MT TYPE 1000VF8 - 15kW

Condensing units with natural refrigerant

The new environmentally friendly CO2 condensing units for commercial refrigeration.

With Panasonic condensing units you can expect: energy savings, low noise levels, light weight, low refrigerant charge, low installation cost and low costs on servicing.

The new environmentally friendly CO2 condensing units for commercial refrigeration

Panasonic Cold Chain - CR Series - Highlights

A sustainable refrigeration systems in your food retail

Specifications

See all
MT TYPE 1000VF8 - 15kW THREE PHASE
15.0 kW
Standard model OCU-CR1000VF8
Anti corrosion coating model OCU-CR1000VF8SL
Type (MT: medium temp. LT: low temp.) MT (15kW)
Power supply (Voltage) V 380 / 400 / 415
Power supply (Phase) Three phase
Power supply (Frequency) Hz 50
Cooling capacity at ET -10°C AT 32°C kW 14,00
Cooling capacity at ET -35°C AT 32°C kW
SEPR cooling at ET -10°C AT 32°C 2,62
SEPR freezing at ET -35°C AT 32°C
Annual electricity consumption at ET -10°C AT 32°C kWh/a 32.815
Annual electricity consumption at ET -35°C AT 32°C kWh/a
Evaporator connection Multiple
Evaporation temperature (Min) °C -20
Evaporation temperature (Max) °C -5
Ambient temperature (Min) °C -20
Ambient temperature (Max) °C +43
Refrigerant R744
Design pressure liquid line Mpa 8
Design pressure suction line Mpa 8
User system external alarm. Digital input. Non-voltage contact Yes
Liquid tube electromagnetic valve Vac 220 / 230 / 240
Showcase operation ON/OFF signal. Digital input. Non-voltage contact Yes
Modbus communication line (RS485) Ports Yes
Type of compressors 2- stage rotary
Dimension (Height) mm 1.941
Dimension (Width) mm 890
Dimension (Depth) mm 890
Net weight kg 293
Piping diameter (Suction) (1) Inch (mm) ¾ (19,05)
Piping diameter (Liquid) (1) Inch (mm) ⅝ (15,88)
Length of connection piping m 100 (2)
PED CAT ΙΙ
Air flow m³/min 220
External static pressure Pa 58
Heat recovery port
Standard performance .
Ambient temperature °C 32
Evaporating temperature (MT) °C -10
Evaporating temperature (LT) °C
Cooling capacity (MT) kW 14,00
Cooling capacity (LT) kW
Power consumption (MT) kW 8,20
Power consumption (LT) kW
Nominal load ampere (MT) A 12,60
Nominal load ampere (LT) A
Sound pressure (MT) dB(A) 36,0 (3)
Sound pressure (LT) dB(A)
Drier filter liquid line, Ø6,35mm D-152T / DCY-P12
Drier filter liquid line, Ø15,88mm D-155T / DCY-P8 Yes (included)
Suction filter, Ø19,05mm (outer Ø welding) S-008T / S-008T1 Yes (included)

(1) These diameters correspond to the output of the unit. The required diameter must be calculated with Refrigeration designer available on PRO Club.
(2) PZ-68S (refrigeration oil) must be added if >50m.
(3) ET -10°C, 60 S-1, 10m from product
.

Complementary products