Energy recovery ventilation with DX coil - HRPT Series

Energy recovery ventilation with DX coil - HRPT Series for VRF

The HPRT Series is specifically designed for commercial applications or collective residential buildings, offering highly efficient heat recovery of up to 85,2%.
It’s an ideal solution to achieve the highest energy certification for buildings in the tertiary, industrial and collective residential sectors including centralized condominium systems.

Specifications

See all
Energy recovery ventilation with DX coil - HRPT Series SINGLE PHASE THREE PHASE
500 m³/h 800 m³/h 1.500 m³/h 1.700 m³/h 2.450 m³/h
Indoor unit with high-efficiency heat exchanger PAW-HRPT40HX PAW-HRPT80HX PAW-HRPT120HX PAW-HRPT160HX PAW-HRPT200HX
Indoor unit with sensible heat exchanger PAW-HRPT40 PAW-HRPT80 PAW-HRPT120 PAW-HRPT160 PAW-HRPT200
Heat recovery temperature efficiency cooling (1) % 63,4 (HX) / 84,6 60,0 (HX) / 84,3 61,4 (HX) / 84,8 62,2 (HX) / 84,7 59,4 (HX) / 83,8
Heat recovery temperature efficiency heating (1) % 76,7 (HX) / 84,9 73,5 (HX) / 84,7 75,0 (HX) (HX) / 85,2 76,0 (HX) / 85,1 73,2 (HX) / 84,2
Heat recovery enthalpy efficiency cooling (1) % 52,3 (HX) 47,8 (HX) 49,5 50,0 (HX) 46,8 (HX)
Heat recovery enthalpy efficiency heating (1) % 53,2 (HX) 49,2 (HX) 50,7 (HX) 51,2 (HX) 48,3 (HX)
Common data . . . . .
Power supply (Voltage) V 230 230 230 230 380
Power supply (Phase) Single phase Single phase Single phase Single phase Three phase
Power supply (Frequency) Hz 50 50 50 50 50
DX coil total / sensible capacity cooling (2) kW 3,0 / 2,4 6,0 / 4,1 8,0 / 5,5 10,0 / 7,1 12,5 / 8,6
DX coil total / sensible capacity heating (2) kW 3,2 6,2 8,3 11,0 12,8
Maximum input current A 1,5 2,2 4,1 4,4 3,3
Sound pressure dB(A) 41 (@1m) / 35 (@3m) 51 (@1m) / 43 (@3m) 42 (@1m) / 36 (@3m) 49 (@1m) / 41 (@3m) 57 (@1m) / 49 (@3m)
Air flow (Nominal) m³/h 400 800 1.200 1.600 2.000
External static pressure (High) Pa 150 150 150 150 150
Dimension (Height) mm 286 425 425 425 425
Dimension (Width) mm 1.003 1.226 1.628 2.030 2.030
Dimension (Depth) mm 1475 1.878 1.878 1.720 1.878
Net weight kg 70 (HX) / 66 114 (HX) / 110 150 (HX) / 145 184 (HX) / 180 194 (HX) / 190
Piping diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Piping diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)

1) Data refers to the following conditions (UNI EN 13141-7): nominal air flow, heating external air 5°C with 72% r. / expelled air 25°C with 28% r. - cooling 35°C with 40% / expelled air 27°C with 48%.
2) Data refers to the following conditions: nominal air flow, cooling inlet coil summer 27°C with 48% / heating inlet coil winter 20°C with 50% r.