RAC Solo · R290 / R32
The compact air conditioner without outdoor unit
- Slim and compact full metal body. Only 16,5cm deep (indoor)
- No outdoor unit. Just two 162mm holes*
- Heating and cooling or cooling only modes available
- DC Inverter technology
- Easy and flexible installation: Stand‑alone unit with no refrigerant connections
- Self-closing grille. Open only during operation
* 202mm for the biggest capacity.

No outdoor unit. Just two 162mm holes*
The RAC Solo range offers great installation flexibility as it is a stand-alone unit with no refrigerant connections during installation. The outdoor unit is replaced by two holes in the wall.
* 202mm for the biggest capacity.

Easy and flexible installation
All you need is a perimeter wall, to exchange air with the outside. The unit can be placed high on the wall or low on the floor.
a. Down installation / b. Overhead installation.

AR Heat Pump Viewer
Interested to see how a Panasonic Air Conditioner looks in your home?
Try the new Panasonic AR projector, utilising augmented reality!
Specifications
RAC Solo · R290 / R32 | |||
---|---|---|---|
1.7 kW | |||
Model | P-MOG16IC5-E | ||
Cooling capacity (Nominal) | kW | 1,73 | |
Cooling capacity (Min) | kW | 0,70 | |
Cooling capacity (Max) | kW | 2,35 | |
EER (1) | W/W | 3,01 | |
SEER (2) | 4,60 B | ||
Input power cooling | kW | 0,57 | |
Heating capacity (Nominal) | kW | 1,71 | |
Heating capacity (Min) | kW | 0,75 | |
Heating capacity (Max) | kW | 2,40 | |
Heating capacity at -7°C | kW | 1,13 | |
COP (1) | W/W | 3,15 | |
SCOP (2) | 3,70 A | ||
Input power heating | kW | 0,54 | |
Power supply | V | 230 | |
Maximum current | A | 3,90 | |
Air flow (Max) | m³/h | 6,0 | |
Air flow (Med) | m³/min | 5,0 | |
Air flow (Min) | m³/h | 4,0 | |
External air flow (Max) | m³/min | 7,2 | |
External air flow (Med) | m³/min | 6,0 | |
External air flow (Min) | m³/min | 5,3 | |
Moisture removal volume | L/h | 0,7 | |
Sound pressure (Hi) (3) | dB(A) | 39 | |
Sound pressure (Lo) (3) | dB(A) | 29 | |
Sound pressure (Q-Lo) (3) | dB(A) | 27 | |
Outside sound pressure (Hi) (3) | dB(A) | 49 | |
Outside sound pressure (Lo) (3) | dB(A) | 36 | |
Refrigerant / charge | kg | R290 / 0,14 | |
Dimension (Height) | mm | 549 | |
Dimension (Width) | mm | 810 | |
Dimension (Depth) | mm | 165 | |
Net weight | kg | 38 | |
Wall hole diameter | mm | 162 | |
Distance between wall holes | mm | 293 | |
Operating range (Cool - Min) | °C | -5 | |
Operating range (Cool - Max) | °C | +43 | |
Operating range (Heat - Min) | °C | -15 | |
Operating range (Heat - Max) | °C | +18 |
1) EER and COP calculation is based in accordance to EN 14511.
2) Energy Label Scale from A+++ to D.
3) The sound pressure shows the value measured at 2m, according to ISO 7779.