Etherea with nanoe™ X matt white R32

Etherea with nanoe™ X technology

Built-in nanoe X Generator Mark 3

A smart solution to keep your home clean, comfortable and welcoming
The smart, new Etherea comes with nanoe™ X technology with the benefits of hydroxyl radicals. With advanced control options, class-leading performance, a stylish design and intelligent features, Etherea is designed to make your home comfortable, clean and the ideal place to be.

The air conditioning connects with the future

Specifications

See all
Etherea with nanoe™ X matt white R32 SINGLE PHASE
2.05 kW 2.50 kW 3.50 kW 4.20 kW 5.00 kW 7.10 kW
Kit KIT-Z20-ZKE KIT-Z25-ZKE KIT-Z35-ZKE KIT-Z42-ZKE KIT-Z50-ZKE KIT-Z71-ZKE
Cooling capacity (Nominal) kW 2,05 2,50 3,50 4,20 5,00 7,10
Cooling capacity (Min) kW 0,75 0,85 0,85 0,85 0,98 0,98
Cooling capacity (Max) kW 2,65 3,50 4,20 5,00 6,00 8,50
EER (Nominal) (1) W/W 4,66 4,90 4,27 3,39 3,68 3,24
EER (Min) (1) W/W 4,69 5,00 4,25 3,62 3,92 2,33
EER (Max) (1) W/W 4,02 3,89 3,62 3,18 3,16 2,83
SEER (2) 8,70 A+++ 9,50 A+++ 9,50 A+++ 7,10 A++ 8,50 A+++ 6,50 A++
Pdesign (cooling) kW 2,1 2,5 3,5 4,2 5,0 7,1
Input power cooling (Nominal) kW 0,44 0,51 0,82 1,24 1,36 2,19
Input power cooling (Min) kW 0,16 0,17 0,20 0,24 0,25 0,42
Input power cooling (Max) kW 0,66 0,90 1,16 1,57 1,90 3,00
Annual energy consumption cooling (3) kWh/a 84 92 129 207 206 382
Heating capacity (Nominal) kW 2,80 3,40 4,00 5,30 5,80 8,20
Heating capacity (Min) kW 0,75 0,80 0,80 0,80 0,98 0,98
Heating capacity (Max) kW 4,00 4,80 5,50 6,80 8,00 10,20
Heating capacity at -7°C kW 2,38 2,8 3,2 4,11 4,8 6,31
COP (Nominal) (1) W/W 4,67 4,86 4,55 3,73 4,14 3,73
COP (Min) (1) W/W 4,69 5,00 4,44 4,21 4,26 2,45
COP (Max) (1) W/W 4,26 4,07 3,77 3,66 3,35 3,31
SCOP (2) 4,80 A++ 5,20 A+++ 5,20 A+++ 4,30 A+ 4,80 A++ 4,20 A+
Pdesign at -10°C kW 2,4 2,6 2,9 3,6 4,2 5,5
Input power heating (Nominal) kW 0,60 0,70 0,88 1,42 1,40 2,20
Input power heating (Min) kW 0,16 0,16 0,18 0,19 0,23 0,40
Input power heating (Max) kW 0,94 1,18 1,46 1,86 2,39 3,08
Annual energy consumption heating (3) kWh/a 700 700 781 1.172 1.225 1.833
Indoor unit CS-Z20ZKEW CS-Z25ZKEW CS-Z35ZKEW CS-Z42ZKEW CS-Z50ZKEW CS-Z71ZKEW
Indoor power source V 230 230 230 230 230 230
Indoor recommended fuse A 16 16 16 16 16 20
Indoor connection indoor / outdoor mm² 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5 4 x 2,5 4 x 2,5
Indoor air flow (Cool) m³/min 10,4 12,4 12,7 14,5 17,4 19,0
Indoor air flow (Heat) m³/min 11,9 13,0 14,4 15,4 19,1 19,9
Moisture removal volume L/h 1,3 1,5 2 2,4 2,8 4,1
Indoor sound pressure (Cool - Hi) (4) dB(A) 35 39 42 43 44 47
Indoor sound pressure (Cool - Hi) (4) dB(A) 35 39 42 43 44 47
Indoor sound pressure (Cool - Lo) (4) dB(A) 24 25 28 31 37 38
Indoor sound pressure (Cool - Q-Lo) (4) dB(A) 19 19 19 25 30 30
Indoor sound pressure (Heat - Hi) (4) dB(A) 36 39 43 43 44 47
Indoor sound pressure (Heat - Lo) (4) dB(A) 25 27 33 35 37 38
Indoor sound pressure (Heat - Q-Lo) (4) dB(A) 19 19 19 29 30 30
Indoor dimension (Height) mm 295 295 295 295 295 295
Indoor dimension (Width) mm 870 870 870 870 1.040 1.040
Indoor dimension (Depth) mm 229 229 229 229 244 244
Indoor net weight kg 10 10 11 10 12 13
nanoe X Generator Mark 3 Mark 3 Mark 3 Mark 3 Mark 3 Mark 3
Outdoor unit CU-Z20ZKE CU-Z25ZKE CU-Z35ZKE CU-Z42ZKE CU-Z50ZKE CU-Z71ZKE
Outdoor air flow (Cool) m³/min 26,5 28,7 29,8 29,8 39,8 44,7
Outdoor air flow (Heat) m³/min 25,7 26,5 29,8 30,9 36,9 45,8
Outdoor sound pressure (Cool - Hi) (4) dB(A) 45 46 48 49 47 52
Outdoor sound pressure (Cool - Hi) (4) dB(A) 45 46 48 49 47 52
Outdoor sound pressure (Heat - Hi) (4) dB(A) 46 47 50 51 47 54
Outdoor dimension (Height) (5) mm 542 542 542 542 695 695
Outdoor dimension (Width) (5) mm 780 780 780 780 875 875
Outdoor dimension (Depth) (5) mm 289 289 289 289 320 320
Outdoor net weight kg 27 27 31 31 40 45
Piping diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Piping diameter (Gas) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 1/2 (12,70) 1/2 (12,70) 5/8 (15,88)
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 30 3 ~ 30
Elevation difference (in/out) (6) m 15 15 15 15 15 20
Pre-charged pipe length m 7,5 7,5 7,5 7,5 7,5 10
Additional gas amount g/m 10 10 10 10 15 25
Refrigerant (R32) / CO2 Eq. kg / T 0,70 / 0,47 0,70 / 0,47 0,81 / 0,55 0,83 / 0,56 1,13 / 0,76 1,35 / 0,91
Operating range (Cool - Min) °C -10 -10 -10 -10 -10 -10
Operating range (Cool - Min) °C -10 -10 -10 -10 -10 -10
Operating range (Cool - Max) °C +43 +43 +43 +43 +43 +43
Operating range (Heat - Min) °C -20 -20 -20 -20 -20 -20
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position of 1m in front of the main body and 0,8m below the unit. For outdoor unit 1m in front and 1m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70mm for piping port.

Complementary products