Aquarea High Performance All in One H Generation 3 Phase • R410A

Aquarea, an innovative new low-energy system based on Air to Water heat pump technology


Aquarea warms your home effectively and efficiently, even with extreme outdoor temperatures. Aquarea can also cool space in summer and bring hot water all year round.
Aquarea High Performance is the range for new installations and low consumption homes. Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
Aquarea All in One: This range intelligently integrates the best Hydrokit technology with a premium quality stainless steel tank, which is maintenance-free.

Pompa de căldură transformă energia din exterior în căldură în interior

Specificații

Vizualizare toate
Aquarea High Performance All in One H Generation 3 Phase • R410A THREE PHASE (Power to indoor)
9 kW 12 kW 16 kW
Kit KIT-ADC09HE8 KIT-ADC12HE8 KIT-ADC16HE8
Heating capacity (A +7°C, W 35°C) kW 9,00 12,00 16,00
COP (A +7°C, W 35°C) 4,84 4,74 4,28
Heating capacity (A +7°C, W 55°C) kW 9,00 12,00 14,50
COP (A +7°C, W 55°C) 2,94 2,88 2,68
Heating capacity (A +2°C, W 35°C) kW 9,00 11,40 13,00
COP (A +2°C, W 35°C) 3,59 3,44 3,28
Heating capacity (A +2°C, W 55°C) kW 8,80 9,10 9,80
COP (A +2°C, W 55°C) 2,23 2,20 2,17
Heating capacity (A -7°C, W 35°C) kW 9,00 10,00 11,40
COP (A -7°C, W 35°C) 2,85 2,73 2,57
Heating capacity (A -7°C, W 55°C) kW 7,90 8,20 9,00
COP (A -7°C, W 55°C) 2,05 1,92 1,82
Cooling capacity (A 35°C, W 7°C) kW 7,00 10,00 12,20
EER (A 35°C, W 7°C) 3,17 2,85 2,56
Cooling capacity (A 35°C, W 18°C) kW 7,00 10,00 12,20
EER (A 35°C, W 18°C) 4,61 4,17 4,12
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 190 / 133 190 / 134 190 / 130
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,83 / 3,40 4,83 / 3,43 4,83 / 3,33
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 245 / 159 245 / 159 245 / 169
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,20 / 4,05 6,20 / 4,05 6,20 / 4,30
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 168 / 121 168 / 121 168 / 121
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,28 / 3,10 4,28 / 3,10 4,28 / 3,10
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+ A++ / A+ A++ / A+
Indoor unit WH-ADC0916H9E8 WH-ADC0916H9E8 WH-ADC0916H9E8
Indoor sound pressure (Heat) dB(A) 33 33 33
Indoor sound pressure (Cool) dB(A) 33 33 33
Indoor dimension (Height) mm 1800 1800 1800
Indoor dimension (Width) mm 598 598 598
Indoor dimension (Depth) mm 717 717 717
Indoor net weight kg 126 126 126
Water pipe connector Inch R 1¼ R 1¼ R 1¼
A class pump (Number of speeds) Variable Speed Variable Speed Variable Speed
A class pump (Input power Min) W 36 36 36
A class pump (Input power Max) W 152 152 152
Heating water flow (∆T=5 K. 35°C) L/min 25,80 34,40 45,90
Capacity of integrated electric heater kW 9,00 9,00 9,00
Indoor recommended fuse A 16 / 16 16 / 16 16 / 16
Recommended cable size, supply 1 mm² 5 x 1,5 5 x 1,5 5 x 1,5
Recommended cable size, supply 2 mm² 5 x 1,5 5 x 1,5 5 x 1,5
Water volume L 185 185 185
Maximum water temperature °C 65 65 65
Material inside tank Stainless steel Stainless steel Stainless steel
Tapping profile according EN16147 L L L
DHW tank ERP average climate efficiency rating (2) A+ to F A A A
DHW tank ERP warm climate efficiency rating (2) A+ to F A A A
DHW tank ERP cold climate efficiency rating (2) A+ to F A A B
DHW tank ERP average climate η ηwh % 95 95 91
DHW tank ERP average climate SCOP 2,38 2,38 2,28
DHW tank ERP warm climate η ηwh % 110 110 107
DHW tank ERP warm climate SCOP 2,75 2,75 2,68
DHW tank ERP cold climate η ηwh % 75 75 72
DHW tank ERP cold climate SCOP 1,88 1,80 1,88
Outdoor unit WH-UD09HE8 WH-UD12HE8 WH-UD16HE8
Outdoor sound power part load (Heat) (3) dB(A) 65 65 65
Outdoor sound power full load (Heat) dB(A) 68 69 72
Outdoor sound power full load (Cool) dB(A) 67 68 72
Outdoor dimension (Height) mm 1340 1340 1340
Outdoor dimension (Width) mm 900 900 900
Outdoor dimension (Depth) mm 320 320 320
Outdoor net weight kg 107 107 107
Refrigerant (R410A) / CO2 Eq. kg / T 2,55 / 5,324 2,55 / 5,324 2,55 / 5,324
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 30 3 ~ 30 3 ~ 30
Elevation difference (in/out) m 20 20 20
Pipe length for additional gas m 10 10 10
Additional gas amount g/m 50 50 50
Operation range (Outdoor ambient) °C -20 ~ +35 -20 ~ +35 -20 ~ +35
Water outlet (Heat) °C 20 ~ 55 20 ~ 55 20 ~ 55
Water outlet (Cool) °C 5 ~ 20 5 ~ 20 5 ~ 20

(1) Scale from A+++ to D.
(2) Scale from A+ to F.
(3) Sound power in accordance to 8112013,81312013 and EN12102-1:2017 at +7°C.
EER and COP calculation is based in accordance to EN14511.
This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.

Produse complementare