PACi NX Series Elite 4 way 90x90 cassette Inverter+ - R32

4 way 90x90 cassette - PU3

Powerful turbo fan and intelligent Econavi sensor ensure high energy efficiency, and nanoe™ X which is equipped as standard provides an exceptional level of indoor air quality.

The next generation of commercial air conditioners is here

Specifications

See all
PACi NX Series Elite 4 way 90x90 cassette Inverter+ - R32 SINGLE PHASE THREE PHASE
3.6 kW 5.0 kW 6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW
Kit KIT-36PU3ZH5 KIT-50PU3ZH5 KIT-60PU3ZH5 KIT-71PU3ZH45 KIT-100PU3ZH45 KIT-125PU3ZH45 KIT-140PU3ZH45 KIT-71PU3ZH48 KIT-100PU3ZH48 KIT-125PU3ZH48 KIT-140PU3ZH48
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 3,6 5,0 6,0 7,1 9,5 12,5 13,4 7,1 9,5 12,5 13,4
Cooling capacity (Min) kW 1,2 1,2 1,2 2,2 3,1 3,2 3,3 2,2 3,1 3,2 3,3
Cooling capacity (Max) kW 4,0 5,6 7,1 9,0 12,5 14,0 16,0 9,0 12,5 14,0 16,0
EER (Nominal) (1) W/W 5,45 4,31 4,05 4,06 4,42 3,80 3,60 4,06 4,42 3,80 3,60
EER (Min) (1) W/W 2,69 3,42 3,08 2,74 2,69 3,42 3,08 2,74
EER (Max) (1) W/W 5,79 5,34 5,33 5,32 5,79 5,34 5,33 5,32
SEER/ηs,c (2) % 8,9 A+++ 8,6 A+++ 8,0 A++ 7,7 A++ 7,8 A++ 304,3% 286,6% 7,7 A++ 7,2 A++ 303,0% 286,6%
Pdesign (cooling) kW 3,6 5,0 6,0 7,1 9,5 12,5 13,4 7,1 9,5 12,5 13,4
Input power cooling (Nominal) kW 0,66 1,16 1,48 1,75 2,15 3,29 3,72 1,75 2,15 3,29 3,72
Input power cooling (Min) kW 0,38 0,58 0,60 0,62 0,38 0,58 0,60 0,62
Input power cooling (Max) kW 3,35 3,65 4,55 5,85 3,35 3,65 4,55 5,85
Annual energy consumption cooling (3) kWh/a 142 203 263 323 426 323 426
Heating capacity (Nominal) kW 4,0 5,6 7,0 8,0 11,2 14,0 16,0 8,0 11,2 14,0 16,0
Heating capacity (Min) kW 1,2 1,2 1,2 2,0 3,1 3,2 3,3 2,0 3,1 3,2 3,3
Heating capacity (Max) kW 5,0 6,5 8,0 9,0 14,0 16,0 18,0 9,0 14,0 16,0 18,0
COP (Nominal) (1) W/W 5,41 4,24 4,02 4,30 5,00 4,61 4,30 4,30 5,00 4,61 4,30
COP (Min) (1) W/W 3,16 3,64 3,37 3,27 3,16 3,64 3,37 3,27
COP (Max) (1) W/W 5,56 5,54 5,52 5,50 5,56 5,54 5,52 5,50
SCOP/ηs,h (2) % 5,1 A+++ 4,9 A++ 4,8 A++ 4,8 A++ 4,9 A++ 186,0% 181,2% 4,8 A++ 4,9 A++ 186,0% 181,1%
Pdesign at -10°C kW 3,6 4,5 4,7 5,2 8,0 9,5 10,6 5,2 8,0 9,5 10,6
Input power heating (Nominal) kW 0,74 1,32 1,74 1,86 2,24 3,04 3,72 1,86 2,24 3,04 3,72
Input power heating (Min) kW 0,36 0,56 0,58 0,60 0,36 0,56 0,58 0,60
Input power heating (Max) kW 2,85 3,85 4,75 5,50 2,85 3,85 4,75 5,50
Annual energy consumption heating (3) kWh/a 988 1.286 1.371 1.517 2.286 1.517 2.286
Indoor unit S-3650PU3E S-3650PU3E S-6071PU3E S-6071PU3E S-1014PU3E S-1014PU3E S-1014PU3E S-6071PU3E S-1014PU3E S-1014PU3E S-1014PU3E
Indoor air flow (Hi) m³/min 14,5 16,5 21,0 22,0 36,0 37,0 38,0 22,0 36,0 37,0 38,0
Indoor air flow (Med) m³/min 13,0 13,5 16,0 16,0 26,0 27,0 29,0 16,0 26,0 27,0 29,0
Indoor air flow (Lo) m³/min 11,5 11,5 13,0 13,0 18,0 19,0 20,0 13,0 18,0 19,0 20,0
Moisture removal volume L/h 0,7 1,6 1,7 2,5 1,9 4,8 4,9 2,5 1,9 4,8 4,9
Indoor sound pressure (Med) (4) dB(A) 28 29 31 31 38 39 40 31 38 39 40
Indoor sound pressure (Lo) (4) dB(A) 27 27 28 28 32 33 34 28 32 33 34
Indoor sound power (Hi) dB(A) 45 47 51 52 60 61 62 52 60 61 62
Indoor sound power (Med) dB(A) 43 44 46 46 53 54 55 46 53 54 55
Indoor sound power (Lo) dB(A) 42 42 43 43 47 48 49 43 47 48 49
Indoor dimension (Height) mm 256 256 256 256 319 319 319 256 319 319 319
Indoor dimension (Width) mm 840 840 840 840 840 840 840 840 840 840 840
