Free Multi Wall TZ · R32

Multi TZ System · R32

Bringing higher level of comfort with lower energy cost, improving the quality of the indoor air, and creating a relaxing environment.

The air conditioning connects with the future

Specifications

See all
Free Multi Wall TZ · R32 SINGLE PHASE
4.10 kW 5.00 kW 5.20 kW
Outdoor unit CU-2TZ41TBE CU-2TZ50TBE CU-3TZ52TBE
Indoor nominal capacity (Min ~ Max) kW 3,2 ~ 6,0kW 3,2 ~ 7,7kW 4,5 ~ 9,5kW
Cooling capacity (Nominal) kW 4,10 5,00 5,20
Cooling capacity (Min) kW 1,50 1,50 1,80
Cooling capacity (Max) kW 4,70 5,40 6,60
EER (Nominal) (1) W/W 4,14 3,85 4,52
EER (Min) (1) W/W 5,56 5,56 3,67
EER (Max) (1) W/W 3,41 3,33 5,00
SEER (2) 7,10 A++ 7,00 A++ 7,60 A++
Pdesign (cooling) kW 4,10 5,00 5,20
Input power cooling (Nominal) kW 0,99 1,30 1,15
Input power cooling (Min) kW 0,27 0,27 0,36
Input power cooling (Max) kW 1,38 1,62 1,80
Annual energy consumption cooling (3) kWh/a 202 250 239
Heating capacity (Nominal) kW 4,40 5,70 6,80
Heating capacity (Min) kW 1,10 1,10 1,60
Heating capacity (Max) kW 6,30 6,40 7,50
Heating capacity at -7°C kW
COP (Nominal) (1) W/W 4,44 4,35 4,28
COP (Min) (1) W/W 5,00 5,00 3,87
COP (Max) (1) W/W 3,54 3,62 5,00
SCOP (2) 4,30 A+ 4,20 A+ 4,20 A+
Pdesign at -10°C kW 3,50 4,50 5,00
Input power heating (Nominal) kW 0,99 1,31 1,59
Input power heating (Min) kW 0,22 0,22 0,32
Input power heating (Max) kW 1,78 1,77 1,94
Annual energy consumption heating (3) kWh/a 1.139 1.500 1.667
Power supply (Voltage) V 230 230 230
Current cooling A 4,60 6,00 5,30
Current heating A 4,60 6,00 7,30
Outdoor sound pressure (Cool - Hi) (4) dB(A) 48 50 48
Outdoor sound pressure (Heat - Hi) (4) dB(A) 50 52 48
Outdoor dimension (Height) (5) mm 542 542 795
Outdoor dimension (Width) (5) mm 780 780 875
Outdoor dimension (Depth) (5) mm 289 289 320
Outdoor net weight kg 35 35 71
Piping diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Piping diameter (Gas) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe length range total m 6 ~ 30 6 ~ 30 6 ~ 50
Pipe length range to one unit m 3 ~ 20 3 ~ 20 3 ~ 25
Elevation difference (in/out) m 10 10 15
Pre-charged pipe length m 20 20 30
Additional gas amount g/m 15 15 20
Refrigerant (R32) / CO2 Eq. kg / T 0,9 / 0,6075 0,9 / 0,6075 2,1 / 1,4175
Operating range (Cool - Min) °C -10 -10 -10
Operating range (Cool - Max) °C +46 +46 +46
Operating range (Heat - Min) °C -15 -15 -15
Operating range (Heat - Max) °C +24 +24 +24

1) EER and COP calculation is based in accordance to EN14511.
2) Energy Label Scale from A+++ to D.
3) The annual energy consumption is calculated in accordance to EU/626/2011.
4) The sound pressure of the units shows the value measured of a position 1m in front and 1m in rear side of the main body. The sound pressure is measured in accordance with JISC9612.
5) Add 70 or 95mm for piping port.