Bi-bloc K Series 3 phase · R32

Aquarea High Performance Bi-bloc K Series Three phase

A revolution in design, efficiency, connectivity and sustainability.
Aquarea K Series is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance. This model is ideal for new installations and well-insulated homes.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.

Owning an Aquarea?

Specifications

See all
Bi-bloc K Series 3 phase · R32
16 kW
Kit 9kW electric heater KIT-WC16K9E8
Heating capacity (A +7°C, W 35°C) kW 16,00
COP (A +7°C, W 35°C) 4,31
Heating capacity (A +7°C, W 55°C) kW 14,70
COP (A +7°C, W 55°C) 2,72
Heating capacity (A +2°C, W 35°C) kW 13,20
COP (A +2°C, W 35°C) 3,28
Heating capacity (A +2°C, W 55°C) kW 10,00
COP (A +2°C, W 55°C) 2,21
Heating capacity (A -7°C, W 35°C) kW 11,60
COP (A -7°C, W 35°C) 2,57
Heating capacity (A -7°C, W 55°C) kW 9,10
COP (A -7°C, W 55°C) 1,85
Cooling capacity (A 35°C, W 7°C) kW 13,40
EER (A 35°C, W 7°C) 2,64
Cooling capacity (A 35°C, W 18°C) kW 15,50
EER (A 35°C, W 18°C) 3,60
Heating average climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,46 / 3,40
Heating average climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 176 / 133)
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating cold climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 6,20 / 4,30
Heating cold climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 245 / 16)
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Heating warm climate. Seasonal energy efficiency SCOP (W 35°C / W 55°C) SCOP 4,28 / 3,10
Heating warm climate. Seasonal energy efficiency η (W 35°C / W 55°C) ηs % 168 / 121)
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+
Indoor unit 3kW electric heater
Indoor unit 9kW electric heater WH-SDC16K9E8
Indoor sound pressure (Heat) dB(A) 33
Indoor sound pressure (Cool) dB(A) 33
Indoor dimension (Height) mm 892
Indoor dimension (Width) mm 500
Indoor dimension (Depth) mm 348
Indoor net weight kg 41
Water pipe connector Inch R 1¼
A class pump (Number of speeds) Variable speed
A class pump (Input power) W 145
Heating water flow (∆T=5 K. 35°C) L/min 45,9
Outdoor unit WH-UDZ16KE8
Outdoor sound power (Heat) (2) dB(A) 65
Outdoor dimension (Height) mm 1.340
Outdoor dimension (Width) mm 900
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 103
Refrigerant (R32) / CO2 Eq. kg / T 1,83 / 1,235
Piping diameter (Liquid) Inch (mm) 1/4 (6,35)
Piping diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 30
Elevation difference (in/out) m 20
Pre-charged pipe length m 10
Additional gas amount g/m 30
Operation range - Outdoor ambient (Heat) °C -25 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43
Water outlet (Heat) (3) °C 20 ~ 60
Water outlet (Cool) (3) °C 5 ~ 20
Electrical information 9kW
Electric backup heater kW 9,00
Recommended fuse A 20 / 20
Recommended minimum cable size, supply 1 (4) mm² 5x2,5
Recommended minimum cable size, supply 2 (4) mm² 5x1,5

1) Scale from A+++ to D.
2) Sound power level in accordance to EN12102 under conditions of the EN14825.
3) Operation range down to -25°C in heating with 3 ~ 40m pipe length range, operation range down to -15°C in heating with 3 ~ 50m pipe length range.
4) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
*** Available in Summer 2024. Tentative data.

Complementary products