UZ super-compact • R32
Wall-mounted UZ super-compact Inverter.
UZ is a compact and quiet wall split series with high standards specs.
- Compact design with 779 mm
- Dust Collection Filter
- Very Quiet
- Aerowings to control air draft direction
- High energy savings
- Cooling even at -10 °C
- Optional internet and voice control
Otkrijte najnoviju generaciju sistema za klimatizaciju
Odlična ušteda i poboljšana dobrobit
Naši klima-uređaji obezbeđuju najviši nivo komfora uz izuzetno nisku potrošnju energije i čist vazduh bez virusa, bakterija, polena i neprijatnih mirisa.
Asortiman proizvoda koji su projektovani za Vas
Od manjih rešenja 1X1 do kompletnijih rešenja 5X1, nema veze koje su Vam potrebe. Panasonic može da Vam ponudi najbolja rešenja za klimatizaciju Vašeg doma.
Udoban dom tokom cele godine
Naši klima-uređaji Vam pružaju najprijatniju temperaturu tokom godine, grejanje zimi, hlađenje leti i čist vazduh tokom čitave godine.
Odlična ušteda i poboljšana dobrobit
Naši klima-uređaji obezbeđuju najviši nivo komfora uz izuzetno nisku potrošnju energije i čist vazduh bez virusa, bakterija, polena i neprijatnih mirisa.
Asortiman proizvoda koji su projektovani za Vas
Od manjih rešenja 1X1 do kompletnijih rešenja 5X1, nema veze koje su Vam potrebe. Panasonic može da Vam ponudi najbolja rešenja za klimatizaciju Vašeg doma.
Udoban dom tokom cele godine
Naši klima-uređaji Vam pružaju najprijatniju temperaturu tokom godine, grejanje zimi, hlađenje leti i čist vazduh tokom čitave godine.
Klimatizacija se povezuje sa budućnošću.
Specifikacije
UZ super-compact • R32 | |||
---|---|---|---|
5.00 kW | |||
Kit | KIT-UZ50-ZKE | ||
Cooling capacity (Nominal) | kW | 5,00 | |
Cooling capacity (Min) | kW | 0,98 | |
Cooling capacity (Max) | kW | 5,40 | |
EER (Nominal) (1) | W/W | 3,03 | |
EER (Min) (1) | W/W | 3,92 | |
EER (Max) (1) | W/W | 2,89 | |
SEER (2) | 6,50 A++ | ||
Pdesign (cooling) | kW | 5 | |
Input power cooling (Nominal) | kW | 1,65 | |
Input power cooling (Min) | kW | 0,25 | |
Input power cooling (Max) | kW | 1,87 | |
Annual energy consumption cooling (3) | kWh/a | 269 | |
Heating capacity (Nominal) | kW | 5,40 | |
Heating capacity (Min) | kW | 0,98 | |
Heating capacity (Max) | kW | 7,40 | |
Heating capacity at -7°C | kW | 4,52 | |
COP (Nominal) (1) | W/W | 3,42 | |
COP (Min) (1) | W/W | 4,67 | |
COP (Max) (1) | W/W | 3,08 | |
SCOP (2) | 4,10 A+ | ||
Pdesign at -10°C | kW | 4 | |
Input power heating (Nominal) | kW | 1,58 | |
Input power heating (Min) | kW | 0,21 | |
Input power heating (Max) | kW | 2,40 | |
Annual energy consumption heating (3) | kWh/a | 1.366 | |
Indoor unit | CS-UZ50ZKE | ||
Indoor power source | V | 230 | |
Indoor recommended fuse | A | 16 | |
Indoor connection indoor / outdoor | mm² | 4 x 2,5 | |
Indoor air flow (Cool) | m³/min | 12,5 | |
Indoor air flow (Heat) | m³/min | 13,2 | |
Moisture removal volume | L/h | 2,8 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 44 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 44 | |
Indoor sound pressure (Cool -Lo) (4) | dB(A) | 37 | |
Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 34 | |
Indoor sound pressure (Heat -Hi) (4) | dB(A) | 44 | |
Indoor sound pressure (Heat -Lo) (4) | dB(A) | 37 | |
Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 34 | |
Indoor dimension (Height) | mm | 290 | |
Indoor dimension (Width) | mm | 779 | |
Indoor dimension (Depth) | mm | 209 | |
Indoor net weight | kg | 8 | |
Outdoor unit | CU-UZ50ZKE | ||
Outdoor air flow (Cool) | m³/min | 32,7 | |
Outdoor air flow (Heat) | m³/min | 32,7 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 49 | |
Outdoor dimension (Height) (5) | mm | 619 | |
Outdoor dimension (Width) (5) | mm | 824 | |
Outdoor dimension (Depth) (5) | mm | 299 | |
Outdoor net weight | kg | 35 | |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | |
Pipe length range | m | 3 ~ 15 | |
Elevation difference (in/out) (6) | m | 15 | |
Pipe length for additional gas | m | 10 | |
Additional gas amount | g/m | 15 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,07 / 0,72 | |
Operating range (Cool - Min) | °C | -10 | |
Operating range (Cool - Min) | °C | -10 | |
Operating range (Cool - Max) | °C | +43 | |
Operating range (Heat - Min) | °C | -15 | |
Operating range (Heat - Max) | °C | +24 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.