2-Pipe ECOi EX MZ1 Series - R32

2-Pipe ECOi EX MZ1 Series R32

Extreme efficiency, quality, compact.



* Panasonic’s internal research. 12HP model with 30m piping installation.


Best efficiency ECOi Series

Bringing nature’s balance indoors

Specifications

See all
2-Pipe ECOi EX MZ1 Series - R32
10 HP
Outdoor unit U-10MZ1E8
Power supply (Voltage) V 11/06/2245
Power supply (Phase) Three phase
Power supply (Frequency) Hz 50
Cooling capacity (Nominal) kW 28,0,0
EER (1) W/W 3,0,50
Current cooling (1p 220V / 3p 380) A 13,0,50
Current cooling (1p 230V / 3p 400) A 12,0,80
Current cooling (1p 240V / 3p 415) A 12,0,40
Input power cooling kW 8,0,00
Heating capacity (Nominal) kW 31,0,5
COP (1) W/W 4,0,30
Current heating (1p 220V / 3p 380) A 12,0,50
Current heating (1p 230V / 3p 400) A 11,0,90
Current heating (1p 240V / 3p 415) A 11,0,50
Input power heating kW 7,0,32
Starting current A 1,0,00
External static pressure Pa 80
Air flow m³/min 209
Sound pressure (Cool silent 1) dB(A) 57
Sound pressure (Cool silent 2) dB(A) 55
Sound pressure (Cool silent 3) dB(A) 50
Sound power (Cool normal mode) dB(A) 77
Sound power (Heat normal mode) dB(A) 77
Dimension (Height) mm 1,660
Dimension (Width) mm 880
Dimension (Depth) mm 765
Net weight kg 203
Piping diameter (Liquid) (2) Inch (mm) 3/8 (9,52) / 1/2 (12,70)
Piping diameter (Gas) (2) Inch (mm) 3/4 (19,05) / 7/8 (22,22)
Piping diameter (Balance) (2) Inch (mm) 04/01/2000
Refrigerant (R32) / CO2 Eq. kg / T 6,40 / 4,32
Maximum allowable indoor / outdoor capacity ratio (3) % 50 ~ 200 (130)
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C 52
Operating range (Heat - Min) °C -25
Operating range (Heat - Max) °C 24
ErP data (4) -
SEER (5) 7,0,82
ηs,c 310,0,1%
SCOP (5) 4,0,38
ηs,h 172,0,4%

1) EER and COP calculation is based in accordance to EN 14511.
2) Piping diameter under 100m for ultimate indoor unit / over 100m for ultimate indoor unit (if the longest piping equivalent length exceeds 100m, increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes).
3) If the following conditions are satisfied, the effective range is above 130% and below 200%: A. Obey the limited number of connectable indoor units. B. The lower limit of operating range for heating outdoor temperature is limited to -10°C WB (standard -25°C WB). C. Simultaneous operation is limited to less than 130% of connectable indoor units.
4) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for U2 type 4 way 90x90 cassette indoor units.
5) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.