Models
Panasonic energy recovery ventilators help you with your comfort and energy-saving plan
Suppresses indoor temperature changes while providing fresh air. Recovers up to 77% of the heat in the outgoing air, for an ecological and energy efficient building.
- High energy saving, up to 20%
- Counter Cross Flow technology for better efficiency
- Long life element core
- Easy installation and 20% less thickness
- Easy connection to air conditioning units
- Silent units
Specifications
ERV ZDY Series | SINGLE PHASE | ||||||
---|---|---|---|---|---|---|---|
Power supply (Voltage) | V | 220 - 240 | 220 - 240 | 220 - 240 | 220 - 240 | 220 - 240 | |
Power supply (Frequency) | Hz | 50 | 50 | 50 | 50 | 50 | |
Input power (Extra high - 220V) | W | 112,0 | 182,0 | 263,0 | 387,0 | 437,0 | |
Input power (High - 220V) | W | 108,0 | 178,0 | 204,0 | 360,0 | 416,0 | |
Input power (Low - 220V) | W | 87,0 | 175,0 | 165,0 | 293,0 | 301,0 | |
Input power (Extra high - 240V) | W | 128,0 | 190,0 | 289,0 | 418,0 | 464,0 | |
Input power (High - 240V) | W | 123,0 | 185,0 | 225,0 | 378,0 | 432,0 | |
Input power (Low - 240V) | W | 96,0 | 168,0 | 185,0 | 295,0 | 311,0 | |
Air flow (Extra high) | m³/h | 250 | 350 | 500 | 800 | 1.000 | |
Air flow (High) | m³/h | 250 | 350 | 500 | 800 | 1.000 | |
Air flow (Low) | m³/h | 190 | 240 | 440 | 630 | 700 | |
External static pressure (Extra high) | Pa | 105 | 140 | 120 | 140 | 105 | |
External static pressure (High) | Pa | 95 | 60 | 60 | 110 | 80 | |
External static pressure (Low) | Pa | 45 | 45 | 35 | 55 | 75 | |
Sound power - heat exchange (Extra high - 220V) | dB(A) | 30,0 | 32,5 | 36,5 | 37,0 | 37,5 | |
Sound power - heat exchange (High - 220V) | dB(A) | 29,5 | 30,5 | 34,5 | 36,5 | 37,0 | |
Sound power - heat exchange (Low - 220V) | dB(A) | 23,5 | 22,5 | 31,0 | 33,5 | 33,5 | |
Sound power - heat exchange (Extra high - 240V) | dB(A) | 31,5 | 33,0 | 37,5 | 37,5 | 38,5 | |
Sound power - heat exchange (High - 240V) | dB(A) | 30,5 | 31,0 | 35,5 | 37,0 | 37,5 | |
Sound power - heat exchange (Low - 240V) | dB(A) | 26,5 | 25,5 | 32,5 | 34,5 | 34,5 | |
Sound power - normal (Extra high - 220V) | dB(A) | 30,0 | 32,5 | 37,5 | 37,0 | 39,5 | |
Sound power - normal (High - 220V) | dB(A) | 29,5 | 30,5 | 37,0 | 36,5 | 39,0 | |
Sound power - normal (Low - 220V) | dB(A) | 23,5 | 22,5 | 31,0 | 33,5 | 35,5 | |
Sound power - normal (Extra high - 240V) | dB(A) | 31,5 | 33,0 | 38,5 | 37,5 | 40,5 | |
Sound power - normal (High - 240V) | dB(A) | 30,5 | 31,0 | 38,0 | 37,0 | 39,5 | |
Sound power - normal (Low - 240V) | dB(A) | 26,5 | 25,5 | 32,5 | 34,5 | 36,5 | |
Temperature exchange efficiency - heat exchange (Extra high) | % | 75 | 75 | 75 | 75 | 75 | |
Temperature exchange efficiency - heat exchange (High) | % | 75 | 75 | 75 | 75 | 75 | |
Temperature exchange efficiency - heat exchange (Low) | % | 77 | 78 | 76 | 76 | 79 | |
Dimension (Height) | mm | 270 | 317 | 317 | 388 | 388 | |
Dimension (Width) | mm | 882 | 1.050 | 1.090 | 1.322 | 1.322 | |
Dimension (Depth) | mm | 599 | 804 | 904 | 884 | 1.134 | |
Net weight | kg | 29 | 49 | 57 | 71 | 83 |
This noise of the product is the value which was measured at the acoustic room. Actually, in the established condition, that undergo influence by the echoing of the room and so that become bigger than the display numerical value. The input, the current and the exchange efficiency are values at the time of the mentioned air flow. The noise level shall be measured 1,5 m below the centre of the unit. The temperature exchange efficiency averages that of when cooling and when heating.