Models
Simultaneous heating and cooling operation with heat recovery type
The 3-Pipe ECOi EX MF3 Series is one of the most advanced VRF systems.
Not only high-efficient performance for simultaneous heating and cooling, but also sophisticated installation and maintenance available.
- Upgraded COP 5,23 (average cooling and heating value for 18HP outdoor unit)
- Simultaneous cooling and heating operation with up to 39 indoor units
- Slim heat recovery boxes with just 200mm height fit with the ceiling space limited in hotel applications
- Rotation operation function and back-up operation function provided
- EER, COP: Eurovent certified
- Standardisation of outdoor unit to one compact casing size
- The constant-speed compressor adopts a high-performance internal high-pressure scroll
- Up to 52 indoor units connectable
- High external static pressure 80Pa with a newly designed fan, fan guard, motor, and casing
- Bluefin condenser outdoor unit
Particularly suitable for retail, hotels and office applications



Panasonic: delivering TOP energy efficiencies for many years
The complete VRF solution for efficiency, quality, and comfort.
Electricity or Gas or Hybrid? Advanced VRF technologies offering optimal choice and flexibility for the customers.
Panasonic ECOi is Eurovent certified
The Eurovent certification verifies the performance ratings of heating and cooling systems following European standards. Those data provides products efficiency with full transparency for the benefit of customers and professionals.
Panasonic: delivering TOP energy efficiencies for many years
The complete VRF solution for efficiency, quality, and comfort.
Electricity or Gas or Hybrid? Advanced VRF technologies offering optimal choice and flexibility for the customers.
Panasonic ECOi is Eurovent certified
The Eurovent certification verifies the performance ratings of heating and cooling systems following European standards. Those data provides products efficiency with full transparency for the benefit of customers and professionals.
Specifications
3-Pipe ECOi EX MF3 series combination from 18 to 48HP | THREE PHASE | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18 kW | 20 kW | 22 kW | 24 kW | 26 kW | 28 kW | 30 kW | 32 kW | 34 kW | 36 kW | 38 kW | 40 kW | 42 kW | 44 kW | 46 kW | 48 kW | |||
HP | 18HP | 20HP | 22HP | 24HP | 26HP | 28HP | 30HP | 32HP | 34HP | 36HP | 38HP | 40HP | 42HP | 44HP | 46HP | 48HP | ||
Outdoor unit | U-8MF3E8 + U-10MF3E8 | U-8MF3E8 + U-12MF3E8 | U-10MF3E8 + U-12MF3E8 | U-12MF3E8 + U-12MF3E8 | U-10MF3E8 + U-16MF3E8 | U-12MF3E8 + U-16MF3E8 | U-14MF3E8 + U-16MF3E8 | U-16MF3E8 + U-16MF3E8 | U-8MF3E8 + U-10MF3E8 + U-16MF3E8 | U-8MF3E8 + U-12MF3E8 + U-16MF3E8 | U-10MF3E8 + U-12MF3E8 + U-16MF3E8 | U-8MF3E8 + U-16MF3E8 + U-16MF3E8 | U-10MF3E8 + U-16MF3E8 + U-16MF3E8 | U-12MF3E8 + U-16MF3E8 + U-16MF3E8 | U-14MF3E8 + U-16MF3E8 + U-16MF3E8 | U-16MF3E8 + U-16MF3E8 + U-16MF3E8 | ||
Power supply (Voltage) | V | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | |
Power supply (Phase) | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | Three phase | ||
