4-Way 60x60 Cassette Inverter • R32
Specially designed for offices, retail and restaurant applications, this Cassette fits perfectly into 60x60 or 70x70 ceiling grids.
- Cassettes can be controlled by KNX and Modbus
- Designed for easy installation in the standard European 60x60 ceiling grid
- Piping length up to 30 m
- Maximum elevation difference up to 20 m
- Compact outdoor units for easy installation
- High pressure selector in case of high ceilings (higher than 2,7 m)
- Drain pump included (maximum 750 mm high)
- Air fresh entry available on the Cassette
En yeni nesil klima sistemini keşfedin
Büyük tasarruflar ve iyileştirilmiş sağlık
Klimalarımız, çok az bir enerji maliyetiyle en üst konforu üretir ve virüslerden, bakterilerden, polen ve kokulardan arındırılmış temiz bir hava oluşturur.
Sizin için tasarlanmış bir ürün yelpazesi
Daha küçük 1X1'den daha bütün 5x1 çözümlere kadar, ihtiyacınızın ne olduğu hiç fark etmez. Panasonic, evinizde en iyi iklimi sağlamak size en iyi çözümü sunabilir.
Tüm sene boyunca rahat bir ev
Klimalarımız tüm sene boyunca size en konforlu sıcaklığı sağlar; kışın ısıtmayı, yazın soğutmayı ve bütün yıl ortamın temizlenmesini sağlar.
Büyük tasarruflar ve iyileştirilmiş sağlık
Klimalarımız, çok az bir enerji maliyetiyle en üst konforu üretir ve virüslerden, bakterilerden, polen ve kokulardan arındırılmış temiz bir hava oluşturur.
Sizin için tasarlanmış bir ürün yelpazesi
Daha küçük 1X1'den daha bütün 5x1 çözümlere kadar, ihtiyacınızın ne olduğu hiç fark etmez. Panasonic, evinizde en iyi iklimi sağlamak size en iyi çözümü sunabilir.
Tüm sene boyunca rahat bir ev
Klimalarımız tüm sene boyunca size en konforlu sıcaklığı sağlar; kışın ısıtmayı, yazın soğutmayı ve bütün yıl ortamın temizlenmesini sağlar.
Klima sistemleri gelecekle bağlantı kuruyor
Teknik Özellikler
4-Way 60x60 Cassette Inverter • R32 | |||
---|---|---|---|
5 kW | |||
Kit | KIT-Z50-UB4 | ||
Cooling capacity (Nominal) | kW | 5,00 | |
Cooling capacity (Min) | kW | 0,90 | |
Cooling capacity (Max) | kW | 5,80 | |
EER (Nominal) (1) | W/W | 3,25 | |
EER (Min) (1) | W/W | 3,53 | |
EER (Max) (1) | W/W | 3,09 | |
SEER (2) | 6,40 A++ | ||
Pdesign (cooling) | kW | 5,00 | |
Input power cooling (Nominal) | kW | 1,54 | |
Input power cooling (Min) | kW | 0,26 | |
Input power cooling (Max) | kW | 1,88 | |
Annual energy consumption cooling (3) | kWh/a | 273,00 | |
Heating capacity (Nominal) | kW | 5,60 | |
Heating capacity (Min) | kW | 0,90 | |
Heating capacity (Max) | kW | 7,10 | |
Heating capacity at -7°C | kW | 4,40 | |
COP (Nominal) (1) | W/W | 3,03 | |
COP (Min) (1) | W/W | 3,46 | |
COP (Max) (1) | W/W | 2,95 | |
SCOP (2) | 4,30 A+ | ||
Pdesign at -10°C | kW | 3,80 | |
Input power heating (Nominal) | kW | 1,85 | |
Input power heating (Min) | kW | 0,26 | |
Input power heating (Max) | kW | 2,41 | |
Annual energy consumption heating (3) | kWh/a | 1237 | |
Indoor unit | CS-Z50UB4EAW | ||
Panel | CZ-BT20EW | ||
Indoor power source | V | 230 | |
Indoor air flow (Cool) | m³/min | 11,5 | |
Indoor air flow (Heat) | m³/min | 11,8 | |
Moisture removal volume | L/h | 2,8 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 37 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 37 | |
Indoor sound pressure (Cool -Lo) (4) | dB(A) | 28 | |
Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 25 | |
Indoor sound pressure (Heat -Hi) (4) | dB(A) | 38 | |
Indoor sound pressure (Heat -Lo) (4) | dB(A) | 29 | |
Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 26 | |
Indoor dimension (Height) | mm | 260 | |
Indoor dimension (Width) | mm | 575 | |
Indoor dimension (Depth) | mm | 575 | |
Panel dimension (Height) | mm | 51 | |
Panel dimension (Depth) | mm | 700 | |
Indoor net weight | kg | 18 | |
Panel net weight | kg | 2,5 | |
Outdoor unit | CU-Z50UBEA | ||
Outdoor power source | V | 230 | |
Outdoor recommended fuse | A | — | |
Outdoor connection indoor / outdoor | mm² | — | |
Outdoor air flow (Cool) | m³/min | 39,7 | |
Outdoor air flow (Heat) | m³/min | 38,6 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 48 | |
Outdoor dimension (Height) (5) | mm | 695 | |
Outdoor dimension (Width) (5) | mm | 875 | |
Outdoor dimension (Depth) (5) | mm | 320 | |
Outdoor net weight | kg | 43 | |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | |
Pipe length range | m | 3 ~ 30 | |
Elevation difference (in/out) (6) | m | 20 | |
Pipe length for additional gas | m | 7,5 | |
Additional gas amount | g/m | 15 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,13 / 0,763 | |
Operating range (Cool - Min) | °C | -10 | |
Operating range (Cool - Min) | °C | -10 | |
Operating range (Cool - Max) | °C | +43 | |
Operating range (Heat - Min) | °C | -15 | |
Operating range (Heat - Max) | °C | +24 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position 1,5 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.