Low Static Pressure Hide Away Inverter • R32
Low static pressure hide away with compact indoor unit only 200m high
The duct can also be connected to KNX, Modbus interfaces for easy integration with your BMS systems. This interfaces have dry contacts (ON/OFF, error message) for easy integration.
- Duct type can be controlled by KNX and Modbus
- Eco mode for 20 % energy saving
- Extremely compact indoor units without losing static pressure (only 200 mm high)
- Weekly timer, 42 settings per week
- Easy check mode for failure detection
- Drain pump included
Otkrijte najnoviju generaciju sistema za klimatizaciju
Odlična ušteda i poboljšana dobrobit
Naši klima-uređaji obezbeđuju najviši nivo komfora uz izuzetno nisku potrošnju energije i čist vazduh bez virusa, bakterija, polena i neprijatnih mirisa.
Asortiman proizvoda koji su projektovani za Vas
Od manjih rešenja 1X1 do kompletnijih rešenja 5X1, nema veze koje su Vam potrebe. Panasonic može da Vam ponudi najbolja rešenja za klimatizaciju Vašeg doma.
Udoban dom tokom cele godine
Naši klima-uređaji Vam pružaju najprijatniju temperaturu tokom godine, grejanje zimi, hlađenje leti i čist vazduh tokom čitave godine.
Odlična ušteda i poboljšana dobrobit
Naši klima-uređaji obezbeđuju najviši nivo komfora uz izuzetno nisku potrošnju energije i čist vazduh bez virusa, bakterija, polena i neprijatnih mirisa.
Asortiman proizvoda koji su projektovani za Vas
Od manjih rešenja 1X1 do kompletnijih rešenja 5X1, nema veze koje su Vam potrebe. Panasonic može da Vam ponudi najbolja rešenja za klimatizaciju Vašeg doma.
Udoban dom tokom cele godine
Naši klima-uređaji Vam pružaju najprijatniju temperaturu tokom godine, grejanje zimi, hlađenje leti i čist vazduh tokom čitave godine.
Klimatizacija se povezuje sa budućnošću.
Specifikacije
Low Static Pressure Hide Away Inverter • R32 | |||
---|---|---|---|
3.5 kW | |||
Kit | KIT-Z35-UD3 | ||
Cooling capacity (Nominal) | kW | 3,50 | |
Cooling capacity (Min) | kW | 0,85 | |
Cooling capacity (Max) | kW | 4,00 | |
EER (Nominal) (1) | W/W | 3,85 | |
EER (Min) (1) | W/W | 3,54 | |
EER (Max) (1) | W/W | 3,36 | |
SEER (2) | 5,80 A+ | ||
Pdesign (cooling) | kW | 3,50 | |
Input power cooling (Nominal) | kW | 0,91 | |
Input power cooling (Min) | kW | 0,24 | |
Input power cooling (Max) | kW | 1,19 | |
Annual energy consumption cooling (3) | kWh/a | 211,00 | |
Heating capacity (Nominal) | kW | 4,20 | |
Heating capacity (Min) | kW | 0,85 | |
Heating capacity (Max) | kW | 5,10 | |
Heating capacity at -7°C | kW | 3,00 | |
COP (Nominal) (1) | W/W | 3,82 | |
COP (Min) (1) | W/W | 3,70 | |
COP (Max) (1) | W/W | 3,59 | |
SCOP (2) | 4,10 A+ | ||
Pdesign at -10°C | kW | 2,80 | |
Input power heating (Nominal) | kW | 1,10 | |
Input power heating (Min) | kW | 0,23 | |
Input power heating (Max) | kW | 1,42 | |
Annual energy consumption heating (3) | kWh/a | 956 | |
Indoor unit | CS-Z35UD3EAW | ||
External static pressure (Min) (7) | Pa | 15 | |
External static pressure (Max) (7) | Pa | 45 | |
Indoor power source | V | 230 | |
Indoor air flow (Cool) | m³/min | 11,2 | |
Indoor air flow (Heat) | m³/min | 11,2 | |
Moisture removal volume | L/h | 2,0 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 33 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 33 | |
Indoor sound pressure (Cool -Lo) (4) | dB(A) | 27 | |
Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 24 | |
Indoor sound pressure (Heat -Hi) (4) | dB(A) | 35 | |
Indoor sound pressure (Heat -Lo) (4) | dB(A) | 27 | |
Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 24 | |
Indoor dimension (Height) | mm | 200 | |
Indoor dimension (Width) | mm | 750 | |
Indoor dimension (Depth) | mm | 640 | |
Indoor net weight | kg | 19 | |
Outdoor unit | CU-Z35UBEA | ||
Outdoor power source | V | 230 | |
Outdoor recommended fuse | A | 16 | |
Outdoor connection indoor / outdoor | mm² | 4 x 1,5 ~ 2,5 | |
Outdoor air flow (Cool) | m³/min | 34,3 | |
Outdoor air flow (Heat) | m³/min | 33,5 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 48 | |
Outdoor dimension (Height) (5) | mm | 619 | |
Outdoor dimension (Width) (5) | mm | 824 | |
Outdoor dimension (Depth) (5) | mm | 299 | |
Outdoor net weight | kg | 35 | |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
Pipe diameter (Gas) | Inch (mm) | 3/8 (9,52) | |
Pipe length range | m | 3 ~ 20 | |
Elevation difference (in/out) (6) | m | 15 | |
Pipe length for additional gas | m | 7,5 | |
Additional gas amount | g/m | 10 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 0,93 / 0,628 | |
Operating range (Cool - Min) | °C | -10 | |
Operating range (Cool - Min) | °C | -10 | |
Operating range (Cool - Max) | °C | +43 | |
Operating range (Heat - Min) | °C | -15 | |
Operating range (Heat - Max) | °C | +24 |
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position of 1,5m below the unit with 1m duct on the suction side and 2m duct on the discharge side. For outdoor unit 1m in front and 1m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612.
(5) Add 100mm for indoor unit or 70mm for outdoor unit for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.
(7) The specification listed on the table indicates values under the condition of 25Pa (2,5mmAq) which are applied for factory default setting. Change switch on PCB from Hi to S-Hi to have more than 6,0mmAq.