Fan coils - Ducted (AC)

New range of fan coils. Designed to fit with your environment and enhance comfort

Panasonic introduces the new range of fan coils.

The key to this range is to provide performance and comfort and the ability to fit seamlessly within your environment.

Designed with user in mind, perfectly designed to adapt to any installation. Providing comfort to hotels, shops, restaurants, offices or residential applications.

Technical focus.
· Cooling capacity from 0,7 to 8,1kW
· Heating capacity from 0,7 to 10,3kW
· 5-speed AC fan motor(s)

Main features and accessories.
· 2 and 4-pipe configurations
· Left or right hand arrangements
· Ease of installation
· Very low acoustic levels
· 2 way or 3 way ON/OFF valves
· Auxiliary drain pan
· Air intake with removable grid
· G2 filter

The reasons to choose Panasonic as your partner

Explore the new range of fan coils

Specifications

See all
Fan coils - Ducted (AC) SINGLE PHASE
1.5 kW 1.7 kW 2.5 kW 3.2 kW 4.6 kW 5.8 kW 7.3 kW 8.1 kW
2-pipe - Left connection PAW-FC2A-D010L PAW-FC2A-D020L PAW-FC2A-D030L PAW-FC2A-D040L PAW-FC2A-D050L PAW-FC2A-D060L PAW-FC2A-D070L PAW-FC2A-D080L
2-pipe - Right connection PAW-FC2A-D010R PAW-FC2A-D020R PAW-FC2A-D030R PAW-FC2A-D040R PAW-FC2A-D050R PAW-FC2A-D060R PAW-FC2A-D070R PAW-FC2A-D080R
Total cooling capacity - 2-pipe (Lo) (1) kW 0,7 0,7 1,0 1,2 1,7 2,7 3,4 4,6
Total cooling capacity - 2-pipe (Med) (1) kW 1,0 1,2 2,0 2,4 3,2 4,6 6,1 6,1
Total cooling capacity - 2-pipe (Hi) (1) kW 1,5 1,7 2,5 3,2 4,6 5,8 7,3 8,1
Sensible cooling capacity - 2-pipe (Lo) (1) kW 0,5 0,6 0,8 0,9 1,2 1,9 2,4 3,4
Sensible cooling capacity - 2-pipe (Med) (1) kW 0,8 0,9 1,5 1,8 2,2 3,3 4,3 4,6
Sensible cooling capacity - 2-pipe (Hi) (1) kW 1,1 1,3 1,9 2,3 3,3 4,5 5,1 6,3
Water flow - 2-pipe (Cooling) (Lo) l/h 124 127 172 206 296 466 587 798
Water flow - 2-pipe (Cooling) (Med) l/h 172 213 341 413 544 784 1.058 1.048
Water flow - 2-pipe (Cooling) (Hi) l/h 250 289 430 547 798 1.003 1.252 1.400
Water pressure drop - 2-pipe (Cooling) (Lo) kPa 10,7 1,9 6,3 5,4 7,5 13,9 4,8 11,9
Water pressure drop - 2-pipe (Cooling) (Med) kPa 19,5 3,9 19,3 17,1 22,8 37,4 15,4 19,3
Water pressure drop - 2-pipe (Cooling) (Hi) kPa 39,2 6,3 28,8 28,0 46,9 60,2 21,5 32,5
Heating capacity - 2-pipe (Lo) (2) kW 0,9 0,9 1,3 1,4 2,1 3,1 4,3 5,9
Heating capacity - 2-pipe (Med) (2) kW 1,4 1,5 2,4 2,9 4,1 5,3 7,9 8,1
Heating capacity - 2-pipe (Hi) (2) kW 2,0 2,2 3,1 4,0 5,7 7,1 9,3 11,6
4-pipe - Left connection PAW-FC4A-D010L PAW-FC4A-D020L PAW-FC4A-D030L PAW-FC4A-D040L PAW-FC4A-D050L PAW-FC4A-D060L PAW-FC4A-D070L PAW-FC4A-D080L
4-pipe - Right connection PAW-FC4A-D010R PAW-FC4A-D020R PAW-FC4A-D030R PAW-FC4A-D040R PAW-FC4A-D050R PAW-FC4A-D060R PAW-FC4A-D070R PAW-FC4A-D080R
Total cooling capacity - 4-pipe (Lo) (1) kW 0,7 0,6 1,0 1,1 1,7 2,6 3,3 4,5
Total cooling capacity - 4-pipe (Med) (1) kW 0,9 1,1 1,9 2,3 3,0 4,4 5,9 5,9
Total cooling capacity - 4-pipe (Hi) (1) kW 1,3 1,6 2,4 3,0 4,3 5,6 6,9 8,0
Sensible cooling capacity - 4-pipe (Lo) (1) kW 0,5 0,5 0,8 0,8 1,2 1,8 2,3 3,3
Sensible cooling capacity - 4-pipe (Med) (1) kW 0,7 0,8 1,5 1,7 2,2 3,2 4,2 4,4
Sensible cooling capacity - 4-pipe (Hi) (1) kW 1,0 1,2 1,8 2,2 3,1 4,3 4,9 6,2
Water flow - 4-pipe (Cooling) (Lo) l/h 114 109 165 194 284 449 575 775
Water flow - 4-pipe (Cooling) (Med) l/h 159 192 327 388 522 756 1.019 1.020
Water flow - 4-pipe (Cooling) (Hi) l/h 225 268 414 517 748 967 1.193 1.380
