59 55 58 59
Indoor sound power (Lo) dB(A) 46 46 47 48 52 53 54 52 53 54
Indoor dimension (Height) mm 235 235 235 235 235 235 235 235 235 235
Indoor dimension (Width) mm 960 960 1.275 1.275 1.590 1.590 1.590 1.590 1.590 1.590
Indoor dimension (Depth) mm 690 690 690 690 690 690 690 690 690 690
Indoor net weight kg 26 26 34 34 40 40 40 40 40 40
nanoe X Generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Outdoor unit U-36PZ3E5 U-50PZ3E5 U-60PZ3E5A U-71PZ3E5A U-100PZ3E5 U-125PZ3E5 U-140PZ3E5 U-100PZ3E8 U-125PZ3E8 U-140PZ3E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 3,90 7,65 7,75 9,75 13,70 18,20 22,70 4,60 6,10 7,60
Current in cooling (1p 230V / 3p 400) A 3,75 7,30 7,40 9,30 13,10 17,40 21,70 4,35 5,75 7,20
Current in cooling (1p 240V / 3p 415) A 3,60 7,00 7,10 8,95 12,60 16,70 20,80 4,20 5,55 6,95
Current in heating (1p 220V / 3p 380) A 3,55 6,30 6,75 7,50 11,80 15,50 18,30 3,95 5,20 6,10
Current in heating (1p 230V / 3p 400) A 3,40 6,00 6,50 7,20 11,30 14,80 17,50 3,75 4,95 5,80
Current in heating (1p 240V / 3p 415) A 3,25  5,75 6,20 6,90 10,80 14,20 16,80 3,60 4,75 5,60
Outdoor air flow (Cool) m³/min 33,6 32,7 42,6 44,7 73,0 82,0 84,0 73,0 82,0 84,0
Outdoor air flow (Heat) m³/min 34,0 31,9 41,5 45,9 73,0 80,0 82,0 73,0 80,0 82,0
Outdoor sound pressure (Cool - Hi) dB(A) 46 46 47 48 52 55 56 52 55 56
Outdoor sound pressure (Heat - Hi) dB(A) 47 46 48 49 52 55 56 52 55 56
Outdoor sound power (Cool -Hi) dB(A) 64 64 64 66 70 73 74 70 73 74
Outdoor sound power (Heat -Hi) dB(A) 66 64 65 68 70 73 74 70 73 74
Outdoor dimension (Height) mm 619 619 695 695 996 996 996 996 996 996
Outdoor dimension (Width) mm 824 824 875 875 980 980 980 980 980 980
Outdoor dimension (Depth) mm 299 299 320 320 370 370 370 370 370 370
Outdoor net weight kg 32 35 42 50 83 87 87 83 87 87
Piping diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) (5) 1/4 (6,35) (5) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Piping diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70) (6) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 15 3 ~ 20 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50
Elevation difference (in/out) (7) m 15 / 15 (8) 15 / 15 (8) 15 / 30 (8) 20 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8)
Pre-charged pipe length m 7,5 7,5 30 30 30 30 30 30 30 30
Additional gas amount g/m 10 15 15 17 45 45 45 45 45 45
Refrigerant (R32) / CO2 Eq. kg / T 0,87 / 0,59 1,14 / 0,77 1,15 / 0,78 1,32 / 0,89 2,40 / 1,62 2,80 / 1,89 2,80 / 1,89 2,40 / 1,62 2,80 / 1,89 2,80 / 1,89
Operating range (Cool - Min) °C -10 -10 -10 -10 -10 -10 -10 -10 -10 -10
Operating range (Cool - Max) °C +43 +43 +43 +43 +43 +43 +43 +43 +43 +43
Operating range (Heat - Min) °C -15 -15 -15 -15 -15 -15 -15 -15 -15 -15
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24 +24 +24 +24

1) EER and COP calculation is based in accordance to EN14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηsc / ηsh values is calculated based on EN 14825.
3) Factory setting.
4) The sound pressure of the units shows the value measured of the position 1m in front of the main body and 1m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit.
7) When installing the outdoor unit at a higher position than the indoor unit.
8) Outdoor unit located lower / outdoor unit located higher.
* Recommended fuse for the indoor 3A.
** Above values are in the case of nanoe™ X OFF.