Stropna naprava PACi Elite • R32

Stropne enote zagotavljajo obsežno in široko razporeditev zraka, kar je odlično za velike prostore. Vse enote so enake višine in globine, tako da so ne glede na vrsto vgradnje enakega videza.

Tehnični podatki

Poglej vse
Stropna naprava PACi Elite • R32
7.1 kW
Kit KIT-71PT2ZH8
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 7,1
Cooling capacity (Min) kW 2,2
Cooling capacity (Max) kW 9,0
EER (Nominal) (1) W/W 3,78
SEER (2) 6,6 A++
Pdesign (cooling) kW 7,1
Input power cooling (Nominal) kW 1,88
Annual energy consumption cooling (3) kWh/a 375
Annual energy consumption cooling (3) kWh/a 375
Heating capacity (Nominal) kW 8,0
Heating capacity (Min) kW 2,0
Heating capacity (Max) kW 9,0
COP (Nominal) (1) W/W 4,15
SCOP (2) 4,6 A++
Pdesign at -10°C kW 5,2
Input power heating (Nominal) kW 1,93
Annual energy consumption heating (3) kWh/a 1583
Indoor unit S-71PT2E5B
Indoor air flow (Hi) m³/min 21,0
Indoor air flow (Med) m³/min 18,0
Indoor air flow (Lo) m³/min 15,5
Indoor sound pressure (Med) (4) dB(A) 35
Indoor sound pressure (Lo) (4) dB(A) 31
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1275
Indoor dimension (Depth) mm 690
Indoor net weight kg 33
Outdoor unit U-71PZH2E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 2,95
Current in cooling (1p 230V / 3p 400) A 2,85
Current in cooling (1p 240V / 3p 415) A 2,75
Current in heating (1p 220V / 3p 380) A 3,00
Current in heating (1p 230V / 3p 400) A 2,90
Current in heating (1p 240V / 3p 415) A 2,80
Outdoor air flow (Cool) m³/min 61
Outdoor air flow (Heat) m³/min 60
Outdoor sound pressure (Cool -Hi) dB(A) 48
Outdoor sound pressure (Heat -Hi) dB(A) 50
Outdoor sound power (Cool -Hi) dB(A) 65
Outdoor sound power (Heat -Hi) dB(A) 67
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 940
Outdoor dimension (Depth) mm 340
Outdoor net weight kg 68
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 50
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 1,95 / 1,316
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C 46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C 24

(1) Izračun EER in COP je izdelan na podlagi EN14511.
(2) Lestvica energijskih nalepk od A+++ do D. Za modele z manj kot 12 kW sta vrednosti SEER in SCOP izračunani na podlagi vrednosti direktive EU/626/2011. Za modele z več kot 12 kW sta vrednosti SEER in SCOP izračunani na podlagi vrednosti direktive EU/2281/2016.
(3) Letna poraba energije je izračunana v skladu z direktivo EU/626/2011.
(4) Zvočni tlak enot prikazuje vrednost, izmerjeno 1 meter pred glavnim ohišjem in 1 meter pod enoto. Zvočni tlak je izmerjen v skladu s tehničnimi navedbami v dokumentu Eurovent 6/C/006-97.
(5) Pri nameščanju zunanje enote na višji položaj od notranje enote.
(6) Modeli 100–140PZH2E5(8) lahko v računalniških prostorih delujejo pri temperaturi do –20 °C z dolžino cevi 30 m ali manj.
* Priporočena jakost varovalke za notranjo enoto je 3 A.

Dopolnilni izdelki