Specifikacije

Pogledaj sve
PACi NX serija Elite adaptivna kanalska jedinica s inverterom + - R32
7.1 kW
Kit KIT-71PF3ZH45
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 6,8
Cooling capacity (Min) kW 2,2
Cooling capacity (Max) kW 7,8
EER (Nominal) (1) W/W 3,74
EER (Min) (1) W/W 2,41
EER (Max) (1) W/W 5,64
SEER/ηsc (2) % 7,1 A++
Pdesign (cooling) kW 6,8
Input power cooling (Nominal) kW 1,82
Input power cooling (Min) kW 0,39
Input power cooling (Max) kW 3,24
Annual energy consumption cooling (3) kWh/a 332
Heating capacity (Nominal) kW 7,5
Heating capacity (Min) kW 2,0
Heating capacity (Max) kW 9,0
COP (Nominal) (1) W/W 4,03
COP (Min) (1) W/W 3,16
COP (Max) (1) W/W 5,41
SCOP/ηsc (2) % 4,7 A++
Pdesign at -10°C kW 4,7
Input power heating (Nominal) kW 1,86
Input power heating (Min) kW 0,37
Input power heating (Max) kW 2,85
Annual energy consumption heating (3) kWh/a 1.393
Indoor unit S-6071PF3E
External static pressure (Nominal) (4) Pa 30
External static pressure (Min) (4) Pa 10
External static pressure (Max) (4) Pa 150
Moisture removal volume L/h 21,0
Indoor air flow (Hi) m³/min 19,0
Indoor air flow (Med) m³/min 15,0
Indoor air flow (Lo) m³/min 2,7
Indoor sound pressure (Hi) (5) dB(A) 30
Indoor sound pressure (Med) (5) dB(A) 26
Indoor sound pressure (Lo) (5) dB(A) 23
Indoor sound power (Hi) dB(A) 53
Indoor sound power (Med) dB(A) 49
Indoor sound power (Lo) dB(A) 46
Indoor dimension (Height) mm 250
Indoor dimension (Width) mm 1.000
Indoor dimension (Depth) mm 730
Indoor net weight kg 30
nanoe X Generator Mark 2
Outdoor unit U-71PZH4E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 9,20
Current in cooling (1p 230V / 3p 400) A 8,80
Current in cooling (1p 240V / 3p 415) A 8,45
Current in heating (1p 220V / 3p 380) A 9,40
Current in heating (1p 230V / 3p 400) A 9,00
Current in heating (1p 240V / 3p 415) A 8,60
Outdoor air flow (Cool) m³/min 62,0
Outdoor air flow (Heat) m³/min 66,0
Outdoor sound pressure (Cool -Hi) dB(A) 48
Outdoor sound pressure (Heat -Hi) dB(A) 50
Outdoor sound power (Cool -Hi) dB(A) 65
Outdoor sound power (Heat -Hi) dB(A) 67
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 66
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 60
Elevation difference (in/out) (8) m 15 / 30
Pipe length for additional gas m 30
Additional gas amount g/m 30
Refrigerant (R32) / CO2 Eq. kg / T 1,95 / 1,32
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C +52
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

1) Izračunavanje vrednosti EER i COP je zasnovano na standardu EN14511.
2) Za modele ispod 12 kW, SEER i SCOP se proračunavaju na osnovu vrednosti EU/626/2011. Za modele iznad 12 kW, ηsc/ηsh vrednosti se izračunavaju na osnovu standarda EN 14825.
3) Fabričko podešavanje.
4) Srednje podešavanja spoljašnjeg statičkog pritiska u fabrici.
5) Zvučni pritisak jedinica prikazuje vrednost izmerenu za položaj 1,5 m ispod jedinice. Zvučni pritisak se meri u skladu sa specifikacijom Eurovent 6/C/006-97.
6) Povežite priključnu cev za tečnost (Ø6,35 – Ø9,52) na strani sa cevima za tečnost kod unutrašnje jedinice
7) Povežite priključnu cev za gas (Ø12,70 – Ø15,88) na strani sa cevima za gas kod unutrašnje jedinice. 8) Spoljašnja jedinica postavljena je na nižem položaju / spoljašnja jedinica postavljena je na višem položaju.
9) Dužina cevi do 30 m.
* Preporučena snaga osigurača za unutrašnju ugradnju iznosi 3 A.

** Navedene vrednosti važe u slučaju standardne instalacije (horizontalna instalacija u plafonu, ulaz vazduha sa zadnje strane) i kada je nanoe™ X ISKLJUČEN.

Dodatni proizvodi