Aquarea Air Smart fan coil floor standing

Aquarea Air Smart fan coil floor standing

Designed to provide both heating and cooling in one compact unit, Aquarea Air Smart fan coils maximise energy savings when combined with an Aquarea Heat Pumps.

Specifications

See all
Aquarea Air Smart fan coil floor standing
2.12 kW
Model P-FAL20
Fan speed (1) Min / Med / Max
Total cooling capacity (Min) (2) kW 0,75
Total cooling capacity (Med) (2) kW 1,36
Total cooling capacity (Max) (2) kW 2,12
Sensible capacity (Min) (2) kW 0,59
Sensible capacity (Med) (2) kW 1,04
Sensible capacity (Max) (2) kW 1,54
Water flow cooling (Min) (2) l/h 128,50
Water flow cooling (Med) (2) l/h 233,01
Water flow cooling (Max) (2) l/h 363,22
Water pressure drop cooling (Min) (2) kPa 1,9
Water pressure drop cooling (Med) (2) kPa 4,3
Water pressure drop cooling (Max) (2) kPa 8,2
Heating capacity (Min) (3) kW 0,82
Heating capacity (Med) (3) kW 1,50
Heating capacity (Max) (3) kW 2,19
Water flow heating (Min) (3) l/h 144,60
Water flow heating (Med) (3) l/h 269,80
Water flow heating (Max) (3) l/h 389,71
Water pressure drop heating (Min) (3) kPa 1,5
Water pressure drop heating (Med) (3) kPa 4,3
Water pressure drop heating (Max) (3) kPa 9,2
Sound levels .
Sound power (Min) dB(A) 37
Sound power (Med) dB(A) 47
Sound power (Max) dB(A) 54
Sound pressure (Min) (4) dB(A) 25
Sound pressure (Med) (4) dB(A) 34
Sound pressure (Max) (4) dB(A) 42
Ventilation .
Number of fans 1
Air flow (Min) m³/h 124
Air flow (Med) m³/min 210
Air flow (Max) m³/h 294
Single zone air flow (Min) m³/h 10
Electrical data .
Power supply (Voltage) V 230
Power supply (Phase) 1
Power supply (Frequency) Hz 50
Consumption (Min) W 14,0
Consumption (Med) W 18,0
Consumption (Max) W 22,0
Fan coils water connections .
Hydraulic connections type Eurokonus
Hydraulic connections Inch ¾
Dimensions and weight .
Dimension (Height) mm 580
Dimension (Width) mm 880
Dimension (Depth) mm 119
Net weight kg 16

1) Fan standard factory set speeds.
2) According to Eurovent standard. Air: 27°C DB/19°C WB, chilled water: 7°C/12°C (for water pressure drop data: pressure loss by corresponding nominal flow).
3) According to Eurovent standard. Air: 20°C, hot water: 45°C/40°C. Pressure loss by corresponding nominal flow (for water pressure drop data: pressure loss by corresponding nominal flow).
4) Informative data
, considering an hypothetical sound attenuation of the room and installation of 9dB(A).