Mini ECOi LZ2 Series 8 and 10HP - R32

Mini ECOi LZ2 Series 8 and 10HP - R32

Introducing widest range of R32 Mini VRF.

Perfect fit for small to medium size projects.

8 and 10HP LZ2 Mini VRF units bring in the total benefits of a VRF system in a smaller application. You can enjoy advanced individual and central VRF control options including the revolutionary Panasonic AC Smart Cloud and AC Service Cloud.

For the most difficult conditions.

New ECOi LZ2 series are able to operate at the hardest conditions from -20°C up to +52°C providing continuous and efficient, heating and cooling for your space all year long.

Technical focus.

Bringing nature’s balance indoors

Specifications

See all
Mini ECOi LZ2 Series 8 and 10HP - R32 THREE PHASE
8 HP 10 HP
Outdoor unit U-8LZ2E8 U-10LZ2E8
Power supply (Voltage) V 380 - 400-415 380 - 400 - 415
Power supply (Phase) Three phase Three phase
Power supply (Frequency) Hz 50 50
Cooling capacity (Nominal) kW 22,4 28,0
EER (1) W/W 3,84 3,47
Current cooling (1p 220V / 3p 380) A 9,73 13,2
Current cooling (1p 230V / 3p 400) A 9,25 12,5
Current cooling (1p 240V / 3p 415) A 8,91 12,1
Input power cooling kW 5,83 8,07
Heating capacity (Nominal) kW 25,0 28,0
COP (1) W/W 4,30 4,47
Current heating (1p 220V / 3p 380) A 9,81 10,5
Current heating (1p 230V / 3p 400) A 9,32 9,93
Current heating (1p 240V / 3p 415) A 8,98 9,57
Input power heating kW 5,81 6,26
Starting current A 1,0 1,0
Maximum current A 13,7 19,5
Maximum input power (1p 220V / 3p 380) kW 8,21 11,9
Maximum input power (1p 230V / 3p 400) kW 8,64 12,6
Maximum input power (1p 240V / 3p 415) kW 8,96 13,0
Maximum number of connectable indoor units (2) 16 16
External static pressure Pa 0 ~ 35 0 ~ 35
Air flow m³/min 158 167
Sound pressure (Cool) dB(A) 59,0 60,0
Sound pressure (Cool silent 1) dB(A) 56 57
Sound pressure (Cool silent 2) dB(A) 54 55
Sound pressure (Cool silent 3) dB(A) 52 53
Sound pressure (Cool silent 4) dB(A) 50 50
Sound power (Cool) dB(A) 72 74
Dimension (Height) mm 1.500 1.500
Dimension (Width) mm 980 980
Dimension (Depth) mm 370 370
Net weight kg 125 126
Piping diameter (Liquid) Inch (mm) 3/8 (9,52) 3/8 (9,52)
Piping diameter (Gas) Inch (mm) 3/4 (19,05) 7/8 (22,22)
Maximum piping length total m 300 300
Elevation difference (in/out) (outdoor unit upper) m 50 50
Elevation difference (in/out) (outdoor unit lower) m 40 40
Refrigerant (R32) / CO2 Eq. kg / T 4,9 5,1
Maximum allowable indoor / outdoor capacity ratio (3) % 50 ~ 150 (130) 50 ~ 150 (130)
Operating range (Cool - Min) °C -10 -10
Operating range (Cool - Max) °C 52 52
Operating range (Heat - Min) °C -20 -20
Operating range (Heat - Max) °C 18 18
ErP data (4) U-8LZ2E8 U-10LZ2E8
SEER (5) 7,56 7,08
ηs,c 299,4% 280,2%
SCOP (5) 4,59 4,60
ηs,h 180,6% 181,0%
(1) EER and COP calculation is based on EN 14511.
(2) The number in parenthesis indicates maximum number of connectable indoor unit in case of 1,5kW indoor units connection.
(3) The number in parenthesis indicates maximum allowed indoor / outdoor capacity ratio in case of 1,5kW indoor units connection.
(4) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for U2 type 4 way 90x90 cassette indoor units. Eurovent certified.
(5) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.