All in One K Series 3 phase with Electrical Anode · R32

Aquarea High Performance All in One K Series Three phase with Electrical Anode

A revolution in design, efficiency, connectivity and sustainability.
Aquarea K Series is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance. This model is ideal for new installations and well-insulated homes.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit. The All in One model maintains its compactness with its encroachment of only 598 x 600mm, comparable to a household appliance.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.

Owning an Aquarea?

Specifications

See all
All in One K Series 3 phase with Electrical Anode · R32 THREE PHASE
9 kW 12 kW 16 kW
Kit KIT-ADC09K9E8AN KIT-ADC12K9E8AN KIT-ADC16K9E8AN
Heating capacity (A +7°C, W 35°C) kW 9,00 12,10 16,00
COP (A +7°C, W 35°C) 4,90 4,78 4,31
Heating capacity (A +7°C, W 55°C) kW 9,00 12,00 14,70
COP (A +7°C, W 55°C) 2,97 2,96 2,72
Heating capacity (A +2°C, W 35°C) kW 9,00 11,50 13,20
COP (A +2°C, W 35°C) 3,63 3,44 3,28
Heating capacity (A +2°C, W 55°C) kW 9,00 9,20 10,00
COP (A +2°C, W 55°C) 2,26 2,25 2,21
Heating capacity (A -7°C, W 35°C) kW 9,00 10,10 11,60
COP (A -7°C, W 35°C) 2,88 2,74 2,57
Heating capacity (A -7°C, W 55°C) kW 8,10 8,40 9,10
COP (A -7°C, W 55°C) 2,07 1,97 1,85
Cooling capacity (A 35°C, W 7°C) kW 8,80 10,70 13,40
EER (A 35°C, W 7°C) 3,11 2,68 2,64
Cooling capacity (A 35°C, W 18°C) kW 8,80 10,70 15,50
EER (A 35°C, W 18°C) 4,63 3,92 3,60
Heating average climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,96 / 3,57 4,58 / 3,33 4,46 / 3,40
Heating average climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 195 / 140 180 / 130 176 / 133
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 6,47 / 4,34 6,47 / 4,34 6,20 / 4,30
Heating warm climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 256 / 171 256 / 171 245 / 169
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,31 / 3,26 4,31 / 3,26 4,28 / 3,10
Heating cold climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 169 / 127 169 / 127 168 / 121
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++ A++ / A+
Indoor unit WH-ADC0912K9E8AN WH-ADC0912K9E8AN WH-ADC16K9E8AN
Indoor sound pressure (Heat) dB(A) 33 33 33
Indoor sound pressure (Cool) dB(A) 33 33 33
Indoor dimension (Height) mm 1.642 1.642 1.642
Indoor dimension (Width) mm 599 599 599
Indoor dimension (Depth) mm 602 602 602
Indoor net weight kg 102 102 103
Water pipe connector Inch R 1¼ R 1¼ R 1¼
A class pump (Number of speeds) Variable speed Variable speed Variable speed
A class pump (Input power) W 145 145 145
Heating water flow (∆T=5 K. 35°C) L/min 25,8 34,4 45,9
Water volume L 185 185 185
Maximum DHW temperature °C 65 65 65
Material inside tank Stainless steel Stainless steel Stainless steel
Tapping profile according EN16147 L L L
DHW tank ERP average climate efficiency rating (2) A+ to F A A A
DHW tank ERP warm climate efficiency rating (2) A+ to F A+ A+ A+
DHW tank ERP cold climate efficiency rating (2) A+ to F A A A
DHW tank ERP average climate η ηwh % 100 100 96
DHW tank ERP average climate COPdHW COPdHW 2,50 2,50 2,40
DHW tank ERP warm climate η ηwh % 116 116 115
DHW tank ERP warm climate COPdHW COPdHW 2,90 2,90 2,88
DHW tank ERP cold climate η ηwh % 80 80 76
DHW tank ERP cold climate COPdHW COPdHW 2,00 2,00 1,90
Outdoor unit WH-UDZ09KE8 WH-UDZ12KE8 WH-UDZ16KE8
Outdoor sound power (Heat) (3) dB(A) 65 65 65
Outdoor dimension (Height) mm 1.340 1.340 1.340
Outdoor dimension (Width) mm 900 900 900
Outdoor dimension (Depth) mm 320 320 320
Outdoor net weight kg 90 90 103
Refrigerant (R32) / CO2 Eq. kg / T 1,60 / 1,080 1,60 / 1,080 1,83 / 1,235
Piping diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Piping diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70)
Pipe length range m 3 ~ 30 3 ~ 30 3 ~ 30
Elevation difference (in/out) m 20 20 20
Pre-charged pipe length m 10 10 10
Additional gas amount g/m 30 30 30
Operation range - Outdoor ambient (Heat) °C -25 ~ +35 -25 ~ +35 -25 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43
Water outlet (Heat) (4) °C 20 ~ 60 20 ~ 60 20 ~ 60
Water outlet (Cool) (4) °C 5 ~ 20 5 ~ 20 5 ~ 20
Electrical information WH-ADC0912K9E8 WH-ADC0912K9E8 WH-ADC16K9E8
Electric backup heater kW 9,00 9,00 9,00
Recommended fuse A 20 / 20 20 / 20 20 / 20
Recommended minimum cable size, supply 2 (5) mm² 5x1,5 5x1,5 5x2,5
Recommended minimum cable size, supply 1 (5) mm² 5x1,5 5x1,5 5x1,5

1) Scale from A+++ to D.
2) Scale from A+ to F.
3) Sound power level in accordance to EN12102 under conditions of the EN14825.
4) Between outdoor ambient -10°C and -15°C, the water outlet temperature gradually decreases from 60°C to 55°C.
5) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
*** Available in Summer 2024. Tentative data.

Complementary products