Indoor dimension (Depth) mm 840 840 840 840 840 840 840 840 840 840 840
Panel dimension (Height) mm 33,5 33,5 33,5 33,5 33,5 33,5 33,5 33,5 33,5 33,5 33,5
Panel dimension (Depth) mm 950 950 950 950 950 950 950 950 950 950 950
Indoor net weight kg 19 19 20 20 25 25 25 20 25 25 25
Panel net weight kg 5 5 5 5 5 5 5 5 5 5 5
nanoe X Generator Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1
Outdoor unit U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 U-71PZH4E5 U-100PZH4E5 U-125PZH4E5 U-140PZH4E5 U-71PZH4E8 U-100PZH4E8 U-125PZH4E8 U-140PZH4E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 3,25 5,50 6,95 8,85 10,06 16,10 18,20 2,95 3,60 5,45 6,15
Current in cooling (1p 230V / 3p 400) A 3,10 5,25 6,65 8,45 10,02 15,40 17,40 2,80 3,40 5,15 5,85
Current in cooling (1p 240V / 3p 415) A 3,00 5,05 6,35 8,10 9,75 14,70 16,70 2,70 3,25 5,00 5,65
Current in heating (1p 220V / 3p 380) A 3,60 6,25 8,05 9,40 10,90 14,90 18,20 3,15 3,75 5,10 6,20
Current in heating (1p 230V / 3p 400) A 3,45 6,00 7,70 9,00 10,60 14,20 17,40 3,00 3,55 4,80 5,90
Current in heating (1p 240V / 3p 415) A 3,30 5,75 7,40 8,60 10,10 13,60 16,70 2,90 3,40 4,65 5,65
Outdoor air flow (Cool) m³/min 34,1 42,0 42,0 62,0 76,0 86,0 89,0 62,0 76,0 86,0 89,0
Outdoor air flow (Heat) m³/min 36,4 42,0 42,0 66,0 70,0 78,0 83,0 66,0 70,0 78,0 83,0
Outdoor sound pressure (Cool - Hi) dB(A) 43 46 47 48 52 55 56 48 52 55 56
Outdoor sound pressure (Heat - Hi) dB(A) 44 48 50 50 52 55 56 50 52 55 56
Outdoor sound power (Cool -Hi) dB(A) 62 64 65 65 69 73 74 65 69 73 74
Outdoor sound power (Heat -Hi) dB(A) 64 67 69 67 69 73 74 67 69 73 74
Outdoor dimension (Height) mm 695 695 695 996 996 996 996 996 996 996 996
Outdoor dimension (Width) mm 875 875 875 980 980 980 980 980 980 980 980
Outdoor dimension (Depth) mm 320 320 320 370 370 370 370 370 370 370 370
Outdoor net weight kg 42 42 43 66 84 86 86 66 82 84 84
Piping diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) (5) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Piping diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70) (6) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5 ~ 100 5 ~ 100 5 ~ 100 5 ~ 60 5 ~ 100 5 ~ 100 5 ~ 100
Elevation difference (in/out) (7) m 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30
Pre-charged pipe length m 30 30 30 30 30 30 30 30 30 30 30
Additional gas amount g/m 15 15 15 30 40 40 40 30 40 40 40
Refrigerant (R32) / CO2 Eq. kg / T 1,13 / 0,76 1,13 / 0,76 1,15 / 0,78 1,95 / 1,32 2,70 / 1,82 3,00 / 2,03 3,00 / 2,03 1,95 / 1,32 2,70 / 1,82 3,00 / 2,03 3,00 / 2,03
Operating range (Cool - Min) °C -15 -15 -15 -15 -20 (8) -20 (8) -20 (8) -15 -20 (8) -20 (8) -20 (8)
Operating range (Cool - Max) °C +46 +46 +46 +52 +52 +52 +52 +52 +52 +52 +52
Operating range (Heat - Min) °C -20 -20 -20 -20 -20 -20 -20 -20 -20 -20 -20
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24 +24 +24 +24 +24

1) EER and COP calculation is based in accordance to EN14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηs,c / ηs,h values is calculated based on EN 14825.
3) Factory setting.
4) The sound pressure of the units shows the value measured of the position 1,5m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit.
7) Outdoor unit located lower / outdoor unit located higher.
8) Pipe length up to 30m.

* Recommended fuse for the indoor 3A.
** Above values are in the case of nanoe™ X OFF.

Complementary products