Panasonic HZ25XKE-H Flagship Inverter+ - R32

Tidigare kapacitet Nästa kapacitet

Flagship: a very welcome addition to your home

The smart, new Flagship now comes with nanoe™ X technology, with the benefits of hydroxyl radicals. With advanced control options, leading-class performance and a stylish design, Flagship is designed to make your home a more comfortable, cleaner place to be.

Naturlig balans inomhus

Värmepumpen ansluter till framtiden

Specifikationer

Visa alla
Panasonic HZ25XKE-H Flagship Inverter+ - R32
2.50 kW
Maximum capacity kW 7,50kW
Reference CS-HZ25XKE-H + CU-HZ25XKE
Heating capacity (Nominal) kW 3,20
Heating capacity (Min) kW 0,85
Heating capacity (Max) kW 7,50
COP (1) W/W 5,61 
Heating capacity at -7°C (2) kW 5,00
COP at -7°C (1) W/W 2,58
Heating capacity at -15°C (2) kW 4,78
COP at -15°C (1) W/W 2,54
Heating capacity at -20°C (2) kW 4,20
COP at -20°C (1) W/W 2,40
Heating capacity at -25°C (2) kW 3,60
COP at -25°C (1) W/W 2,22
SCOP (3) 5,30 A+++
Pdesign at -10°C kW 3,00
Input power heating (Nominal) kW 0,57
Input power heating (Min) kW 0,17
Input power heating (Max) kW 2,16
Annual energy consumption heating (4) kWh/a 792
Cooling capacity (Nominal) kW 2,50
Cooling capacity (Min) kW 0,85
Cooling capacity (Max) kW 3,00
SEER (3) 8,70 A+++
Pdesign (cooling) kW 2,50
Input power cooling (Nominal) kW 0,46
Input power cooling (Min) kW 0,17
Input power cooling (Max) kW 0,67
Annual energy consumption cooling (4) kWh/a 101
Indoor unit CS-HZ25XKE-H
Indoor power source V 230
Indoor air flow (Heat) m³/min 15,7
Indoor air flow (Cool) m³/min 14,1
Moisture removal volume L/h 1,5
Indoor sound pressure (Heat -Hi) (5) dB(A) 45
Indoor sound pressure (Heat -Lo) (5) dB(A) 24
Indoor sound pressure (Heat -Q-Lo) (5) dB(A) 18
Indoor sound pressure (Cool -Hi) (5) dB(A) 44
Indoor sound pressure (Cool -Lo) (5) dB(A) 25
Indoor sound pressure (Cool -Q-Lo) (5) dB(A) 20
Indoor dimension (Height) mm 295
Indoor dimension (Width) mm 870
Indoor dimension (Depth) mm 229
Indoor net weight kg 11
nanoe X Generator Mark 2
Outdoor unit CU-HZ25XKE
Outdoor air flow (Heat) m³/min 32,7
Outdoor air flow (Cool) m³/min 32,7
Outdoor sound pressure (Heat -Hi) (5) dB(A) 47
Outdoor sound pressure (Heat -Lo) (5) dB(A) 44
Outdoor sound pressure (Cool -Hi) (5) dB(A) 46
Outdoor sound pressure (Cool -Lo) (5) dB(A) 43
Outdoor dimension (Height) (6) mm 622
Outdoor dimension (Width) (6) mm 824
Outdoor dimension (Depth) (6) mm 299
Outdoor net weight kg 34
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52)
Pipe length range m 3 ~ 20
Elevation difference (in/out) (7) m 10
Pipe length for additional gas m 7,5
Additional gas amount g/m 10
Refrigerant (R32) / CO2 Eq. kg / T 1,06 / 0,716
Operating range (Heat - Min) °C -25
Operating range (Heat - Max) °C +24
Operating range (Cool - Min) °C +16
Operating range (Cool - Max) °C +43

1) COP calculation is based in accordance to EN14511.
2) Capacity of the heat pump is tested with powerful mode with deice mode included.
3) SCOP and SEER values are Panasonic Factory official result, energy label scale from A+++ to D.
4) The annual energy consumption is calculated in accordance to EU/626/2011.
5) The sound pressure of the indoor unit shows the value measured of a position of 1m in front of the main body and 0,8m below the unit. For outdoor unit 1m in front and 1m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
6) Add 70mm for piping port.
7) When installing the outdoor unit at a higher position than the indoor unit.