Specifications

See all
Bi-bloc K Series 3 phase · R32 THREE PHASE
9 kW 12 kW 16 kW
Kit 3kW electric heater KIT-WC09K3E8
Kit 9kW electric heater KIT-WC09K9E8 KIT-WC12K9E8 KIT-WC16K9E8
Heating capacity (A +7°C, W 35°C) kW 9,00 12,10 16,00
COP (A +7°C, W 35°C) 4,90 4,78 4,31
Heating capacity (A +7°C, W 55°C) kW 9,00 12,00 14,70
COP (A +7°C, W 55°C) 2,97 2,96 2,72
Heating capacity (A +2°C, W 35°C) kW 9,00 11,50 13,20
COP (A +2°C, W 35°C) 3,63 3,44 3,28
Heating capacity (A +2°C, W 55°C) kW 9,00 9,20 10,00
COP (A +2°C, W 55°C) 2,26 2,25 2,21
Heating capacity (A -7°C, W 35°C) kW 9,00 10,10 11,60
COP (A -7°C, W 35°C) 2,88 2,74 2,57
Heating capacity (A -7°C, W 55°C) kW 8,10 8,40 9,10
COP (A -7°C, W 55°C) 2,07 1,97 1,85
Cooling capacity (A 35°C, W 7°C) kW 8,80 10,70 13,40
EER (A 35°C, W 7°C) 3,11 2,68 2,64
Cooling capacity (A 35°C, W 18°C) kW 8,80 10,70 15,50
EER (A 35°C, W 18°C) 4,63 3,92 3,60
Heating average climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,6 / 3,57 4,58 / 3,33 4,46 / 3,40
Heating average climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 15 / 140) 180 / 130) 176 / 133)
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++
Heating cold climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 6,47 / 4,34 6,47 / 4,34 6,20 / 4,30
Heating cold climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 256 / 171) 256 / 171) 245 / 16)
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating warm climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,31 / 3,26 4,31 / 3,26 4,28 / 3,10
Heating warm climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 16 / 127) 16 / 127) 168 / 121)
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++ A++ / A+
Indoor unit 3kW electric heater WH-SDC09K3E8
Indoor unit 9kW electric heater WH-SDC09K9E8 WH-SDC12K9E8 WH-SDC16K9E8
Indoor sound pressure (Heat) dB(A) 33 33 33
Indoor sound pressure (Cool) dB(A) 33 33 33
Indoor dimension (Height) mm 892 892 892
Indoor dimension (Width) mm 500 500 500
Indoor dimension (Depth) mm 348 348 348
Indoor net weight kg 40 (3kW) / 41 (9kW) 41 41
Water pipe connector Inch R 1¼ R 1¼ R 1¼
A class pump (Number of speeds) Variable speed Variable speed Variable speed
A class pump (Input power) W 145 145 145
Heating water flow (∆T=5 K. 35°C) L/min 25,8 34,4 45,9
Outdoor unit WH-UDZ09KE8 WH-UDZ12KE8 WH-UDZ16KE8
Outdoor sound power (Heat) (2) dB(A) 65 65 65
Outdoor dimension (Height) mm 1.340 1.340 1.340
Outdoor dimension (Width) mm 900 900 900
Outdoor dimension (Depth) mm 320 320 320
Outdoor net weight kg 90 90 103
Refrigerant (R32) / CO2 Eq. kg / T 1,60 / 1,080 1,60 / 1,080 1,83 / 1,235
Piping diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Piping diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70)
Pipe length range m 3 ~ 30 3 ~ 30 3 ~ 30
Elevation difference (in/out) m 20 20 20
Pre-charged pipe length m 10 10 10
Additional gas amount g/m 30 30 30
Operation range - Outdoor ambient (Heat) °C -25 ~ +35 -25 ~ +35 -25 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43
Water outlet (Heat) (3) °C 20 ~ 60 20 ~ 60 20 ~ 60
Water outlet (Cool) (3) °C 5 ~ 20 5 ~ 20 5 ~ 20
Electrical information 3kW — 9kW 9kW 9kW
Electric backup heater kW 3,00 — 9,00 9,00 9,00
Recommended fuse A 20 / 15 / 16 — 20 / 20 20 / 20 20 / 20
Recommended minimum cable size, supply 1 (4) mm² 5x1,5 — 5x1,5 5x1,5 5x2,5
Recommended minimum cable size, supply 2 (4) mm² 3x1,5 — 5x1,5 5x1,5 5x1,5

1) Scale from A+++ to D.
2) Sound power level in accordance to EN12102 under conditions of the EN14825.
3) Operation range down to -25°C in heating with 3 ~ 40m pipe length range, operation range down to -15°C in heating with 3 ~ 50m pipe length range.
4) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
*** Available in Summer 2024. Tentative data.

Complementary products