Power supply (Frequency) | Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |
Cooling capacity (Nominal) | kW | 50,0 | 56,0 | 61,5 | 68,0 | 73,0 | 78,5 | 85,0 | 90,0 | 96,0 | 101,0 | 107,0 | 113,0 | 118,0 | 124,0 | 130,0 | 135,0 | |
EER (1) | W/W | 4,90 | 4,31 | 4,24 | 3,89 | 3,88 | 3,65 | 3,59 | 3,49 | 4,10 | 3,90 | 3,88 | 3,72 | 3,72 | 3,58 | 3,55 | 3,49 | |
Current cooling (1p 220V / 3p 380) | A | 16,8 | 21,0 | 23,7 | 28,3 | 31,0 | 35,1 | 39,6 | 42,6 | 38,6 | 42,3 | 45,6 | 50,2 | 52,4 | 56,5 | 61,1 | 63,9 | |
Current cooling (1p 230V / 3p 400) | A | 16,0 | 20,0 | 22,5 | 26,9 | 29,5 | 33,4 | 37,6 | 40,5 | 36,7 | 40,2 | 43,3 | 47,7 | 49,7 | 53,7 | 58,1 | 60,7 | |
Current cooling (1p 240V / 3p 415) | A | 15,4 | 19,2 | 21,7 | 25,9 | 28,4 | 32,2 | 36,2 | 39,0 | 35,4 | 38,7 | 41,7 | 46,0 | 47,9 | 51,8 | 56,0 | 58,5 | |
Input power cooling | kW | 10,20 | 13,00 | 14,50 | 17,50 | 18,80 | 21,50 | 23,70 | 25,8 | 23,40 | 25,90 | 27,60 | 30,40 | 31,70 | 34,60 | 36,60 | 38,70 | |
Heating capacity | kW | 56,0 | 63,0 | 69,0 | 76,5 | 81,5 | 87,5 | 95,0 | 100,0 | 108,0 | 113,0 | 119,0 | 127,0 | 132,0 | 138,0 | 145,0 | 150,0 | |
COP (1) | W/W | 5,23 | 4,77 | 4,79 | 4,47 | 4,50 | 4,31 | 4,19 | 4,17 | 4,64 | 4,48 | 4,51 | 4,31 | 4,36 | 4,25 | 4,18 | 4,17 | |
Current heating (1p 220V / 3p 380) | A | 17,7 | 21,3 | 23,5 | 27,6 | 30,2 | 33,5 | 37,9 | 40,1 | 38,9 | 41,6 | 43,6 | 49,3 | 50,6 | 53,7 | 57,9 | 60,1 | |
Current heating (1p 230V / 3p 400) | A | 16,8 | 20,3 | 22,3 | 26,3 | 28,7 | 31,8 | 36,0 | 38,1 | 37,0 | 39,5 | 41,4 | 46,8 | 48,1 | 51,0 | 55,0 | 57,1 | |
Current heating (1p 240V / 3p 415) | A | 16,2 | 19,5 | 21,5 | 25,3 | 27,7 | 30,7 | 34,7 | 36,7 | 35,6 | 38,1 | 39,9 | 45,1 | 46,3 | 49,1 | 53,0 | 55,0 | |
Input power heating | kW | 10,70 | 13,20 | 14,40 | 17,10 | 18,10 | 20,30 | 22,70 | 24,00 | 23,30 | 25,20 | 26,40 | 29,50 | 30,30 | 32,50 | 34,70 | 36,00 | |
Starting current | A | 2,00 | 2,00 | 2,00 | 2,00 | 3,00 | 3,00 | 4,00 | 4,00 | 4,00 | 4,00 | 4,00 | 5,00 | 5,00 | 5,00 | 6,00 | 6,00 | |
External static pressure (Max) | Pa | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |
Air flow | m³/min | 430 | 442 | 452 | 464 | 452 | 464 | 464 | 464 | 662 | 674 | 684 | 674 | 684 | 696 | 696 | 696 | |
Sound pressure (Normal mode) | dB(A) | 59,0 | 61,0 | 62,0 | 63,0 | 63,5 | 64,5 | 64,5 | 65,0 | 64,0 | 64,5 | 65,0 | 65,5 | 66,0 | 66,5 | 66,5 | 67,0 | |
Sound pressure (Silent mode 1) | dB(A) | 56,0 | 58,0 | 59,0 | 60,0 | 60,5 | 61,5 | 61,5 | 62,0 | 61,0 | 61,5 | 62,0 | 62,5 | 63,0 | 63,5 | 63,5 | 64,0 | |
Sound pressure (Silent mode 2) | dB(A) | 54,0 | 56,0 | 57,0 | 58,0 | 58,5 | 59,5 | 59,5 | 60,0 | 59,0 | 59,5 | 60,0 | 60,5 | 61,0 | 61,5 | 61,5 | 62,0 | |
Sound power (Normal mode) | dB(A) | 81,5 | 84,0 | 84,5 | 86,0 | 84,5 | 86,0 | 86,0 | 86,0 | 84,5 | 85,5 | 85,5 | 85,5 | 86,0 | 86,5 | 87,0 | 87,0 | |
Dimension (Height) | mm | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | 1.842 | |
Dimension (Width) | mm | 2.360 (+60) | 2.360 (+60) | 2.360 (+60) | 2.360 (+60) | 2.360 (+60) | 2.360 (+60) | 2.360 (+60) | 2.360 (+60) | 3.540 (+120) | 3.540 (+120) | 3.540 (+120) | 3.540 (+120) | 3.540 (+120) | 3.540 (+120) | 3.540 (+120) | 3.540 (+120) | |
