Fan coils - Floor Standing chassis (AC)

New range of fan coils. Designed to fit with your environment and enhance comfort

Panasonic introduces the new range of fan coils.

The key to this range is to provide performance and comfort and the ability to fit seamlessly within your environment.

Designed with user in mind, perfectly designed to adapt to any installation. Providing comfort to hotels, shops, restaurants, offices or residential applications.

Technical focus.
· Cooling capacity from 0,7 to 8,1kW
· Heating capacity from 0,7 to 10,3kW
· 5-speed AC fan motor(s)

Main features and accessories.
· 2 and 4-pipe configurations
· Left or right hand arrangements
· Ease of installation
· Very low acoustic levels
· 2 way or 3 way ON/OFF valves
· Auxiliary drain pan
· Air intake with removable grid
· G2 filter
· PAW-FC-SFS feet for floor-standing units

The reasons to choose Panasonic as your partner

Explore the new range of fan coils

Specifications

See all
Fan coils - Floor Standing chassis (AC)
1.7 kW
2-pipe - Left connection PAW-FC2A-P020L
2-pipe - Right connection PAW-FC2A-P020R
Total cooling capacity - 2-pipe (Lo) (1) kW 0,7
Total cooling capacity - 2-pipe (Med) (1) kW 1,2
Total cooling capacity - 2-pipe (Hi) (1) kW 1,7
Sensible cooling capacity - 2-pipe (Lo) (1) kW 0,6
Sensible cooling capacity - 2-pipe (Med) (1) kW 0,9
Sensible cooling capacity - 2-pipe (Hi) (1) kW 1,3
Water flow - 2-pipe (Cooling) (Lo) l/h 127
Water flow - 2-pipe (Cooling) (Med) l/h 213
Water flow - 2-pipe (Cooling) (Hi) l/h 289
Water pressure drop - 2-pipe (Cooling) (Lo) kPa 1,9
Water pressure drop - 2-pipe (Cooling) (Med) kPa 3,9
Water pressure drop - 2-pipe (Cooling) (Hi) kPa 6,3
Heating capacity - 2-pipe (Lo) (2) kW 0,9
Heating capacity - 2-pipe (Med) (2) kW 1,5
Heating capacity - 2-pipe (Hi) (2) kW 2,2
4-pipe - Left connection PAW-FC4A-P020L
4-pipe - Right connection PAW-FC4A-P020R
Total cooling capacity - 4-pipe (Lo) (1) kW 0,6
Total cooling capacity - 4-pipe (Med) (1) kW 1,1
Total cooling capacity - 4-pipe (Hi) (1) kW 1,6
Sensible cooling capacity - 4-pipe (Lo) (1) kW 0,5
Sensible cooling capacity - 4-pipe (Med) (1) kW 0,8
Sensible cooling capacity - 4-pipe (Hi) (1) kW 1,2
Water flow - 4-pipe (Cooling) (Lo) l/h 109
Water flow - 4-pipe (Cooling) (Med) l/h 192
Water flow - 4-pipe (Cooling) (Hi) l/h 268
Water pressure drop - 4-pipe (Cooling) (Lo) kPa 1,5
Water pressure drop - 4-pipe (Cooling) (Med) kPa 3,4
Water pressure drop - 4-pipe (Cooling) (Hi) kPa 5,6
Heating capacity - 4-pipe (Lo) (2) kW 0,6
Heating capacity - 4-pipe (Med) (2) kW 0,9
Heating capacity - 4-pipe (Hi) (2) kW 1,1
Water flow (Heating) (Lo) l/h 100
Water flow (Heating) (Med) l/h 146
Water flow (Heating) (Hi) l/h 190
Water pressure drop (Heating) (Lo) kPa 1,5
Water pressure drop (Heating) (Med) kPa 3,2
Water pressure drop (Heating) (Hi) kPa 5,3
Sound levels .
Sound power (Lo) dB(A) 31
Sound power (Med) dB(A) 43
Sound power (Hi) dB(A) 50
Sound pressure (Lo) (3) dB(A) 22
Sound pressure (Med) (3) dB(A) 34
Sound pressure (Hi) (3) dB(A) 41
Fan data .
Number of fans 1
Air flow - 2-pipe (Lo) m³/h 105
Air flow - 2-pipe (Med) m³/h 179
Air flow - 2-pipe (Hi) m³/h 265
Air flow - 4-pipe (Lo) m³/h 89
Air flow - 4-pipe (Med) m³/h 161
Air flow - 4-pipe (Hi) m³/h 241
Filter G2
Electrical data .
Power supply (Voltage) V 230
Power supply (Phase) Single phase
Power supply (Frequency) Hz 50 / 60
Power consumption - 2-pipe (Lo) W 10
Power consumption - 2-pipe (Med) W 18
Power consumption - 2-pipe (Hi) W 29
Power consumption - 4-pipe (Lo) W 10
Power consumption - 4-pipe (Med) W 18
Power consumption - 4-pipe (Hi) W 28
Fan coils water connections .
Type of water connections Female gas threaded
Water connections - 2-pipe Inch 1/2
Water connections - 4-pipe (Cooling) Inch 1/2
Water connections - 4-pipe (Heating) Inch 1/2
Dimensions and weight .
Dimension (Height) mm 766
Dimension (Width) mm 225
Dimension (Depth) mm 477
Weight - 2-pipe kg 19
Weight - 4-pipe kg 20

1) According to Eurovent standard. Air: 27°C DB / 19°C WB. Water in/out: 7°C / 12°C.
2) Air: 20°C. Water in/out: 50°C / 45°C.
3) The sound pressure levels are based on (NR) characteristics of a room having volume of 100m³ with reverberation of 0,5 seconds.
* Without support feet.