Mini ECOi LZ2 Series 4 to 6HP - R32

Mini ECOi LZ2 Series 4 to 6HP - R32

Outstanding efficiency in a compact body and continuous operation even at extreme ambient temperatures.

Minimum environmental impact.

Panasonic has designed the LZ2 series in order to minimize the environmental impact of the system. Low GWP refrigerant R32 and highest efficiency levels ensure this through the total operational lifetime.

For the most challenging spaces.

The new Mini ECOi LZ2 R32 VRF system is the ideal solution to fit into any application thanks to its compact design and long piping lengths.

Technical focus.

Bringing nature’s balance indoors

Specifications

See all
Mini ECOi LZ2 Series 4 to 6HP - R32 SINGLE PHASE THREE PHASE
4 HP 5 HP 6 HP 4 HP 5 HP 6 HP
Outdoor unit U-4LZ2E5 U-5LZ2E5 U-6LZ2E5 U-4LZ2E8 U-5LZ2E8 U-6LZ2E8
Power supply (Voltage) V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Power supply (Phase) Single phase Single phase Single phase Three phase Three phase Three phase
Power supply (Frequency) Hz 50 50 50 50 50 50
Cooling capacity (Nominal) kW 12,1 14,0 15,5 12,1 14,0 15,5
EER (1) W/W 4,53 4,12 3,88 4,53 4,12 3,88
Current cooling (1p 220V / 3p 380) A 13,30 16,90 19,60 4,37 5,50 6,44
Current cooling (1p 230V / 3p 400) A 12,80 16,20 18,70 4,15 5,23 6,12
Current cooling (1p 240V / 3p 415) A 12,20 15,50 18,00 4,00 5,04 5,89
Input power cooling kW 2,67 3,40 4,00 2,67 3,40 4,00
Heating capacity (Nominal) kW 12,5 16,0 16,5 12,5 16,0 16,5
COP (1) W/W 5,27 4,71 4,42 5,27 4,71 4,42
Current heating (1p 220V / 3p 380) A 12,00 16,90 18,50 3,91 5,50 6,02
Current heating (1p 230V / 3p 400) A 11,40 16,20 17,70 3,71 5,22 5,72
Current heating (1p 240V / 3p 415) A 11,00 15,50 17,00 3,58 5,03 5,51
Input power heating kW 2,37 3,40 3,73 2,37 3,40 3,73
Starting current A 1,0 1,0 1,0 1,0 1,0 1,0
Maximum current A 19,6 23,7 26,5 7,2 9,2 9,9
Maximum input power (1p 220V / 3p 380) kW 3,92 4,76 5,41 4,40 5,69 6,15
Maximum input power (1p 230V / 3p 400) kW 4,10 4,98 5,66 4,63 5,99 6,47
Maximum input power (1p 240V / 3p 415) kW 4,28 5,19 5,90 4,80 6,22 6,72
Maximum number of connectable indoor units (2) 7 (10) 8 (12) 9 (12) 7 (10) 8 (12) 9 (12)
External static pressure Pa 0 ~ 35 0 ~ 35 0 ~ 35 0 ~ 35 0 ~ 35 0 ~ 35
Air flow m³/min 69 72 74 69 72 74
Sound pressure (Cool) dB(A) 52 53 54 52 53 54
Sound pressure (Cool silent 1) dB(A) 49 50 51 49 50 51
Sound pressure (Cool silent 2) dB(A) 47 48 49 47 48 49
Sound pressure (Cool silent 3) dB(A) 45 46 47 45 46 47
Sound pressure (Cool silent 4) dB(A) 45 45 45 45 45 45
Sound pressure (Heat) dB(A) 54 56 56 54 56 56
Sound power (Cool) dB(A) 69 70 72 69 70 72
Sound power (Heat) dB(A) 72 74 75 72 74 75
Dimension (Height) mm 996 996 996 996 996 996
Dimension (Width) mm 980 980 980 980 980 980
Dimension (Depth) mm 370 370 370 370 370 370
Net weight kg 94 94 94 94 94 94
Piping diameter (Liquid) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Piping diameter (Gas) Inch (mm) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Maximum piping length total m 180 180 180 180 180 180
Elevation difference (in/out) (outdoor unit upper) m 50 50 50 50 50 50
Elevation difference (in/out) (outdoor unit lower) m 40 40 40 40 40 40
Refrigerant (R32) / CO2 Eq. kg / T 2,7 2,7 2,7 2,7 2,7 2,7
Maximum allowable indoor / outdoor capacity ratio (3) % 50 ~ 150 (130) 50 ~ 150 (130) 50 ~ 150 (130) 50 ~ 150 (130) 50 ~ 150 (130) 50 ~ 150 (130)
Operating range (Cool - Min) °C -10 -10 -10 -10 -10 -10
Operating range (Cool - Max) °C 52 52 52 52 52 52
Operating range (Heat - Min) °C -20 -20 -20 -20 -20 -20
Operating range (Heat - Max) °C 18 18 18 18 18 18
ErP data (4) U-4LZ2E5 U-5LZ2E5 U-6LZ2E5 U-4LZ2E8 U-5LZ2E8 U-6LZ2E8
SEER (5) 8,50 8,12 7,71 8,50 8,12 7,71
ηs,c 337,0% 321,8% 305,4% 337,0% 321,8% 305,4%
SCOP (5) 5,05 4,61 4,59 5,05 4,61 4,59
ηs,h 199,0% 181,4% 180,6% 199,0% 181,4% 180,6%
(1) EER and COP calculation is based on EN 14511.
(2) The number in parenthesis indicates maximum number of connectable indoor unit in case of 1,5kW indoor units connection.
(3) The number in parenthesis indicates maximum allowed indoor / outdoor capacity ratio in case of 1,5kW indoor units connection.
(4) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for U2 type 4 way 90x90 cassette indoor units. Eurovent certified.
(5) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.