PACi NX Series Standard ceiling Inverter+ - R32

Ceiling mounted units provide large and wide air distribution which is good for big rooms

The height and depth of all capacities are the same for unified appearance in mixed installations.

The next generation of commercial air conditioners is here

Specifications

See all
PACi NX Series Standard ceiling Inverter+ - R32
10.0 kW
Kit KIT-100PT3Z8
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 10,0
Cooling capacity (Min) kW 3,0
Cooling capacity (Max) kW 11,5
EER (Nominal) (1) W/W 3,64
SEER/ηs,c (2) % 6,5 A++
Pdesign (cooling) kW 10,0
Input power cooling (Nominal) kW 2,75
Annual energy consumption cooling (3) kWh/a 537
Heating capacity (Nominal) kW 10,0
Heating capacity (Min) kW 3,0
Heating capacity (Max) kW 14,0
COP (Nominal) (1) W/W 4,24
SCOP/ηs,h (2) % 4,2 A+
Pdesign at -10°C kW 10,0
Input power heating (Nominal) kW 2,36
Annual energy consumption heating (3) kWh/a 3.331
Indoor unit S-1014PT3E
Indoor air flow (Hi) m³/min 30,0
Indoor air flow (Med) m³/min 25,0
Indoor air flow (Lo) m³/min 23,0
Moisture removal volume L/h 4,1
Indoor sound pressure (Med) (4) dB(A) 37
Indoor sound pressure (Lo) (4) dB(A) 34
Indoor sound power (Hi) dB(A) 60
Indoor sound power (Med) dB(A) 55
Indoor sound power (Lo) dB(A) 52
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1.590
Indoor dimension (Depth) mm 690
Indoor net weight kg 40
nanoe X Generator Mark 2
Outdoor unit U-100PZ3E8
Outdoor power source V 380 - 400 - 415
Current cooling (1p 220V / 3p 380) A 4,60
Current cooling (1p 230V / 3p 400) A 4,35
Current cooling (1p 240V / 3p 415) A 4,20
Current heating (1p 220V / 3p 380) A 3,95
Current heating (1p 230V / 3p 400) A 3,75
Current heating (1p 240V / 3p 415) A 3,60
Outdoor air flow (Cool) m³/min 73,0
Outdoor air flow (Heat) m³/min 73,0
Outdoor sound pressure (Cool - Hi) dB(A) 52
Outdoor sound pressure (Heat - Hi) dB(A) 52
Outdoor sound power (Cool -Hi) dB(A) 70
Outdoor sound power (Heat -Hi) dB(A) 70
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 83
Piping diameter (Liquid) Inch (mm) 3/8 (9,52)
Piping diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 50
Elevation difference (in/out) (7) m 15 / 30 (8)
Pre-charged pipe length m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 2,40 / 1,62
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

1) EER and COP calculation is based in accordance to EN14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηsc / ηsh values is calculated based on EN 14825.
3) Factory setting.
4) The sound pressure of the units shows the value measured of the position 1m in front of the main body and 1m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit.
7) When installing the outdoor unit at a higher position than the indoor unit.
8) Outdoor unit located lower / outdoor unit located higher.
* Recommended fuse for the indoor 3A.
** Above values are in the case of nanoe™ X OFF.

Complementary products