Fan coils - Floor Standing chassis (AC)

New range of fan coils. Designed to fit with your environment and enhance comfort

Panasonic introduces the new range of fan coils.

The key to this range is to provide performance and comfort and the ability to fit seamlessly within your environment.

Designed with user in mind, perfectly designed to adapt to any installation. Providing comfort to hotels, shops, restaurants, offices or residential applications.

Technical focus.
· Cooling capacity from 0,7 to 8,1kW
· Heating capacity from 0,7 to 10,3kW
· 5-speed AC fan motor(s)

Main features and accessories.
· 2 and 4-pipe configurations
· Left or right hand arrangements
· Ease of installation
· Very low acoustic levels
· 2 way or 3 way ON/OFF valves
· Auxiliary drain pan
· Air intake with removable grid
· G2 filter
· PAW-FC-SFS feet for floor-standing units

The reasons to choose Panasonic as your partner

Explore the new range of fan coils

Specifications

See all
Fan coils - Floor Standing chassis (AC)
5.8 kW
2-pipe - Left connection PAW-FC2A-P060L
2-pipe - Right connection PAW-FC2A-P060R
Total cooling capacity - 2-pipe (Lo) (1) kW 2,7
Total cooling capacity - 2-pipe (Med) (1) kW 4,6
Total cooling capacity - 2-pipe (Hi) (1) kW 5,8
Sensible cooling capacity - 2-pipe (Lo) (1) kW 1,9
Sensible cooling capacity - 2-pipe (Med) (1) kW 3,3
Sensible cooling capacity - 2-pipe (Hi) (1) kW 4,5
Water flow - 2-pipe (Cooling) (Lo) l/h 466
Water flow - 2-pipe (Cooling) (Med) l/h 784
Water flow - 2-pipe (Cooling) (Hi) l/h 1.003
Water pressure drop - 2-pipe (Cooling) (Lo) kPa 13,9
Water pressure drop - 2-pipe (Cooling) (Med) kPa 37,4
Water pressure drop - 2-pipe (Cooling) (Hi) kPa 60,2
Heating capacity - 2-pipe (Lo) (2) kW 3,1
Heating capacity - 2-pipe (Med) (2) kW 5,3
Heating capacity - 2-pipe (Hi) (2) kW 7,1
4-pipe - Left connection PAW-FC4A-P060L
4-pipe - Right connection PAW-FC4A-P060R
Total cooling capacity - 4-pipe (Lo) (1) kW 2,6
Total cooling capacity - 4-pipe (Med) (1) kW 4,4
Total cooling capacity - 4-pipe (Hi) (1) kW 5,6
Sensible cooling capacity - 4-pipe (Lo) (1) kW 1,8
Sensible cooling capacity - 4-pipe (Med) (1) kW 3,2
Sensible cooling capacity - 4-pipe (Hi) (1) kW 4,3
Water flow - 4-pipe (Cooling) (Lo) l/h 449
Water flow - 4-pipe (Cooling) (Med) l/h 756
Water flow - 4-pipe (Cooling) (Hi) l/h 967
Water pressure drop - 4-pipe (Cooling) (Lo) kPa 10,2
Water pressure drop - 4-pipe (Cooling) (Med) kPa 27,7
Water pressure drop - 4-pipe (Cooling) (Hi) kPa 44,5
Heating capacity - 4-pipe (Lo) (2) kW 1,9
Heating capacity - 4-pipe (Med) (2) kW 2,9
Heating capacity - 4-pipe (Hi) (2) kW 3,7
Water flow (Heating) (Lo) l/h 325
Water flow (Heating) (Med) l/h 505
Water flow (Heating) (Hi) l/h 633
Water pressure drop (Heating) (Lo) kPa 20,3
Water pressure drop (Heating) (Med) kPa 43,9
Water pressure drop (Heating) (Hi) kPa 52,9
Sound levels .
Sound power (Lo) dB(A) 38
Sound power (Med) dB(A) 51
Sound power (Hi) dB(A) 58
Sound pressure (Lo) (3) dB(A) 29
Sound pressure (Med) (3) dB(A) 42
Sound pressure (Hi) (3) dB(A) 49
Fan data .
Number of fans 2
Air flow - 2-pipe (Lo) m³/h 350
Air flow - 2-pipe (Med) m³/h 640
Air flow - 2-pipe (Hi) m³/h 933
Air flow - 4-pipe (Lo) m³/h 334
Air flow - 4-pipe (Med) m³/h 614
Air flow - 4-pipe (Hi) m³/h 885
Filter G2
Electrical data .
Power supply (Voltage) V 230
Power supply (Phase) Single phase
Power supply (Frequency) Hz 50 / 60
Power consumption - 2-pipe (Lo) W 37
Power consumption - 2-pipe (Med) W 75
Power consumption - 2-pipe (Hi) W 105
Power consumption - 4-pipe (Lo) W 37
Power consumption - 4-pipe (Med) W 74
Power consumption - 4-pipe (Hi) W 104
Fan coils water connections .
Type of water connections Female gas threaded
Water connections - 2-pipe Inch 1/2
Water connections - 4-pipe (Cooling) Inch 1/2
Water connections - 4-pipe (Heating) Inch 1/2
Dimensions and weight .
Dimension (Height) mm 477
Dimension (Width) mm 225
Dimension (Depth) mm 1.506
Weight - 2-pipe kg 35
Weight - 4-pipe kg 37

1) According to Eurovent standard. Air: 27°C DB / 19°C WB. Water in/out: 7°C / 12°C.
2) Air: 20°C. Water in/out: 50°C / 45°C.
3) The sound pressure levels are based on (NR) characteristics of a room having volume of 100m³ with reverberation of 0,5 seconds.
* Without support feet.

Complementary products