Floor Console Inverter+ • R32
Floor Console. Efficient comfort and clean air all year round.
Floor Console with new nanoe™ X technology: outstanding efficiency A++, comfort (Super Quiet technology only 20 dB(A)) and healthy air combined in a breakthrough design.
- nanoe™ X, technology with the benefits of hydroxyl radicals, improve protection 24/7
- Infrared control Sky Controller
- A breakthrough design that integrates perfectly with the most modern environments. We have selected the finest materials and processes for a refined design
- High energy efficiency class up to A++
- Control your comfort and the power consumption with internet control
En yeni nesil klima sistemini keşfedin
Büyük tasarruflar ve iyileştirilmiş sağlık
Klimalarımız, çok az bir enerji maliyetiyle en üst konforu üretir ve virüslerden, bakterilerden, polen ve kokulardan arındırılmış temiz bir hava oluşturur.
Sizin için tasarlanmış bir ürün yelpazesi
Daha küçük 1X1'den daha bütün 5x1 çözümlere kadar, ihtiyacınızın ne olduğu hiç fark etmez. Panasonic, evinizde en iyi iklimi sağlamak size en iyi çözümü sunabilir.
Tüm sene boyunca rahat bir ev
Klimalarımız tüm sene boyunca size en konforlu sıcaklığı sağlar; kışın ısıtmayı, yazın soğutmayı ve bütün yıl ortamın temizlenmesini sağlar.
Büyük tasarruflar ve iyileştirilmiş sağlık
Klimalarımız, çok az bir enerji maliyetiyle en üst konforu üretir ve virüslerden, bakterilerden, polen ve kokulardan arındırılmış temiz bir hava oluşturur.
Sizin için tasarlanmış bir ürün yelpazesi
Daha küçük 1X1'den daha bütün 5x1 çözümlere kadar, ihtiyacınızın ne olduğu hiç fark etmez. Panasonic, evinizde en iyi iklimi sağlamak size en iyi çözümü sunabilir.
Tüm sene boyunca rahat bir ev
Klimalarımız tüm sene boyunca size en konforlu sıcaklığı sağlar; kışın ısıtmayı, yazın soğutmayı ve bütün yıl ortamın temizlenmesini sağlar.
Klima sistemleri gelecekle bağlantı kuruyor
Doğanın dengesini iç mekana getirir
Teknik Özellikler
Floor Console Inverter+ • R32 | |||
---|---|---|---|
5 kW | |||
Kit | KIT-Z50-UFE | ||
Cooling capacity (Nominal) | kW | 5,00 | |
Cooling capacity (Min) | kW | 0,90 | |
Cooling capacity (Max) | kW | 5,70 | |
EER (Nominal) (1) | W/W | 3,60 | |
EER (Min) (1) | W/W | 3,53 | |
EER (Max) (1) | W/W | 3,15 | |
SEER (2) | 6,70 A++ | ||
Pdesign (cooling) | kW | 5,00 | |
Input power cooling (Nominal) | kW | 1,39 | |
Input power cooling (Min) | kW | 0,26 | |
Input power cooling (Max) | kW | 1,81 | |
Annual energy consumption cooling (3) | kWh/a | 261,00 | |
Heating capacity (Nominal) | kW | 5,80 | |
Heating capacity (Min) | kW | 0,90 | |
Heating capacity (Max) | kW | 8,10 | |
Heating capacity at -7°C | kW | 5,03 | |
COP (Nominal) (1) | W/W | 3,74 | |
COP (Min) (1) | W/W | 3,46 | |
COP (Max) (1) | W/W | 3,12 | |
SCOP (2) | 4,30 A+ | ||
Pdesign at -10°C | kW | 4,40 | |
Input power heating (Nominal) | kW | 1,55 | |
Input power heating (Min) | kW | 0,26 | |
Input power heating (Max) | kW | 2,60 | |
Annual energy consumption heating (3) | kWh/a | 1433 | |
Indoor unit | CS-Z50UFEAW | ||
Indoor power source | V | 230 | |
Indoor air flow (Cool) | m³/min | 11,6 | |
Indoor air flow (Heat) | m³/min | 13,2 | |
Moisture removal volume | L/h | 2,8 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 44 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 44 | |
Indoor sound pressure (Cool -Lo) (4) | dB(A) | 31 | |
Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 27 | |
Indoor sound pressure (Heat -Hi) (4) | dB(A) | 46 | |
Indoor sound pressure (Heat -Lo) (4) | dB(A) | 33 | |
Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 29 | |
Indoor dimension (Height) | mm | 600 | |
Indoor dimension (Width) | mm | 750 | |
Indoor dimension (Depth) | mm | 207 | |
Indoor net weight | kg | 13 | |
nanoe X Generator | Mark 1 | ||
Outdoor unit | CU-Z50UBEA | ||
Outdoor power source | V | 230 | |
Outdoor recommended fuse | A | 16 | |
Outdoor connection indoor / outdoor | mm² | — | |
Outdoor air flow (Cool) | m³/min | 39,7 | |
Outdoor air flow (Heat) | m³/min | 38,6 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 48 | |
Outdoor dimension (Height) (5) | mm | 695 | |
Outdoor dimension (Width) (5) | mm | 875 | |
Outdoor dimension (Depth) (5) | mm | 320 | |
Outdoor net weight | kg | 43 | |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | |
Pipe length range | m | 3 ~ 30 | |
Elevation difference (in/out) (6) | m | 20 | |
Pipe length for additional gas | m | 7,5 | |
Additional gas amount | g/m | 15 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,13 / 0,763 | |
Operating range (Cool - Min) | °C | -10 | |
Operating range (Cool - Min) | °C | -10 | |
Operating range (Cool - Max) | °C | +43 | |
Operating range (Heat - Min) | °C | -15 | |
Operating range (Heat - Max) | °C | +24 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of a position 1 m in front of the main body and 1 m above floor. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.