Free Multi System Z · R32

Free Multi System Z · R32

Full flexibility up to 9,0 kW and up to 5 ports with wide range of indoor units including high performance Etherea indoor units, reaching up to A+++ / A++.

The air conditioning connects with the future

Specifications

See all
Free Multi System Z · R32
4.10 kW
Outdoor unit CU-2Z41TBE
Indoor nominal capacity (Min ~ Max) kW 3,2 ~ 6,0
Cooling capacity (Nominal) kW 4,10
Cooling capacity (Min) kW 1,50
Cooling capacity (Max) kW 5,20
EER (Nominal) (1) W/W 4,56
EER (Min) (1) W/W 6,00
EER (Max) (1) W/W 3,80
SEER (2) 8,50 A+++
Pdesign (cooling) kW 4,10
Input power cooling (Nominal) kW 0,90
Input power cooling (Min) kW 0,25
Input power cooling (Max) kW 1,37
Annual energy consumption cooling (3) kWh/a 169
Heating capacity (Nominal) kW 4,60
Heating capacity (Min) kW 1,10
Heating capacity (Max) kW 7,00
Heating capacity at -7°C kW
COP (Nominal) (1) W/W 4,79
COP (Min) (1) W/W 5,24
COP (Max) (1) W/W 3,91
SCOP (2) 4,60 A++
Pdesign at -10°C kW 3,50
Input power heating (Nominal) kW 0,96
Input power heating (Min) kW 0,21
Input power heating (Max) kW 1,79
Annual energy consumption heating (3) kWh/a 1.065
Power supply (Voltage) V 230
Current cooling A 4,15
Current heating A 4,45
Outdoor recommended fuse A 16
Recommended power cable section mm² 2,5
Outdoor sound pressure (Cool - Hi) (4) dB(A) 48
Outdoor sound pressure (Heat - Hi) (4) dB(A) 50
Outdoor dimension (Height) (5) mm 619
Outdoor dimension (Width) (5) mm 824
Outdoor dimension (Depth) (5) mm 299
Outdoor net weight kg 39
Piping diameter (Liquid) Inch (mm) 1/4 (6,35)
Piping diameter (Gas) Inch (mm) 3/8 (9,52)
Pipe length range total (6) m 6 ~ 30
Pipe length range to one unit m 3 ~ 20
Elevation difference (in/out) m 10
Pre-charged pipe length m 20
Additional gas amount g/m 15
Refrigerant (R32) / CO2 Eq. kg / T 1,12 / 0,756
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +46
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

1) EER and COP calculation is based in accordance to EN14511.
2) Energy Label Scale from A+++ to D.
3) The annual energy consumption is calculated in accordance to EU/626/2011.
4) The sound pressure of the units shows the value measured of a position 1m in front and 1m in rear side of the main body. The sound pressure is measured in accordance with JISC9612.
5) Add 70 or 95mm for piping port.
6) Minimum piping length is 3 meters per indoor unit.