PACi NX Series Elite adaptive ducted unit - PF3 · R32

Design duct range PF3

2 installation possibilities (horizontal / vertical) with high ESP 150Pa allows flexible installation.

* The performance of nanoe™ X air can be expected even by 10m long duct by Panasonic internal survey.

New adaptive ducted PF3

Specifications

See all
PACi NX Series Elite adaptive ducted unit - PF3 · R32
5.80 kW
Kit 60
Indoor unit - 1 S-6071PF3E
Indoor unit - 2
Outdoor unit U-60PZH3E5
Cooling capacity. Outdoor 35°C (DB). Indoor 15°C (WB) kW 5,80
EER. Outdoor 35°C (DB). Indoor 15°C (WB) 3,52
Input power. Outdoor 35°C (DB). Indoor 15°C (WB) kW 1,65
Cooling capacity. Outdoor 35°C (DB). Indoor 12°C (WB) kW 5,28
EER. Outdoor 35°C (DB). Indoor 12°C (WB) 3,26
Input power. Outdoor 35°C (DB). Indoor 12°C (WB) kW 1,62
Cooling capacity. Outdoor 35°C (DB). Indoor 8°C (WB) kW 3,48
EER. Outdoor 35°C (DB). Indoor 8°C (WB) 2,70
Input power. Outdoor 35°C (DB). Indoor 8°C (WB) kW 1,29
Cooling capacity. Outdoor 30°C (DB). Indoor 15°C (WB) kW 5,92
EER. Outdoor 30°C (DB). Indoor 15°C (WB) 3,81
Input power. Outdoor 30°C (DB). Indoor 15°C (WB) kW 1,55
Cooling capacity. Outdoor 30°C (DB). Indoor 12°C (WB) kW 5,39
EER. Outdoor 30°C (DB). Indoor 12°C (WB) 3,55
Input power. Outdoor 30°C (DB). Indoor 12°C (WB) kW 1,52
Cooling capacity. Outdoor 30°C (DB). Indoor 8°C (WB) kW 3,48
EER. Outdoor 30°C (DB). Indoor 8°C (WB) 2,93
Input power. Outdoor 30°C (DB). Indoor 8°C (WB) kW 1,19
Indoor dimension (Height) mm 250
Indoor dimension (Width) mm 1.000
Indoor dimension (Depth) mm 730
Indoor net weight kg 30
nanoe X Generator Mark 2
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 43