K Generation 1 phase · R32

Aquarea High Performance All in One K Generation Single phase

A revolution in design, efficiency, connectivity and sustainability.
Aquarea K Generation is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance. This model is ideal for new installations and well-insulated homes.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit. The All in One model maintains its compactness with its encroachment of only 599 x 602mm, comparable to a household appliance.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.

Imate Aquarea?

Specifikacije

Pogledaj sve
K Generation 1 phase · R32 JEDNOFAZNO
3 kW 5 kW 7 kW 9 kW
Heating capacity (A +7°C, W 35°C) kW 3,20 5,00 7,00 9,00
COP (A +7°C, W 35°C) 5,33 5,10 4,86 4,55
Heating capacity (A +7°C, W 55°C) kW 3,20 5,00 7,00 8,90
COP (A +7°C, W 55°C) 2,81 3,03 2,92 2,93
Heating capacity (A +2°C, W 35°C) kW 3,20 5,00 6,85 7,00
COP (A +2°C, W 35°C) 3,64 3,57 3,43 3,40
Heating capacity (A +2°C, W 55°C) kW 3,20 5,00 6,25 6,30
COP (A +2°C, W 55°C) 2,19 2,29 2,23 2,18
Heating capacity (A -7°C, W 35°C) kW 3,30 5,00 5,75 6,25
COP (A -7°C, W 35°C) 2,80 2,79 2,95 2,84
Heating capacity (A -7°C, W 55°C) kW 3,20 5,00 5,35 5,90
COP (A -7°C, W 55°C) 1,79 1,89 1,98 1,93
Cooling capacity (A 35°C, W 7°C) kW 3,20 5,00 6,70 8,20
EER (A 35°C, W 7°C) 3,52 3,05 3,03 2,72
Cooling capacity (A 35°C, W 18°C) kW 3,20 5,00 6,70 9,00
EER (A 35°C, W 18°C) 4,71 4,90 4,72 4,18
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,07 / 3,47 5,12 / 3,63 4,90 / 3,62 4,44 / 3,41
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 200 / 136 202 / 142 193 / 142 175 / 133
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,20 / 4,20 6,00 / 4,20 5,75 / 4,07 5,75 / 4,07
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 245 / 165 237 / 165 227 / 160 227 / 160
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,00 / 2,83 4,08 / 2,95 4,18 / 2,98 4,18 / 2,98
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 157 / 110 160 / 115 164 / 116 164 / 116
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+ A++ / A+ A++ / A+ A++ / A+
Indoor sound pressure (Heat) dB(A) 28 28 28 28
Indoor sound pressure (Cool) dB(A) 28 28 28 28
Indoor dimension (Height) mm 1.642 1.642 1.642 1.642
Indoor dimension (Width) mm 599 599 599 599
Indoor dimension (Depth) mm 602 602 602 602
Indoor net weight kg 100 (3kW) / 101 (6kW) 100 (3kW) / 101 (6kW) 100 (3kW) / 101 (6kW) 100 (3kW) / 101 (6kW)
Water pipe connector Inch R 1-1/4 R 1-1/4 R 1-1/4 R 1-1/4
A class pump (Number of speeds) Variable Speed Variable Speed Variable Speed Variable Speed
A class pump (Input power Min) W 30 30 30 30
A class pump (Input power Max) W 120 120 120 120
Heating water flow (∆T=5 K. 35°C) L/min 9,2 14,3 20,1 25,8
Water volume L 185 185 185 185
Maximum water temperature °C 65 65 65 65
Material inside tank Stainless steel Stainless steel Stainless steel Stainless steel
Tapping profile according EN16147 L L L L
DHW tank ERP average climate efficiency rating (2) A+ to F A+ A+ A+ A+
DHW tank ERP warm climate efficiency rating (2) A+ to F A++ A++ A++ A++
DHW tank ERP cold climate efficiency rating (2) A+ to F A A A A
DHW tank ERP average climate η ηwh % 128 140 140 140
DHW tank ERP warm climate η ηwh % 154 160 160 160
DHW tank ERP cold climate η ηwh % 99 112 112 112
Outdoor unit WH-UDZ03KE5 WH-UDZ05KE5 WH-UDZ07KE5 WH-UDZ09KE5
Outdoor dimension (Height) mm 622 795 795 795
Outdoor dimension (Width) mm 824 875 875 875
Outdoor dimension (Depth) mm 298 320 320 320
Outdoor net weight kg 37 55 55 55
Refrigerant (R32) / CO2 Eq. kg / T 0,9 / 0,608 1,3 / 0,878 1,3 / 0,878 1,3 / 0,878
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 25 3 ~ 40 (3 ~ 50) (4) 3 ~ 40 (3 ~ 50) (4) 3 ~ 40 (3 ~ 50) (4)
Elevation difference (in/out) m 20 30 30 30
Pipe length for additional gas m 10 10 10 10
Additional gas amount g/m 20 25 25 25
Operation range - Outdoor ambient (Heat) °C -20 ~ +35 -25 ~ +35 -25 ~ +35 -25 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43
Water outlet (Heat) °C 20 ~ 60 20 ~ 60 20 ~ 60 20 ~ 60
Water outlet (Cool) °C 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20
(1) Scale from A+++ to D.
(2) Scale from A+ to F.
(3) Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7°C.
(4) Operation range down to -25°C in heating with 3 ~ 40m pipe length range, operation range down to -15°C in heating with 3 ~ 50m pipe length range.
(5) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.