Hydraulic Split L Generation 1 phase. 2 zones · R290

Aquarea High Performance Hydraulic Split All in One L Generation Single phase

A revolution in design, efficiency, connectivity and sustainability.
Aquarea L Generation is engineered with industry leading R290 natural refrigerant with GWP 3. It is the perfect solution for renovations, where a high water outlet temperature is required or homes looking for avant-garde heat pump with natural refrigerant.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit. The All in One model maintains its compactness with its encroachment of only 599 x 602mm, comparable to a household appliance.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.

Owning an Aquarea?

Specifications

See all
Hydraulic Split L Generation 1 phase. 2 zones · R290 SINGLE PHASE
5 kW 7 kW 9 kW
Kit KIT-ADC05L3E5B KIT-ADC07L3E5B KIT-ADC09L3E5B
Heating capacity (A +7°C, W 35°C) kW 5,00 7,00 9,00
COP (A +7°C, W 35°C) 5,05 4,93 4,55
Heating capacity (A +7°C, W 55°C) kW 5,00 7,00 8,90
COP (A +7°C, W 55°C) 3,07 2,98 3,03
Heating capacity (A +2°C, W 35°C) kW 5,00 6,85 7,00
COP (A +2°C, W 35°C) 3,52 3,43 3,41
Heating capacity (A +2°C, W 55°C) kW 5,00 6,25 7,00
COP (A +2°C, W 55°C) 2,34 2,34 2,41
Heating capacity (A -7°C, W 35°C) kW 5,00 5,80 7,00
COP (A -7°C, W 35°C) 3,01 3,01 2,80
Heating capacity (A -7°C, W 55°C) kW 5,00 5,80 7,00
COP (A -7°C, W 55°C) 2,12 2,12 2,13
Cooling capacity (A 35°C, W 7°C) kW 5,00 7,00 8,20
EER (A 35°C, W 7°C) 3,23 3,03 2,82
Cooling capacity (A 35°C, W 18°C) kW 5,00 7,00 9,00
EER (A 35°C, W 18°C) 5,00 4,73 4,19
Heating average climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 5,06 / 3,63 4,96 / 3,62 4,84 / 3,67
Heating average climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 200 / 142 195 / 142 190 / 144
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 6,00 / 4,27 6,31 / 4,52 6,44 / 4,50
Heating warm climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 237 / 168 249 / 178 255 / 177
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,25 / 3,28 4,25 / 3,29 4,31 / 3,33
Heating cold climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 167 / 128 167 / 129 170 / 130
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++ A++ / A++
Indoor unit WH-ADC0509L3E5B WH-ADC0509L3E5B WH-ADC0509L3E5B
Indoor sound pressure (Heat) dB(A) 28 28 28
Indoor sound pressure (Cool) dB(A) 28 28 28
Indoor dimension (Height) mm 1.642 1.642 1.642
Indoor dimension (Width) mm 599 599 599
Indoor dimension (Depth) mm 602 602 602
Indoor net weight kg 101 101 101
Water pipe connector (room) Inch 1-1/4 1-1/4 1-1/4
Water pipe connector (shower) Inch 3/4 3/4 3/4
A class pump (Number of speeds) Variable Speed Variable Speed Variable Speed
A class pump (Input power Min) W 30 30 30
A class pump (Input power Max) W 145 145 145
Heating water flow (∆T=5 K. 35°C) L/min 14,3 20,1 25,8
Water volume L 185 185 185
Maximum DHW temperature °C 65 65 65
Material inside tank Stainless steel Stainless steel Stainless steel
Tapping profile according EN16147 L L L
DHW tank ERP average climate efficiency rating (2) A+ to F A+ A+ A+
DHW tank ERP warm climate efficiency rating (2) A+ to F A+ A+ A+
DHW tank ERP cold climate efficiency rating (2) A+ to F A A A
DHW tank ERP average climate η ηwh % 146 146 146
DHW tank ERP average climate COPdHW COPdHW 3,60 3,60 3,60
DHW tank ERP warm climate η ηwh % 160 160 160
DHW tank ERP warm climate COPdHW COPdHW 4,00 4,00 4,00
DHW tank ERP cold climate η ηwh % 112 112 112
DHW tank ERP cold climate COPdHW COPdHW 2,80 2,80 2,80
Outdoor unit WH-WDG05LE5 WH-WDG07LE5 WH-WDG09LE5
Outdoor sound power (Heat) (3) dB(A) 52 53 54
Outdoor dimension (Height) mm 996 996 996
Outdoor dimension (Width) mm 980 980 980
Outdoor dimension (Depth) mm 430 430 430
Outdoor net weight kg 98 98 97
Refrigerant (R290) / CO2 Eq. kg / T 0,96 / 0,003 0,96 / 0,003 1,00 / 0,003
Water pipe connector (indoor units) Inch 1 1 1
Water pipe connector (outdoor units) Inch 1 1 1
Pipe length range standard m 5 5 5
Pipe length range maximum m 30 30 30
Elevation difference (in/out) m 10 10 10
Operation range - Outdoor ambient (Heat) °C -25 ~ +35 -25 ~ +35 -25 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43
Water outlet (Heat) °C 20 ~ 75 20 ~ 75 20 ~ 75
Water outlet (Cool) °C 5 ~ 20 5 ~ 20 5 ~ 20
Electrical information WH-ADC0509L3E5B WH-ADC0509L3E5B WH-ADC0509L3E5B
Electric backup heater kW 3,00 3,00 3,00
Recommended RCD, supply 1 A 25 25 25
Recommended RCD, supply 2 A 16 16 16
Recommended minimum cable size, supply 1 (4) mm² 3x2,5 3x2,5 3x2,5
Recommended minimum cable size, supply 2 (4) mm² 3x1,5 3x1,5 3x1,5
(1) Scale from A+++ to D.
(2) Scale from A+ to F.
(3) The sound power level is measured with accordance to EN12102 under conditions of the EN14825 (part load).
(4) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.

Complementary products