Aquarea EcoFleX 1 phase · R32

Aquarea EcoFleX

Aquarea EcoFleX is a groundbreaking heat pump that connects an air ducted unit with nanoe™ X technology providing heat recovery hot water, space heating, space cooling and cleaner air.


Multi solution

Trendy air to water + DX value added solution, featuring bi-heating and heat recovery function.

Bi-heating: Simultaneous air heating and DHW or heating.
Heat recovery: Re-use wasted heat from the outdoor unit for DHW production.
Non-stop heating: Air heating runs continuously even in defrost operation.

Energy efficiency: Heat recovery function, to re-use wasted heat of outdoor unit for DHW production.
Flexibility: Small foot print outdoor unit, tank unit with a standard size of appliances.
Comfort: Non-stop heating operation / nanoe™ X technology to improve protection 24/7 (nanoe X Generator Mark 2).
Connectivity: Wi-Fi adapters included for instant connectivity via Aquarea Smart Cloud or Panasonic Comfort Cloud App.

Latest news

One outdoor unit for synchronous A2A and A2W supply

Owning an Aquarea?

Specifications

See all
Aquarea EcoFleX 1 phase · R32 SINGLE PHASE
8.00 kW
Kit WH-ADF0309J3E5CM + S-71WF3E + CU-2WZ71YBE5
Indoor unit - Air to water WH-ADF0309J3E5CM
Heating capacity (A +7°C, W 35°C) kW 8,00
COP (A +7°C, W 35°C) 4,21
Heating capacity (A +7°C, W 55°C) kW 8,00
COP (A +7°C, W 55°C) 2,81
Heating capacity (A +2°C, W 35°C) kW 6,70
COP (A +2°C, W 35°C) 3,25
Heating capacity (A +2°C, W 55°C) kW 6,00
COP (A +2°C, W 55°C) 2,08
Heating capacity (A -7°C, W 35°C) kW 5,60
COP (A -7°C, W 35°C) 2,84
Heating capacity (A -7°C, W 55°C) kW 5,30
COP (A -7°C, W 55°C) 1,91
Cooling capacity (A 35°C, W 7°C) kW
EER (A 35°C, W 7°C)
Cooling capacity (A 35°C, W 18°C) kW
EER (A 35°C, W 18°C)
Heating average climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 157 / 125
Heating average climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,00 / 3,20
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++
Heating warm climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 224 / 145
Heating warm climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 5,69 / 3,69
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating cold climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 141 / 109
Heating cold climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 3,61 / 2,80
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+ / A+
Indoor A2W sound pressure (Heat) dB(A) 28
Indoor A2W sound pressure (Cool) dB(A)
Indoor A2W dimension (Height) mm 1.880
Indoor A2W dimension (Width) mm 598
Indoor A2W dimension (Depth) mm 600
Indoor A2W net weight kg 108
Capacity of integrated electric heater kW 3,00
Water volume L 185
Maximum DHW temperature °C 65
Heating water flow (∆T=5 K. 35°C) L/min 22,90
Tapping profile according EN16147 L
DHW tank ERP average climate efficiency rating (2) A+ to F A
DHW tank ERP warm climate efficiency rating (2) A+ to F A+
DHW tank ERP cold climate efficiency rating (2) A+ to F A
DHW tank ERP average climate η ηwh % 104
DHW tank ERP average climate COPdHW COPdHW 2,60
DHW tank ERP warm climate η ηwh % 134
DHW tank ERP warm climate COPdHW COPdHW 3,35
DHW tank ERP cold climate η ηwh % 92
DHW tank ERP cold climate COPdHW COPdHW 2,30
Heat recovery capacity (DHW 55°C) kW 7,10 + 9,00
Heat recovery input power (DHW 55°C) kW 3,15
Heat recovery COP (DHW 55°C) 5,11
Water outlet (Heat) °C 20 ~ 55
Indoor unit - Air to air S-71WF3E
Cooling capacity (Nominal) kW 7,10
EER (3) W/W 3,40
SEER (4) 5,60 A+
Pdesign (cooling) kW 7,10
Heating capacity (Nominal) kW 7,10 
COP (3) W/W 3,90
SCOP (4) 3,90 A
Pdesign at -10°C kW 4,80
External static pressure (Nominal) (5) Pa 30
External static pressure (Min) (5) Pa 10
External static pressure (Max) (5) Pa 150
Air flow m³/min 22,7
Indoor sound pressure (Cool - Hi) (6) dB(A) 34
Indoor sound pressure (Heat - Hi) (6) dB(A) 34
Indoor sound power (Cool - Hi) (7) dB(A) 57
Indoor sound power (Heat - Hi) (7) dB(A) 57
Indoor dimension (Height) mm 250
Indoor dimension (Width) mm 1.000
Indoor dimension (Depth) mm 730
Indoor net weight kg 30
nanoe X Generator Mark 2
Outdoor unit CU-2WZ71YBE5
Outdoor sound pressure (Cool - air to air) dB(A) 49
Outdoor sound pressure (Heat - air to air) dB(A) 49
Outdoor sound power (Cool - air to air) (7) dB(A) 68
Outdoor sound power (Heat - air to air) (7) dB(A) 67
Outdoor sound pressure (Heat - air to water) dB(A) 51
Outdoor sound power (Heat - air to water) (8) dB(A) 61
Outdoor dimension (Height) mm 999
Outdoor dimension (Width) mm 940
Outdoor dimension (Depth) mm 340
Outdoor net weight kg 82
Refrigerant (R32) / CO2 Eq. kg / T 2,40 / 1,62
Piping diameter (Liquid) Inch (mm) 1/4 (6,35)
Piping diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 35
Elevation difference (in/out) m 30
Pre-charged pipe length m 30
Additional gas amount g/m 20
Operation range - Outdoor ambient (Heat - air to air) °C -15 ~ +24
Operation range - Outdoor ambient (Cool - air to air) °C -10 ~ +46
Operation range - Outdoor ambient (Heat - air to water) °C -15 ~ +35
Operation range - Outdoor ambient (Heat recovery - floor) °C +10 ~ +35
Operation range - Outdoor ambient (Heat recovery - DHW) °C +10 ~ +46

1) Scale from A+++ to D.
2) Scale from A+ to F.
3) EER and COP calculation is based in accordance to EN14511.
4) SEER and SCOP is calculated based on values of EU/626/2011.
5) Medium external static pressure setting from factory.
6) The sound pressure of the units shows the value measured of the position 1,5m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
7) Sound power is measured in accordance with EN14511 and EN12102-1:2017 at +7°C.
8) Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7°C.