Modeli
Simultaneous heating and cooling operation with heat recovery type
The 3-Pipe ECOi EX MF3 Series is one of the most advanced VRF systems.
Not only high-efficient performance for simultaneous heating and cooling, but also sophisticated installation and maintenance available.
- Upgraded COP 5,23 (average cooling and heating value for 18HP outdoor unit)
- Simultaneous cooling and heating operation with up to 39 indoor units
- Slim heat recovery boxes with just 200mm height fit with the ceiling space limited in hotel applications
- Rotation operation function and back-up operation function provided
- EER, COP: Eurovent certified
- Standardisation of outdoor unit to one compact casing size
- The constant-speed compressor adopts a high-performance internal high-pressure scroll
- Up to 52 indoor units connectable
- High external static pressure 80Pa with a newly designed fan, fan guard, motor, and casing
- Bluefin condenser outdoor unit
Odlično se prilagaja namenom uporabe v trgovskih, hotelskih in pisarniških prostorih



Panasonic: že več let zagotavljamo vrhunsko energetsko učinkovitost
Celovita rešitev VRF za učinkovitost, kakovost in udobje.
Elektrika ali plin ali hibrid? Napredne tehnologije VRF, ki strankam ponujajo optimalno izbiro in prilagodljivost.
Panasonic ECOi je potrjen s strani Euroventa
Potrdilo Eurovent preverja zmogljivosti sistemov ogrevanja in hlajenja v skladu z evropskimi standardi. Ti podatki zagotavljajo učinkovitost izdelkov s popolno preglednostjo v korist kupcev in strokovnjakov.
Panasonic: že več let zagotavljamo vrhunsko energetsko učinkovitost
Celovita rešitev VRF za učinkovitost, kakovost in udobje.
Elektrika ali plin ali hibrid? Napredne tehnologije VRF, ki strankam ponujajo optimalno izbiro in prilagodljivost.
Panasonic ECOi je potrjen s strani Euroventa
Potrdilo Eurovent preverja zmogljivosti sistemov ogrevanja in hlajenja v skladu z evropskimi standardi. Ti podatki zagotavljajo učinkovitost izdelkov s popolno preglednostjo v korist kupcev in strokovnjakov.
Najbolj učinkovita serija ECOi
Tehnični podatki
3-Pipe ECOi EX MF3 series combination from 18 to 48HP | THREE PHASE | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18 kW | 20 kW | 22 kW | 24 kW | 26 kW | 28 kW | 30 kW | 32 kW | 34 kW | 36 kW | 38 kW | 40 kW | 42 kW | 44 kW | 46 kW | 48 kW | |||
EER (Nominal) (1) | W/W | 4,90 | 4,31 | 4,24 | 3,89 | 3,88 | 3,65 | 3,59 | 3,49 | 4,10 | 3,90 | 3,88 | 3,72 | 3,72 | 3,58 | 3,55 | 3,49 | |
COP (Nominal) (1) | W/W | 5,23 | 4,77 | 4,79 | 4,47 | 4,50 | 4,31 | 4,19 | 4,17 | 4,64 | 4,48 | 4,51 | 4,31 | 4,36 | 4,25 | 4,18 | 4,17 | |
Operating range (Cool - Min) | °C | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | |
Operating range (Cool - Min) | °C | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | -10 ~ +52 | |
Cooling capacity (Nominal) | kW | 50,00 | 56,00 | 61,50 | 68,00 | 73,00 | 78,50 | 85,00 | 90,00 | 96,00 | 101,00 | 107,00 | 113,00 | 118,00 | 124,00 | 130,00 | 135,00 | |
Cooling capacity (Nominal) | kW | 50,00 | 56,00 | 61,50 | 68,00 | 73,00 | 78,50 | 85,00 | 90,00 | 96,00 | 101,00 | 107,00 | 113,00 | 118,00 | 124,00 | 130,00 | 135,00 | |
Heating capacity (Nominal) | kW | 56,00 | 63,00 | 69,00 | 76,50 | 81,50 | 87,50 | 95,00 | 100,00 | 108,00 | 113,00 | 119,00 | 127,00 | 132,00 | 138,00 | 145,00 | 150,00 | |
Outdoor power source | V | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | 380 / 400 / 415 | |
Indoor sound pressure (Heat) | dB(A) | 59,00 | 61,00 | 62,00 | 63,00 | 63,50 | 64,50 | 64,50 | 65,00 | 64,00 | 64,50 | 65,00 | 65,50 | 66,00 | 66,50 | 66,50 | 67,00 | |
Dimensions | 1.842 x 2.360 (+60) x 1.000 | 1.842 x 2.360 (+60) x 1.000 | 1.842 x 2.360 (+60) x 1.000 | 1.842 x 2.360 (+60) x 1.000 | 1.842 x 2.360 (+60) x 1.000 | 1.842 x 2.360 (+60) x 1.000 | 1.842 x 2.360 (+60) x 1.000 | 1.842 x 2.360 (+60) x 1.000 | 1.842 x 3.540 (+120) x 1.000 | 1.842 x 3.540 (+120) x 1.000 | 1.842 x 3.540 (+120) x 1.000 | 1.842 x 3.540 (+120) x 1.000 | 1.842 x 3.540 (+120) x 1.000 | 1.842 x 3.540 (+120) x 1.000 | 1.842 x 3.540 (+120) x 1.000 | 1.842 x 3.540 (+120) x 1.000 | ||
Net weight | kg | 523 | 547 | 548 | 574 | 596 | 620 | 668 | 668 | 857 | 881 | 882 | 929 | 930 | 954 | 1.002 | 1.002 | |
Refrigerant (R410A) / CO2 Eq. | kg / T | 13,60 / 28,3968 | 15,10 / 31,5288 | 15,10 / 31,5288 | 16,60 / 34,6608 | 15,10 / 31,5288 | 16,60 / 34,6608 | 16,60 / 34,6608 | 16,60 / 34,6608 | 21,90 / 45,72719 | 23,40 / 48,85919 | 23,40 / 48,85919 | 23,40 / 48,85919 | 23,40 / 48,85919 | 24,90 / 46,3536 | 24,90 / 51,9912 | 24,90 / 51,9912 |
1) EER and COP calculation is based in accordance to EN14511.
2) Piping diameter under 90m for ultimate indoor unit / over 90m for ultimate indoor unit (if the longest piping equivalent length exceeds 90m, increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes).