Fan coils - Ducted (EC)

New range of fan coils. Designed to fit with your environment and enhance comfort

Panasonic introduces the new range of fan coils.

The key to this range is to provide performance and comfort and the ability to fit seamlessly within your environment.

Designed with user in mind, perfectly designed to adapt to any installation. Providing comfort to hotels, shops, restaurants, offices or residential applications.

Technical focus.
· Cooling capacity from 0,5 to 9,6kW
· Heating capacity from 0,6 to 13,6kW
· Low energy consumption EC fan(s)

Main features and accessories.
· 2 and 4-pipe configurations
· Left or right hand arrangements
· Can be installed both horizontally and vertically*
· Ease of installation
· Very low acoustic levels
· 2 way or 3 way ON/OFF valves
· Auxiliary drain pan
· Air intake with removable grid
· G2 filter

*PAW-FC2E-F040 and PAW-FC4E-F040 may only be installed horizontally.

The reasons to choose Panasonic as your partner

Explore the new range of fan coils

Specifications

See all
Fan coils - Ducted (EC) SINGLE PHASE
2.1 kW 2.4 kW 3.1 kW 4.2 kW 5.0 kW 5.2 kW 6.9 kW 8.8 kW 9.2 kW
2-pipe - Left connection PAW-FC2E-D010L PAW-FC2E-D020L PAW-FC2E-D030L PAW-FC2E-D040L PAW-FC2E-D050L PAW-FC2E-D060L PAW-FC2E-D070L PAW-FC2E-D080L PAW-FC2E-F040L
2-pipe - Right connection PAW-FC2E-D010R PAW-FC2E-D020R PAW-FC2E-D030R PAW-FC2E-D040R PAW-FC2E-D050R PAW-FC2E-D060R PAW-FC2E-D070R PAW-FC2E-D080R PAW-FC2E-F040R
Total cooling capacity - 2-pipe (Lo) (1) kW 0,6 0,6 0,9 1,3 1,3 2,0 2,7 5,1 3,6
Total cooling capacity - 2-pipe (Med) (1) kW 1,2 1,4 2,1 2,9 4,0 4,5 5,9 6,5 6,6
Total cooling capacity - 2-pipe (Hi) (1) kW 2,1 2,4 3,1 4,2 5,0 5,2 6,9 8,8 9,2
Sensible cooling capacity - 2-pipe (Lo) (1) kW 0,5 0,5 0,6 1,0 1,1 1,4 2,0 3,7 2,9
Sensible cooling capacity - 2-pipe (Med) (1) kW 1,1 1,1 1,6 2,1 3,0 3,5 4,3 4,8 6,1
Sensible cooling capacity - 2-pipe (Hi) (1) kW 1,9 1,9 2,4 3,0 3,7 4,0 5,2 6,6 9,1
Water flow - 2-pipe (Cooling) (Lo) l/h 107 110 148 230 231 341 463 879 627
Water flow - 2-pipe (Cooling) (Med) l/h 210 237 354 506 685 767 1.008 1.111 1.142
Water flow - 2-pipe (Cooling) (Hi) l/h 356 406 532 722 743 800 1.098 1.254 1.575
Water pressure drop - 2-pipe (Cooling) (Lo) kPa 8,2 1,5 5,0 6,4 4,9 7,8 3,0 14,1 10,6
Water pressure drop - 2-pipe (Cooling) (Med) kPa 28,2 4,6 20,5 24,4 35,1 35,8 14,0 21,4 51,2
Water pressure drop - 2-pipe (Cooling) (Hi) kPa 76,9 11,0 42,1 46,3 41,0 38,8 16,6 26,6 93,8
Heating capacity - 2-pipe (Lo) (2) kW 0,8 0,9 1,0 1,4 1,7 2,3 3,8 6,2 4,4
Heating capacity - 2-pipe (Med) (2) kW 1,6 1,9 2,2 3,0 5,2 5,9 7,3 8,0 8,3
Heating capacity - 2-pipe (Hi) (2) kW 2,9 3,3 3,4 5,3 5,5 6,1 8,2 9,3 11,8
4-pipe - Left connection PAW-FC4E-D010L PAW-FC4E-D020L PAW-FC4E-D030L PAW-FC4E-D040L PAW-FC4E-D050L PAW-FC4E-D060L PAW-FC4E-D070L PAW-FC4E-D080L PAW-FC4E-F040L
4-pipe - Right connection PAW-FC4E-D010R PAW-FC4E-D020R PAW-FC4E-D030R PAW-FC4E-D040R PAW-FC4E-D050R PAW-FC4E-D060R PAW-FC4E-D070R PAW-FC4E-D080R PAW-FC4E-F040R
Total cooling capacity - 4-pipe (Lo) (1) kW 0,5 0,6 0,8 1,2 1,2 1,8 2,6 5,0 3,3
Total cooling capacity - 4-pipe (Med) (1) kW 1,1 1,2 1,9 2,7 3,6 4,1 5,1 6,2 6,4
Total cooling capacity - 4-pipe (Hi) (1) kW 1,9 2,2 2,9 4,0 4,6 4,9 6,4 9,6 8,8
Sensible cooling capacity - 4-pipe (Lo) (1) kW 0,4 0,4 0,6 0,9 1,0 1,2 1,9 3,6 2,7
Sensible cooling capacity - 4-pipe (Med) (1) kW 0,9 1,0 1,5 1,9 2,8 3,2 3,8 4,6 5,6
Sensible cooling capacity - 4-pipe (Hi) (1) kW 1,7 1,8 2,2 2,8 3,5 3,8 4,8 7,2 8,0
Water flow - 4-pipe (Cooling) (Lo) l/h 92 97 129 205 212 306 443 855 567
Water flow - 4-pipe (Cooling) (Med) l/h 185 206 321 457 625 707 886 1.070 1.093
Water flow - 4-pipe (Cooling) (Hi) l/h 327 375 493 681 686 749 977 1.242 1.511
