3-Pipe ECOi EX MF3 series

Simultaneous heating and cooling operation with heat recovery type

The 3-Pipe ECOi EX MF3 Series is one of the most advanced VRF systems.

Not only high-efficient performance for simultaneous heating and cooling, but also sophisticated installation and maintenance available.

Particularly suitable for retail, hotels and office applications

Specifications

See all
3-Pipe ECOi EX MF3 series THREE PHASE
8 HP 10 HP 12 HP 14 HP 16 HP
Heating capacity (Nominal) kW 25,0 31,5 37,5 45,0 50,0
Sound pressure (Normal mode) dB(A) 54,0 57,0 60,0 61,0 62,0
Sound pressure (Silent mode 1) dB(A) 51,0 54,0 57,0 58,0 59,0
Sound pressure (Silent mode 2) dB(A) 49,0 52,0 55,0 56,0 57,0
Sound power (Normal mode) dB(A) 76,0 78,0 81,0 82,0 82,0
Piping diameter (Liquid) (2) Inch (mm) 3/8 (9,52) / 1/2 (12,70) 3/8 (9,52) / 1/2 (12,70) 1/2 (12,70) / 5/8 (15,88) 1/2 (12,70) / 5/8 (15,88) 1/2 (12,70) / 5/8 (15,88)
Piping diameter (Balance) (2) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Piping diameter (Discharge) (2) Inch (mm) 5/8 (15,88) / 3/4 (19,05) 3/4 (19,05) / 7/8 (22,22) 3/4 (19,05) / 7/8 (22,22) 7/8 (22,22) / 1 (25,40) 7/8 (22,22) / 1 (25,40)
Piping diameter (Suction) (2) Inch (mm) 3/4 (19,05) / 7/8 (22,22) 7/8 (22,22) / 1 (25,40) 1 (25,40) / 1-1/8 (28,58) 1 (25,40) / 1-1/8 (28,58) 1-1/8 (28,58) / 1-1/4 (31,75)
Refrigerant (R410A) / CO2 Eq. kg / T 6,80 / 14,1984 6,80 / 14,1984 8,30 / 17,3304 8,30 / 17,3304 8,30 / 17,3304
Maximum allowable indoor / outdoor capacity ratio % 50 ~ 150 50 ~ 150 50 ~ 150 50 ~ 150 50 ~ 150
Operating range (Simultaneous operation - Min) °C -10 -10 -10 -10 -10
Operating range (Simultaneous operation - Max) % +24 +24 +24 +24 +24
ErP data (3) U-8MF3E8 U-10MF3E8 U-12MF3E8 U-14MF3E8 U-16MF3E8
SEER (4) 7,02 7,05 6,39 6,69 6,02
ηs,c 277,7% 278,9% 252,7% 264,4% 237,7%
SCOP (4) 4,85 4,25 4,27 4,13 3,81
ηs,h 190,9% 166,8% 167,8% 162,1% 149,3%
(1) EER and COP calculation is based in accordance to EN14511.
(2) Piping diameter under 90m for ultimate indoor unit / over 90m for ultimate indoor unit (if the longest piping equivalent length exceeds 90m, increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes).
(3) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units. Eurovent certified.
(4) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.