K Generation 1 phase. 2 zones · R32
Aquarea High Performance All in One K Generation Single phase
A revolution in design, efficiency, connectivity and sustainability.Aquarea K Generation is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance. This model is ideal for new installations and well-insulated homes.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit. The All in One model maintains its compactness with its encroachment of only 599 x 602mm, comparable to a household appliance.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.
- COP up to 5,33
- A+++ in heating at 35°C and A+ in DHW
- “A” water pump with variable speed
- Stainless steel DHW tank with U-Vacua™ insulation panel
- DHW COP up to 3,50
- Built-in magnetic water filter
- 2 zone control
- Operation without backup heating at -25°C
- 60°C hot water even at -10°C outside temperature
- Optimised user interface and improved features
- Optional Aquarea Smart and Service Cloud and integration into BMS projects
Aquarea Service Cloud Kontrola za danas i za budućnost
Imate Aquarea?
Specifikacije
K Generation 1 phase. 2 zones · R32 | |||
---|---|---|---|
5 kW | |||
Kit | KIT-ADC05K3E5B | ||
Heating capacity (A +7°C, W 35°C) | kW | 5,00 | |
COP (A +7°C, W 35°C) | 5,10 | ||
Heating capacity (A +7°C, W 55°C) | kW | 5,00 | |
COP (A +7°C, W 55°C) | 3,03 | ||
Heating capacity (A +2°C, W 35°C) | kW | 5,00 | |
COP (A +2°C, W 35°C) | 3,57 | ||
Heating capacity (A +2°C, W 55°C) | kW | 5,00 | |
COP (A +2°C, W 55°C) | 2,29 | ||
Heating capacity (A -7°C, W 35°C) | kW | 5,00 | |
COP (A -7°C, W 35°C) | 2,79 | ||
Heating capacity (A -7°C, W 55°C) | kW | 5,00 | |
COP (A -7°C, W 55°C) | 1,89 | ||
Cooling capacity (A 35°C, W 7°C) | kW | 5,00 | |
EER (A 35°C, W 7°C) | 3,05 | ||
Cooling capacity (A 35°C, W 18°C) | kW | 5,00 | |
EER (A 35°C, W 18°C) | 4,90 | ||
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 5,12 / 3,63 | |
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 202 / 142 | |
Heating average climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | |
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 6,00 / 4,20 | |
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 237 / 165 | |
Heating warm climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | |
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,08 / 2,95 | |
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 160 / 115 | |
Heating cold climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A++ / A+ | |
Indoor unit | WH-ADC0309K3E5B | ||
Indoor sound pressure (Heat) | dB(A) | 28 | |
Indoor sound pressure (Cool) | dB(A) | 28 | |
Indoor dimension (Height) | mm | 1.642 | |
Indoor dimension (Width) | mm | 599 | |
Indoor dimension (Depth) | mm | 602 | |
Indoor net weight | kg | 100 (3kW) / 101 (6kW) | |
Water pipe connector | Inch | R 1-1/4 | |
A class pump (Number of speeds) | Variable Speed | ||
A class pump (Input power Min) | W | 30 | |
A class pump (Input power Max) | W | 120 | |
Heating water flow (∆T=5 K. 35°C) | L/min | 14,3 | |
Water volume | L | 185 | |
Maximum water temperature | °C | 65 | |
Material inside tank | Stainless steel | ||
Tapping profile according EN16147 | L | ||
DHW tank ERP average climate efficiency rating (2) | A+ to F | A+ | |
DHW tank ERP warm climate efficiency rating (2) | A+ to F | A++ | |
DHW tank ERP cold climate efficiency rating (2) | A+ to F | A | |
DHW tank ERP average climate η | ηwh % | 140 | |
DHW tank ERP warm climate η | ηwh % | 160 | |
DHW tank ERP cold climate η | ηwh % | 112 | |
Outdoor unit | WH-UDZ05KE5 | ||
Outdoor dimension (Height) | mm | 795 | |
Outdoor dimension (Width) | mm | 875 | |
Outdoor dimension (Depth) | mm | 320 | |
Outdoor net weight | kg | 55 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,3 / 0,878 | |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
Pipe diameter (Gas) | Inch (mm) | 5/8 (15,88) | |
Pipe length range | m | 3 ~ 40 (3 ~ 50) (4) | |
Elevation difference (in/out) | m | 30 | |
Pipe length for additional gas | m | 10 | |
Additional gas amount | g/m | 25 | |
Operation range - Outdoor ambient (Heat) | °C | -25 ~ +35 | |
Operation range - Outdoor ambient (Cool) | °C | +10 ~ +43 | |
Water outlet (Heat) | °C | 20 ~ 60 | |
Water outlet (Cool) | °C | 5 ~ 20 |
(2) Scale from A+ to F.
(3) Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7°C.
(4) Operation range down to -25°C in heating with 3 ~ 40m pipe length range, operation range down to -15°C in heating with 3 ~ 50m pipe length range.
(5) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.