Water pressure drop - 4-pipe (Cooling) (Lo) kPa 5,8 1,3 4,0 6,3 2,5 5,1 3,5 22,9 10,0
Water pressure drop - 4-pipe (Cooling) (Med) kPa 20,1 3,7 9,2 29,6 17,9 24,3 13,6 33,9 47,2
Water pressure drop - 4-pipe (Cooling) (Hi) kPa 59,2 9,7 19,7 60,1 21,3 27,2 16,5 44,3 86,7
Heating capacity - 4-pipe (Lo) (2) kW 0,4 0,6 1,0 1,2 1,6 1,4 2,5 4,5 2,5
Heating capacity - 4-pipe (Med) (2) kW 0,8 0,9 1,4 2,0 2,4 2,9 3,4 5,9 4,5
Heating capacity - 4-pipe (Hi) (2) kW 1,4 1,5 1,8 2,8 2,5 3,1 3,6 6,9 6,2
Water flow (Heating) (Lo) l/h 76 95 166 204 267 233 434 767 432
Water flow (Heating) (Med) l/h 140 161 243 350 416 503 583 1.011 783
Water flow (Heating) (Hi) l/h 235 255 304 483 438 531 614 1.194 1.065
Water pressure drop (Heating) (Lo) kPa 1,8 1,4 5,3 15,6 11,9 11,5 61,5 42,1 30,6
Water pressure drop (Heating) (Med) kPa 4,0 3,8 9,7 41,8 26,3 43,6 103,8 69,7 107,6
Water pressure drop (Heating) (Hi) kPa 8,4 9,4 14,1 76,3 28,9 48,1 113,9 95,1 214,8
Sound levels . . . . . . . . .
Sound power (Lo) dB(A) 34 34 31 29 30 32 40 51 42
Sound power (Med) dB(A) 47 47 50 44 51 54 54 56 58
Sound power (Hi) dB(A) 60 60 59 52 57 58 59 64 68*
Sound pressure (Lo) (3) dB(A) 25 25 22 20 21 23 31 42 23
Sound pressure (Med) (3) dB(A) 38 38 41 35 42 45 45 47 39
Sound pressure (Hi) (3) dB(A) 51 51 50 43 48 49 50 55 52
Fan data . . . . . . . . .
Number of fans 1 1 1 2 2 2 2 3 1
Air flow - 2-pipe (Lo) m³/h 108 98 145 170 203 245 350 685 592
Air flow - 2-pipe (Med) m³/h 228 234 380 412 645 737 850 927 1.284
Air flow - 2-pipe (Hi) m³/h 417 413 585 678 816 912 1050 1.398 1.935
Air flow - 4-pipe (Lo) m³/h 91 84 123 148 185 205 329 660 523
Air flow - 4-pipe (Med) m³/h 199 200 342 369 587 668 798 884 1.222
Air flow - 4-pipe (Hi) m³/h 379 380 540 627 646 716 894 1.079 1.864
Maximum external pressure Pa 75 75 75 105 70 105 115 115 190
Filter G2 G2 G2 G2 G2 G2 G2 G2 G2
Electrical data . . . . . . . . .
Power supply (Voltage) V 230 230 230 230 230 230 230 230 230
Power supply (Phase) Single phase Single phase Single phase Single phase Single phase Single phase Single phase Single phase Single phase
Power supply (Frequency) Hz 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60
Power consumption - 2-pipe (Lo) W 5 5 4 2 4 2 11 23 11
Power consumption - 2-pipe (Med) W 11 13 16 13 24 30 44 42 62
Power consumption - 2-pipe (Hi) W 41 41 42 43 46 54 77 108 197
Power consumption - 4-pipe (Lo) W 5 5 6 2 2 2 11 22 11
Power consumption - 4-pipe (Med) W 11 13 15 12 23 28 43 41 60
Power consumption - 4-pipe (Hi) W 39 40 40 42 44 52 75 116 188
Fan coils water connections . . . . . . . . .
Type of water connections Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded
Water connections - 2-pipe Inch 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4
Water connections - 4-pipe (Cooling) Inch 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4
Water connections - 4-pipe (Heating) Inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Dimensions and weight . . . . . . . . .
Dimension (Height) mm 220 220 220 220 220 220 220 220 223
Dimension (Width) mm 570 570 730 938 1.122 1.307 1.121 1.316 1.233
Dimension (Depth) mm 430 430 430 430 430 430 530 530 653
Weight - 2-pipe kg 13 13 15 20 22 26 27 38 19
Weight - 4-pipe kg 14 14 16 22 24 28 29 40 19

1) According to Eurovent standard. Air: 27°C DB / 19°C WB. Water in/out: 7°C / 12°C.
2) Air: 20°C. Water in/out: 50°C / 45°C.
3) The sound pressure levels are based on (NR) characteristics of a room having volume of 100m³ with reverberation of 0,5 seconds.
* The sound power levels indicated are from return and radiated measurements.
Values indicated are for 0Pa external static pressure, for additional pressure characteristics, please refer the technical data manual.