PACi Standard adaptive ducted unit - PF3 - R32

Newly designed adaptive ducted unit - PF3 for R32 PACi

2 installation possibilities (horizontal / vertical) with high external static pressure 150Pa allows flexible installation.

Echilibrul naturii, acum în casa dumneavoastră

Specificații

Vizualizare toate
PACi Standard adaptive ducted unit - PF3 - R32
12.5 kW
Kit KIT-125PF3Z25
Remote controller CZ-RTC6
Cooling capacity (Nominal) kW 12,1
Cooling capacity (Min) kW 3,2
Cooling capacity (Max) kW 13,5
EER (Nominal) (1) W/W 3,40
EER (Min) (1) W/W 5,93
EER (Max) (1) W/W 2,76
SEER/ηsc (2) % 257,5
Pdesign (cooling) kW 12,1
Input power cooling (Nominal) kW 3,56
Input power cooling (Min) kW 0,54
Input power cooling (Max) kW 4,90
Annual energy consumption cooling (3) kWh/a
Heating capacity (Nominal) kW 12,1
Heating capacity (Min) kW 3,3
Heating capacity (Max) kW 15,0
COP (Nominal) (1) W/W 3,56
COP (Min) (1) W/W 6,11
COP (Max) (1) W/W 3,16
SCOP/ηsc (2) % 144,2
Pdesign at -10°C kW 9,3
Input power heating (Nominal) kW 3,40
Input power heating (Min) kW 0,54
Input power heating (Max) kW 4,74
Annual energy consumption heating (3) kWh/a
Indoor unit S-1014PF3E
External static pressure (Nominal) (4) Pa 50
External static pressure (Min) (4) Pa 10
External static pressure (Max) (4) Pa 150
Moisture removal volume L/h 4,1
Indoor air flow (Hi) m³/min 34,0
Indoor air flow (Med) m³/min 29,0
Indoor air flow (Lo) m³/min 23,0
Indoor sound pressure (Hi) (5) dB(A) 35
Indoor sound pressure (Med) (5) dB(A) 31
Indoor sound pressure (Lo) (5) dB(A) 27
Indoor sound power (Hi) dB(A) 58
Indoor sound power (Med) dB(A) 54
Indoor sound power (Lo) dB(A) 50
Indoor dimension (Height) mm 250
Indoor dimension (Width) mm 1400
Indoor dimension (Depth) mm 730
Indoor net weight kg 39
nanoe X Generator Mark 2
Outdoor unit U-125PZ2E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 16,40
Current in cooling (1p 230V / 3p 400) A 15,70
Current in cooling (1p 240V / 3p 415) A 15,10
Current in heating (1p 220V / 3p 380) A 15,70
Current in heating (1p 230V / 3p 400) A 15,00
Current in heating (1p 240V / 3p 415) A 14,40
Outdoor air flow (Cool) m³/min 86
Outdoor air flow (Heat) m³/min 78
Outdoor sound pressure (Cool -Hi) dB(A) 55
Outdoor sound pressure (Heat -Hi) dB(A) 55
Outdoor sound power (Cool -Hi) dB(A) 73
Outdoor sound power (Heat -Hi) dB(A) 73
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 94
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 50
Elevation difference (in/out) (6) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 2,98 / 2,0115
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηsc / ηsh values is calculated based on EN 14825.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Medium External static pressure setting from factory.
(5) The sound pressure of the units shows the value measured of the position 1,5m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3A.
** Above values are in the case of standard installation(horizontal installation in the celling, rear side air intake) and nanoe™ X OFF.