2-Pipe ECOi EX ME2 series

A VRF system delivering energy-saving performance, powerful operation, reliability and comfort surpassing anything previously possible

It represents a true paradigm shift in air conditioning solutions.

VRF with outstanding energy-saving performance and powerful operation SEER 7,6 (18HP model).

Particularly suitable for retail, hotels and office applications

Specifications

See all
2-Pipe ECOi EX ME2 series THREE PHASE
8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP
ESEER W/W 9,33 8,67 7,94 7,73 7,19 6,95 6,18
Heating capacity (Nominal) kW 25 31,5 37,5 45 50 56 63
Sound pressure (Normal mode) dB(A) 54 56 59 60 61 59 60
Sound pressure (Silent mode) dB(A) 51 53 56 57 58 56 57
Sound pressure (Silent mode 1) dB(A) 51 53 56 57 58 56 57
Sound power (Normal mode) dB(A) 75 77 80 81 82 80 81
Piping diameter (Liquid) (2) Inch (mm) 3/8 (9,52) / 1/2 (12,70) 3/8 (9,52) / 1/2 (12,70) 1/2 (12,70) / 5/8 (15,88) 1/2 (12,70) / 5/8 (15,88) 1/2 (12,70) / 5/8 (15,88) 5/8 (15,88) / 3/4 (19,05) 5/8 (15,88) / 3/4 (19,05)
Piping diameter (Gas) (2) Inch (mm) 3/4 (19,05) / 7/8 (22,22) 7/8 (22,22) / 1 (25,40) 1 (25,40) / 1-1/8 (28,58) 1 (25,40) / 1-1/8 (28,58) 1-1/8 (28,58) / 1-1/4 (31,75) 1-1/8 (28,58) / 1-1/4 (31,75) 1-1/8 (28,58) / 1-1/4 (31,75)
Piping diameter (Balance) (2) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Refrigerant (R410A) / CO2 Eq. kg / T 5,60 / 11,6928 5,60 / 11,6928 8,30 / 17,3304 8,30 / 17,3304 8,30 / 17,3304 9,50 / 19,836 9,50 / 19,836
Maximum allowable indoor / outdoor capacity ratio (3) % 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200) 50 ~ 130 (200)
ErP data (4) U-8ME2E8 U-10ME2E8 U-12ME2E8 U-14ME2E8 U-16ME2E8 U-18ME2E8 U-20ME2E8
SEER (5) 7,43 6,96 6,74 7,23 6,43 7,56 7,03
ηs,c 294,3% 275,4% 266,6% 286,0% 254,3% 299,2% 278,2%
SCOP (5) 4,79 4,27 4,72 4,28 4,05 4,29 4,09
ηs,h 188,4% 167,6% 185,8% 168,2% 159,0% 168,7% 160,4%
(1) EER and COP calculation is based in accordance to EN14511.
(2) Piping diameter under 90m for ultimate indoor unit / over 90m for ultimate indoor unit (if the longest piping equivalent length exceeds 90m, increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes).
(3) If the following conditions are satisfied, the effective range is above 130% and below 200%: A. Obey the limited number of connectable indoor units. B. The lower limit of operating range for heating outdoor temperature is limited to -10°C WB (standard -25°C WB). C. Simultaneous operation is limited to less than 130% of connectable indoor units.
(4) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units. Eurovent certified.
(5) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.