Aquarea High Performance All in One Compact H Generation 1 Phase - R410A

Aquarea All in One Compact unit is the ultimate space-saving solution

Aquarea warms your home effectively and efficiently, even with extreme outdoor temperatures. Aquarea can also cool space in summer and bring hot water all year round.
Aquarea High Performance is the range for new installations and low consumption homes. Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
The Aquarea All in One belongs to the new generation of Panasonic heat pumps for heating, cooling and providing domestic hot water in the home. Improved square design with white goods finish.
Its 598 x 600mm footprint, standard size of other big appliances, reduces the space required for the installation.

Energy efficiency: A+++ in heating at 35°C and A in DHW / “A” water pump with variable speed / Stainless steel DHW tank with U-Vacua™ insulation panel / Built-in flow meter.
Flexibility: 598 x 600 footprint / Built-in magnetic water filter.
Comfort: Operation range down to -20°C.
Control: Additional functions with optional PCB (2 zone control, bivalent control, Smart Grid contact and more).
Connectivity: Optional Aquarea Smart and Service Cloud and integration into BMS projects.

The newest of Aquarea

Specifications

See all
Aquarea High Performance All in One Compact H Generation 1 Phase - R410A SINGLE PHASE (Power to indoor)
12.0 kW 16.0 kW
Kit KIT-ADC12HE5C KIT-ADC16HE5C
Heating capacity (A +7°C, W 35°C) kW 12,00 16,00
COP (A +7°C, W 35°C) 4,74 4,28
Heating capacity (A +7°C, W 55°C) kW
COP (A +7°C, W 55°C)
Heating capacity (A +2°C, W 35°C) kW 11,40 13,00
COP (A +2°C, W 35°C) 3,44 3,28
Heating capacity (A +2°C, W 55°C) kW
COP (A +2°C, W 55°C)
Heating capacity (A -7°C, W 35°C) kW
COP (A -7°C, W 35°C)
Heating capacity (A -7°C, W 55°C) kW
COP (A -7°C, W 55°C)
Cooling capacity (A 35°C, W 7°C) kW 10,00 12,20
EER (A 35°C, W 7°C) 2,81 2,56
Cooling capacity (A 35°C, W 18°C) kW
EER (A 35°C, W 18°C)
Heating average climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 190 / 134 190 / 130
Heating average climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,82 / 3,42 4,82 / 3,33
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 245 / 159 245 / 169
Heating warm climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 6,21 / 4,05 6,20 / 4,30
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 168 / 121 168 / 121
Heating cold climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,29 / 3,10 4,28 / 3,10
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+ A++ / A+
Indoor unit WH-ADC1216H6E5C WH-ADC1216H6E5C
Indoor sound pressure (Heat) dB(A) 33 33
Indoor sound pressure (Cool) dB(A) 33 33
Indoor dimension (Height) mm 1.640 1.640
Indoor dimension (Width) mm 598 598
Indoor dimension (Depth) mm 600 600
Indoor net weight kg 101 101
Water pipe connector Inch R 1  R 1 
A class pump (Number of speeds) Variable Speed Variable Speed
A class pump (Input power Min) W
A class pump (Input power Max) W
Heating water flow (∆T=5 K. 35°C) L/min 34,40 45,90
Capacity of integrated electric heater kW 6,00 6,00
Indoor recommended fuse A — / — — / —
Recommended minimum cable size, supply 1 mm²
Recommended minimum cable size, supply 2 mm²
Water volume L 185 185
Maximum DHW temperature °C 65 65
Material inside tank Stainless steel Stainless steel
Tapping profile according EN16147
DHW tank ERP average climate efficiency rating (2) A+ to F
DHW tank ERP warm climate efficiency rating (2) A+ to F
DHW tank ERP cold climate efficiency rating (2) A+ to F
DHW tank ERP average climate η ηwh % 92 88
DHW tank ERP average climate COPdHW COPdHW 2,30 2,20
DHW tank ERP warm climate η ηwh % 107 104
DHW tank ERP warm climate COPdHW COPdHW 2,67 2,59
DHW tank ERP cold climate η ηwh % 72 70
DHW tank ERP cold climate COPdHW COPdHW 1,81 1,74
Outdoor unit WH-UD12HE5 WH-UD16HE5
Outdoor sound power (Heat) (3) dB(A) 65 65
Outdoor dimension (Height) mm 1.340 1.340
Outdoor dimension (Width) mm 900 900
Outdoor dimension (Depth) mm 320 320
Outdoor net weight kg 101 101
Refrigerant (R410A) / CO2 Eq. kg / T 2,55 / 5,324 2,55 / 5,324
Piping diameter (Liquid) Inch (mm) 3/8 (9,52) 3/8 (9,52)
Piping diameter (Gas) Inch (mm) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 50 3 ~ 50
Elevation difference (in/out) m 30 30
Pre-charged pipe length m 10 10
Additional gas amount g/m 50 50
Operation range - Outdoor ambient (Heat) °C -20 ~ +35 -20 ~ +35
Operation range - Outdoor ambient (Cool) °C +16 ~ +43 +16 ~ +43
Water outlet (Heat) °C 20 ~ 55 20 ~ 55
Water outlet (Cool) °C 5 ~ 20 5 ~ 20

1) Scale from A+++ to D.
2) Scale from A+ to F.
3) Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7°C.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.