MT/LT TYPE 1000VF8A - 16kW / 8kW THREE PHASE
16.0 kW
Standard model OCU-CR1000VF8A
Anti corrosion coating model OCU-CR1000VF8ASL
Type (MT: medium temp. LT: low temp.) MT (16kW) / LT (8kW)
Power supply (Voltage) V 380 / 400 / 415
Power supply (Phase) Three phase
Power supply (Frequency) Hz 50
Cooling capacity at ET -10°C AT 32°C kW 15,10
Cooling capacity at ET -35°C AT 32°C kW 8,00
SEPR cooling at ET -10°C AT 32°C 2,86
SEPR freezing at ET -35°C AT 32°C 1,49
Annual electricity consumption at ET -10°C AT 32°C kWh/a 32.409
Annual electricity consumption at ET -35°C AT 32°C kWh/a 39.985
Evaporator connection Multiple
Evaporation temperature (Min) °C -45
Evaporation temperature (Max) °C -5
Ambient temperature (Min) °C -20
Ambient temperature (Max) °C +43
Refrigerant R744
Design pressure liquid line Mpa 8
Design pressure suction line Mpa 8
User system external alarm. Digital input. Non-voltage contact Yes
Liquid tube electromagnetic valve Vac 220 / 230 / 240
Showcase operation ON/OFF signal. Digital input. Non-voltage contact Yes
Modbus communication line (RS485) Ports Yes
Type of compressors 2- stage rotary
Dimension (Height) mm 1.941
Dimension (Width) mm 890
Dimension (Depth) mm 890 
Net weight kg 320
Piping diameter (Suction) (1) Inch (mm) ¾ (19,05)
Piping diameter (Liquid) (1) Inch (mm) ⅝ (15,88)
Length of connection piping m 100 (2)
PED CAT ΙΙ
Air flow m³/min 220
External static pressure Pa 58
Heat recovery port Yes
Standard performance .
Ambient temperature °C 32
Evaporating temperature (MT) °C -10
Evaporating temperature (LT) °C -35
Cooling capacity (MT) kW 15,10
Cooling capacity (LT) kW 8,00
Power consumption (MT) kW 8,20
Power consumption (LT) kW 7,57
Nominal load ampere (MT) A 12,60
Nominal load ampere (LT) A 11,60
Sound pressure (MT) dB(A) 36,0 (3)
Sound pressure (LT) dB(A) 36,0 (3)
Drier filter liquid line, Ø6,35mm D-152T / DCY-P12
Drier filter liquid line, Ø15,88mm D-155T / DCY-P8 Yes (included)
Suction filter, Ø19,05mm (outer Ø welding) S-008T / S-008T1 Yes (included)

(1) These diameters correspond to the output of the unit. The required diameter must be calculated with Refrigeration designer available on PRO Club.
(2) PZ-68S (refrigeration oil) must be added if >50m.
(3) ET -10°C, 60 S-1, 10m from product
.