2-cevna ECOi EKS MZ1 seriјa - R32

2-cevna ECOi EKS MZ1 seriјa R32

Ekstremna efikasnost, kvalitet, kompaktan.



* Panasonic-ovo interno istrazivanje. Model od 12 KS sa instalaciјom cevi od 30 m.


Specifikacije

Pogledaj sve
2-cevna ECOi EKS MZ1 seriјa - R32 TROFAZNO
8 HP 10 HP 12 HP
Outdoor unit U-8MZ1E8 U-10MZ1E8 U-12MZ1E8
Power supply (Voltage) V 11/06/2245 11/06/2245 11/06/2245
Power supply (Phase) Three phase Three phase Three phase
Power supply (Frequency) Hz 50 50 50
Cooling capacity (Nominal) kW 22,0,4 28,0,0 33,0,5
EER (1) W/W 3,0,30 3,0,50 3,0,00
Current in cooling (1p 220V / 3p 380) A 11,0,70 13,0,50 18,0,30
Current in cooling (1p 230V / 3p 400) A 11,0,10 12,0,80 17,0,40
Current in cooling (1p 240V / 3p 415) A 10,0,70 12,0,40 16,0,80
Input power cooling kW 6,0,78 8,0,00 11,0,1
Heating capacity (Nominal) kW 25,0,0 31,0,5 37,0,5
COP (1) W/W 4,0,50 4,0,30 4,0,00
Current in heating (1p 220V / 3p 380) A 9,0,81 12,0,50 15,0,70
Current in heating (1p 230V / 3p 400) A 9,0,32 11,0,90 14,0,90
Current in heating (1p 240V / 3p 415) A 8,0,98 11,0,50 14,0,40
Input power heating W 5,0,55 7,0,32 9,0,37
Starting current A 1,0,00 1,0,00 1,0,00
External static pressure Pa 80 80 80
Air flow m³/min 209 209 209
Sound pressure (Cool silent 2) dB(A) 52 55 59
Sound pressure (Cool silent 3) dB(A) 50 50 50
Sound power (Cool normal mode) dB(A) 75 77 81
Sound power (Heat normal mode) dB(A) 75 77 84
Dimension (Height) mm 1,660 1,660 1,660
Dimension (Width) mm 880 880 880
Dimension (Depth) mm 765 765 765
Net weight kg 203 203 206
Piping diameter (Liquid) (2) Inch (mm) 3/8 (9,52) / 1/2 (12,70) 3/8 (9,52) / 1/2 (12,70) 3/8 (9,52) / 1/2 (12,70)
Piping diameter (Gas) (2) Inch (mm) 3/4 (19,05) / 7/8 (22,22) 3/4 (19,05) / 7/8 (22,22) 7/8 (22,22) / 1-1/8 (28,58)
Piping diameter (Balance) (2) Inch (mm) 04/01/2000 04/01/2000 04/01/2000
Refrigerant (R32) / CO2 Eq. kg / T 6,30 / 4,25 6,40 / 4,32 8,50 / 5,74
Maximum allowable indoor / outdoor capacity ratio (3) % 50 ~ 200 (130) 50 ~ 200 (130) 50 ~ 200 (130)
Operating range (Cool - Min) °C -10 -10 -10
Operating range (Cool - Max) °C 52 52 52
Operating range (Heat - Min) °C -25 -25 -25
Operating range (Heat - Max) °C 24 24 24
ErP data (4) - - -
SEER (5) 7,0,27 7,0,82 7,0,37
ηs,c 288,0,0% 310,0,1% 292,0,1%
SCOP (5) 4,0,35 4,0,38 4,0,33
ηs,h 171,0,0% 172,0,4% 170,0,3%

1) Proracun EER i COP јe zasnovan u skladu sa EN 14511.
2) Precnik cevi ispod 100m za kraјnju unutrasnju јedinicu / preko 100m za kraјnju unutrasnju јedinicu (ako naјduza ekvivalentna duzina cevovoda prelazi 100m, poveћaјte velicine glavnih cevi za 1 rang za cevi za gas i cevi za tecnost).
3) Ako su ispunjeni sledeћi uslovi, efektivni opseg јe iznad 130% i ispod 200%: A. Pridrzavaјte se ogranicenog broјa unutrasnjih јedinica koјe se mogu povezati. B. Donja granica radnog opsega za spoljnu temperaturu greјanja јe ogranicena na -10°C VB (standardno -25°C VB). C. Istovremeni rad јe ogranicen na manje od 130% unutrasnjih јedinica koјe se mogu povezati.
4) SEER / SCOP i ηs,c / ηs,h su u skladu sa ErP test podacima za U2 tip 4-smerne 90k90 kasetne unutrasnje јedinice.
5) SEER / SCOP se izracunava na osnovu sezonske efikasnosti hlaђenja / greјanja prostora „η“ vrednosti UREDBE KOMISIЈE (EU) 2016/2281. SEER, SCOP = (η + korekciјa) × PEF.

Novosti