Water pressure drop - 4-pipe (Cooling) (Lo) kPa 8,3 1,5 3,0 6,4 4,2 10,2 5,9 19,3
Water pressure drop - 4-pipe (Cooling) (Med) kPa 15,2 3,4 9,5 22,3 12,8 27,7 17,9 31,1
Water pressure drop - 4-pipe (Cooling) (Hi) kPa 29,0 5,6 14,4 36,8 25,1 44,5 24,4 53,6
Heating capacity - 4-pipe (Lo) (2) kW 0,5 0,6 1,0 0,9 1,5 1,9 2,7 3,9
Heating capacity - 4-pipe (Med) (2) kW 0,7 0,9 1,4 1,6 2,3 2,9 3,6 5,6
Heating capacity - 4-pipe (Hi) (2) kW 1,0 1,1 1,6 2,1 3,0 3,7 4,3 7,1
Water flow (Heating) (Lo) l/h 79 100 164 160 251 325 456 673
Water flow (Heating) (Med) l/h 127 146 232 273 401 505 626 963
Water flow (Heating) (Hi) l/h 178 190 274 354 508 633 736 1.226
Water pressure drop (Heating) (Lo) kPa 1,9 1,5 5,1 9,2 10,7 20,3 67,2 33,1
Water pressure drop (Heating) (Med) kPa 3,5 3,2 9,0 26,5 24,6 43,9 117,9 63,7
Water pressure drop (Heating) (Hi) kPa 5,6 5,3 11,9 42,7 29,5 52,9 137,8 75
Sound levels . . . . . . . .
Sound power (Lo) dB(A) 33 31 30 30 34 38 43 50
Sound power (Med) dB(A) 40 43 45 44 46 51 56 55
Sound power (Hi) dB(A) 49 50 52 51 56 58 61 64
Sound pressure (Lo) (3) dB(A) 24 22 21 21 25 29 34 41
Sound pressure (Med) (3) dB(A) 31 34 36 35 37 42 47 46
Sound pressure (Hi) (3) dB(A) 40 41 43 42 47 49 52 55
Fan data . . . . . . . .
Number of fans 1 1 1 2 2 2 2 3
Air flow - 2-pipe (Lo) m³/h 111 105 138 173 253 350 480 660
Air flow - 2-pipe (Med) m³/h 190 179 274 357 486 640 893 936
Air flow - 2-pipe (Hi) m³/h 283 265 390 499 716 933 1.064 1.397
Air flow - 4-pipe (Lo) m³/h 95 89 132 162 242 334 470 634
Air flow - 4-pipe (Med) m³/h 168 161 263 335 466 614 859 905
Air flow - 4-pipe (Hi) m³/h 253 241 369 467 671 885 1.012 1.370
Maximum external pressure Pa 55 55 65 85 85 115 125 70
Filter G2 G2 G2 G2 G2 G2 G2 G2
Electrical data . . . . . . . .
Power supply (Voltage) V 230 230 230 230 230 230 230 230
Power supply (Phase) Single phase Single phase Single phase Single phase Single phase Single phase Single phase Single phase
Power supply (Frequency) Hz 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60
Power consumption - 2-pipe (Lo) W 13 10 16 15 28 37 53 90
Power consumption - 2-pipe (Med) W 24 18 37 37 55 75 100 112
Power consumption - 2-pipe (Hi) W 36 29 45 56 72 105 147 188
Power consumption - 4-pipe (Lo) W 13 10 16 15 28 37 53 90
Power consumption - 4-pipe (Med) W 24 18 37 37 54 74 99 112
Power consumption - 4-pipe (Hi) W 36 28 44 55 70 104 145 188
Fan coils water connections . . . . . . . .
Type of water connections Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded
Water connections - 2-pipe Inch 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4
Water connections - 4-pipe (Cooling) Inch 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4
Water connections - 4-pipe (Heating) Inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Dimensions and weight . . . . . . . .
Dimension (Height) mm 220 220 220 220 220 220 220 220
Dimension (Width) mm 570 570 730 938 1.122 1.307 1.121 1.316
Dimension (Depth) mm 430 430 430 430 430 430 530 530
Weight - 2-pipe kg 13 13 15 20 22 26 27 38
Weight - 4-pipe kg 14 14 16 22 24 28 29 40

1) According to Eurovent standard. Air: 27°C DB / 19°C WB. Water in/out: 7°C / 12°C.
2) Air: 20°C. Water in/out: 50°C / 45°C.
3) The sound pressure levels are based on (NR) characteristics of a room having volume of 100m³ with reverberation of 0,5 seconds.
Values indicated are for 0Pa external static pressure, for additional pressure characteristics, please refer the technical data manual.

Complementary products