Nástenný superkompaktný menič BZ

BZ je kompaktný a tichý nástenný splitový rad s filtrom PM2,5 a vysokými štandardnými špecifikáciami.

Špecifikácie

Pozri všetky
BZ superkompakt - R32
5.00 kW
Kit KIT-BZ50-ZKE
Cooling capacity (Min) kW 0,98
Cooling capacity (Max) kW 5,40
EER (Nominal) (1) W/W 3,03
EER (Min) (1) W/W 3,92
EER (Max) (1) W/W 2,90
Pdesign (cooling) kW 5
Input power cooling (Nominal) kW 1,65
Input power cooling (Min) kW 0,25
Input power cooling (Max) kW 1,86
Annual energy consumption cooling (3) kWh/a 269
Heating capacity (Min) kW 0,98
Heating capacity (Max) kW 7,50
Heating capacity at -7°C kW 4,62
COP (Nominal) (1) W/W 3,42
COP (Min) (1) W/W 4,67
COP (Max) (1) W/W 3,09
Pdesign at -10°C kW 4
Input power heating (Nominal) kW 1,58
Input power heating (Min) kW 0,21
Input power heating (Max) kW 2,43
Annual energy consumption heating (3) kWh/a 1.333
Indoor unit CS-BZ50ZKE
Indoor power source V 230
Indoor recommended fuse A 16
Indoor connection indoor / outdoor mm² 4 x 2,5
Indoor air flow (Cool) m³/min 12,5
Indoor air flow (Heat) m³/min 13,2
Moisture removal volume L/h 2,8
Indoor sound pressure (Cool - Hi) (4) dB(A) 44
Indoor sound pressure (Cool - Hi) (4) dB(A) 44
Indoor sound pressure (Cool - Lo) (4) dB(A) 37
Indoor sound pressure (Cool - Q-Lo) (4) dB(A) 34
Indoor sound pressure (Heat - Hi) (4) dB(A) 44
Indoor sound pressure (Heat - Lo) (4) dB(A) 37
Indoor sound pressure (Heat - Q-Lo) (4) dB(A) 34
Indoor dimension (Height) mm 290
Indoor dimension (Width) mm 779
Indoor dimension (Depth) mm 209
Indoor net weight kg 8
Outdoor air flow (Cool) m³/min 32,7
Outdoor air flow (Heat) m³/min 32,7
Outdoor sound pressure (Cool - Hi) (4) dB(A) 48
Outdoor sound pressure (Cool - Hi) (4) dB(A) 48
Outdoor sound pressure (Heat - Hi) (4) dB(A) 49
Outdoor dimension (Height) (5) mm 619
Outdoor dimension (Width) (5) mm 824
Outdoor dimension (Depth) (5) mm 299
Outdoor net weight kg 35
Piping diameter (Liquid) Inch (mm) 1/4 (6,35)
Piping diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 15
Elevation difference (in/out) (6) m 15
Pre-charged pipe length m 10
Additional gas amount g/m 15

1) Výpočet EER a COP je založený na norme EN14511.
2) Stupnica energetických štítkov od A+++ po D.
3) Ročná spotreba energie je vypočítaná v súlade s EÚ/626/2011.
4) Akustický tlak vnútornej jednotky uvádza hodnotu nameranú z polohy 1 m pred hlavným telesom a 0,8 m pod jednotkou. V prípade vonkajšej jednotky 1 m vpredu a 1 m vzadu na strane hlavného telesa. Akustický tlak sa meria v súlade s normou JIS C 9612. Q-Lo: Tichý režim. Lo: Najnižšia nastavená rýchlosť ventilátora.
5) Pridajte 70 mm pre potrubný port.

Doplnkové Produkty