Dimension (Depth) | mm | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | |
Net weight | kg | 523 | 547 | 548 | 574 | 596 | 620 | 668 | 668 | 857 | 881 | 882 | 929 | 930 | 954 | 1.002 | 1.002 | |
Piping diameter (Liquid) (2) | Inch (mm) | 5/8 (15,88) / 3/4 (19,05) | 5/8 (15,88) / 3/4 (19,05) | 5/8 (15,88) / 3/4 (19,05) | 5/8 (15,88) / 3/4 (19,05) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | 3/4 (19,05) / 7/8 (22,22) | |
Piping diameter (Discharge) (2) | Inch (mm) | 7/8 (22,22) / 1 (25,40) | 7/8 (22,22) / 1 (25,40) | 1 (25,40) / 1-1/8 (28,58) | 1 (25,40) / 1-1/8 (28,58) | 1 (25,40) / 1-1/8 (28,58) | 1-1/8 (28,58) / 1-1/4 (31,75) | 1-1/8 (28,58) / 1-1/4 (31,75) | 1-1/8 (28,58) / 1-1/4 (31,75) | 1-1/8 (28,58) / 1-1/4 (31,75) | 1-1/8 (28,58) / 1-1/4 (31,75) | 1-1/4 (31,75) / 1-1/2 (38,10) | 1-1/4 (31,75) / 1-1/2 (38,10) | 1-1/4 (31,75) / 1-1/2 (38,10) | 1-1/4 (31,75) / 1-1/2 (38,10) | 1-1/4 (31,75) / 1-1/2 (38,10) | 1-1/4 (31,75) / 1-1/2 (38,10) | |
Piping diameter (Suction) (2) | Inch (mm) | 1-1/8 (28,58) / 1-1/4 (31,75) | 1-1/8 (28,58) / 1-1/4 (31,75) | 1-1/8 (28,58) / 1-1/4 (31,75) | 1-1/8 (28,58) / 1-1/4 (31,75) | 1-1/4 (31,75) / 1-1/2 (38,10) | 1-1/4 (31,75) / 1-1/2 (38,10) | 1-1/4 (31,75) / 1-1/2 (38,10) | 1-1/4 (31,75) / 1-1/2 (38,10) | 1-1/4 (31,75) / 1-1/2 (38,10) | 1-1/2 (38,10) / 1-5/8 (41,28) | 1-1/2 (38,10) / 1-5/8 (41,28) | 1-1/2 (38,10) / 1-5/8 (41,28) | 1-1/2 (38,10) / 1-5/8 (41,28) | 1-1/2 (38,10) / 1-5/8 (41,28) | 1-1/2 (38,10) / 1-5/8 (41,28) | 1-1/2 (38,10) / 1-5/8 (41,28) | |
Piping diameter (Balance) (2) | Inch (mm) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | |
Refrigerant (R410A) / CO2 Eq. | kg / T | 13,60 / 28,3968 | 15,10 / 31,5288 | 15,10 / 31,5288 | 16,60 / 34,6608 | 15,10 / 31,5288 | 16,60 / 34,6608 | 16,60 / 34,6608 | 16,60 / 34,6608 | 21,90 / 45,72719 | 23,40 / 48,85919 | 23,40 / 48,85919 | 23,40 / 48,85919 | 23,40 / 48,85919 | 24,90 / 46,3536 | 24,90 / 51,9912 | 24,90 / 51,9912 | |
Maximum allowable indoor / outdoor capacity ratio | % | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | 50 ~ 150 | |
Operating range (Cool - Min) | °C | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | |
Operating range (Cool - Max) | °C | +52 | +52 | +52 | +52 | +52 | +52 | +52 | +52 | +52 | +52 | +52 | +52 | +52 | +52 | +52 | +52 | |
Operating range (Heat - Min) | °C | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | |
Operating range (Heat - Max) | °C | +18 | +18 | +18 | +18 | +18 | +18 | +18 | +18 | +18 | +18 | +18 | +18 | +18 | +18 | +18 | +18 | |
Operating range (Simultaneous operation - Min) | °C | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | |
Operating range (Simultaneous operation - Max) | % | +24 | +24 | +24 | +24 | +24 | +24 | +24 | +24 | +24 | +24 | +24 | +24 | +24 | +24 | +24 | +24 |
1) EER and COP calculation is based in accordance to EN14511.
2) Piping diameter under 90m for ultimate indoor unit / over 90m for ultimate indoor unit (if the longest piping equivalent length exceeds 90m, increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes).