Série PACi NX Standard Consola de Teto Inverter+ · R32

As unidades montadas no teto proporcionam uma distribuição de ar grande e ampla, o que é bom para divisões grandes

A altura e a profundidade de todas as capacidades são as mesmas para uma aparência unificada em instalações mistas.

A próxima geração de ar condicionado comercial

Especificações

Ver tudo
Série PACi NX Standard Consola de Teto Inverter+ · R32 MONOFÁSICO TRIFÁSICO
3.6 kW 5.0 kW 6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 10.0 kW 12.5 kW 14.0 kW
Kit KIT-36PT3Z5 KIT-50PT3Z5 KIT-60PT3Z5 KIT-71PT3Z5 KIT-100PT3Z5 KIT-125PT3Z5 KIT-140PT3Z5 KIT-100PT3Z8 KIT-125PT3Z8 KIT-140PT3Z8
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 3,5 5,0 6,0 6,8 10,0 12,5 14,0 10,0 12,5 14,0
Cooling capacity (Min) kW 1,5 1,5 2,0 2,6 3,0 3,2 3,3 3,0 3,2 3,3
Cooling capacity (Max) kW 4,0 5,2 7,1 7,7 11,5 13,5 15,0 11,5 13,5 15,0
EER (Nominal) (1) W/W 4,14 3,03 3,59 3,24 3,64 3,32 2,98 3,64 3,32 2,98
SEER/ηsc (2) % 7,2 A++ 6,7 A++ 7,3 A++ 5,9 A+ 6,6 A++ 241,7 % 228,8 % 6,5 A++ 240,9 % 228,1 %
Pdesign (cooling) kW 3,5 5,0 6,0 6,8 10,0 12,5 14,0 10,0 12,5 14,0
Input power cooling (Nominal) kW 0,85 1,65 1,67 2,10 2,75 3,76 4,70 2,75 3,76 4,70
Annual energy consumption cooling (3) kWh/a 171 262 288 404 531 537
Heating capacity (Nominal) kW 3,5 5,0 6,0 6,8 10,0 12,5 14,0 10,0 12,5 14,0
Heating capacity (Min) kW 1,5 1,5 1,8 2,1 3,0 3,3 3,4 3,0 3,3 3,4
Heating capacity (Max) kW 4,6 6,4 7,0 8,1 14,0 15,0 16,0 14,0 15,0 16,0
COP (Nominal) (1) W/W 4,61 3,73 4,11 4,20 4,24 3,89 3,70 4,24 3,89 3,70
SCOP/ηsc (2) % 4,4 A+ 4,1 A+ 4,6 A++ 4,3 A+ 4,2 A+ 147,4 % 145,3 % 4,2 A+ 147,4 % 145,3 %
Pdesign at -10°C kW 2,8 4,0 4,6 4,7 10,0 12,5 13,6 10,0 12,5 13,6
Input power heating (Nominal) kW 0,76 1,34 1,46 1,62 2,36 3,21 3,78 2,36 3,21 3,78
Annual energy consumption heating (3) kWh/a 891 1.365 1.399 1.529 3.331 3.331
Indoor unit S-3650PT3E S-3650PT3E S-6071PT3E S-6071PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E
Indoor air flow (Hi) m³/min 14,0 15,0 20,0 21,0 30,0 34,0 35,0 30,0 34,0 35,0
Indoor air flow (Med) m³/min 12,0 12,5 17,0 18,0 25,0 28,0 29,0 25,0 28,0 29,0
Indoor air flow (Lo) m³/min 10,5 10,5 14,5 15,5 23,0 24,0 25,0 23,0 24,0 25,0
Moisture removal volume L/h 0,8 2,0 2,1 2,7 4,1 5,7 6,9 4,1 5,7 6,9
Indoor sound pressure (Med) (4) dB(A) 32 33 34 35 37 40 41 37 40 41
Indoor sound pressure (Lo) (4) dB(A) 28 28 29 30 34 35 36 34 35 36
Indoor sound power (Hi) dB(A) 54 55 56 57 60 64 65 60 64 65
Indoor sound power (Med) dB(A) 50 51 52 53 55 58 59 55 58 59
Indoor sound power (Lo) dB(A) 46 46 47 48 52 53 54 52 53 54
Indoor dimension (Height) mm 235 235 235 235 235 235 235 235 235 235
Indoor dimension (Width) mm 960 960 1.275 1.275 1.590 1.590 1.590 1.590 1.590 1.590
Indoor dimension (Depth) mm 690 690 690 690 690 690 690 690 690 690
Indoor net weight kg 26 26 34 34 40 40 40 40 40 40
nanoe X Generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Outdoor unit U-36PZ3E5 U-50PZ3E5 U-60PZ3E5A U-71PZ3E5A U-100PZ3E5 U-125PZ3E5 U-140PZ3E5 U-100PZ3E8 U-125PZ3E8 U-140PZ3E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 3,90 7,65 7,75 9,75 13,70 18,20 22,70 4,60 6,10 7,60
Current in cooling (1p 230V / 3p 400) A 3,75 7,30 7,40 9,30 13,10 17,40 21,70 4,35 5,75 7,20
Current in cooling (1p 240V / 3p 415) A 3,60 7,00 7,10 8,95 12,60 16,70 20,80 4,20 5,55 6,95
Current in heating (1p 220V / 3p 380) A 3,55 6,30 6,75 7,50 11,80 15,50 18,30 3,95 5,20 6,10
Current in heating (1p 230V / 3p 400) A 3,40 6,00 6,50 7,20 11,30 14,80 17,50 3,75 4,95 5,80
Current in heating (1p 240V / 3p 415) A 3,25  5,75 6,20 6,90 10,80 14,20 16,80 3,60 4,75 5,60
Outdoor air flow (Cool) m³/min 33,6 32,7 42,6 44,7 73,0 82,0 84,0 73,0 82,0 84,0
Outdoor air flow (Heat) m³/min 34,0 31,9 41,5 45,9 73,0 80,0 82,0 73,0 80,0 82,0
Outdoor sound pressure (Cool -Hi) dB(A) 46 46 47 48 52 55 56 52 55 56
Outdoor sound pressure (Heat -Hi) dB(A) 47 46 48 49 52 55 56 52 55 56
Outdoor sound power (Cool -Hi) dB(A) 64 64 64 66 70 73 74 70 73 74
Outdoor sound power (Heat -Hi) dB(A) 66 64 65 68 70 73 74 70 73 74
Outdoor dimension (Height) mm 619 619 695 695 996 996 996 996 996 996
Outdoor dimension (Width) mm 824 824 875 875 980 980 980 980 980 980
Outdoor dimension (Depth) mm 299 299 320 320 370 370 370 370 370 370
Outdoor net weight kg 32 35 42 50 83 87 87 83 87 87
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) (5) 1/4 (6,35) (5) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70) (6) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 15 3 ~ 20 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50
Elevation difference (in/out) (7) m 15 / 15 (8) 15 / 15 (8) 15 / 30 (8) 20 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8)
Pipe length for additional gas m 7,5 7,5 30 30 30 30 30 30 30 30
Additional gas amount g/m 10 15 15 17 45 45 45 45 45 45
Refrigerant (R32) / CO2 Eq. kg / T 0,87 / 0,59 1,14 / 0,77 1,15 / 0,78 1,32 / 0,89 2,40 / 1,62 2,80 / 1,89 2,80 / 1,89 2,40 / 1,62 2,80 / 1,89 2,80 / 1,89
Operating range (Cool - Min) °C -10 -10 -10 -10 -10 -10 -10 -10 -10 -10
Operating range (Cool - Max) °C +43 +43 +43 +43 +43 +43 +43 +43 +43 +43
Operating range (Heat - Min) °C -15 -15 -15 -15 -15 -15 -15 -15 -15 -15
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24 +24 +24 +24

1) O cálculo do EER e do COP é efectuado de acordo com a norma EN14511.
2) Para modelos inferiores a 12 kW, o SEER e o SCOP são calculados com base nos valores da norma EU/626/2011. Para modelos superiores a 12 kW, os valores ηsc / ηsh são calculados com base na norma EN 14825.
3) Definição de fábrica.
4) A pressão sonora das unidades apresenta o valor medido na posição 1 m à frente do corpo principal e 1 m abaixo da unidade. A pressão sonora é medida de acordo com a especificação Eurovent 6/C/006-97.
5) Ligue o tubo de encaixe de líquido (Ø6,35-Ø9,52) à unidade interior do lado da tubagem de líquido.
6) Ligue o tubo de tomada de gás (Ø12,70-Ø15,88) à unidade interior do lado da tubagem de gás.
7) Quando instalar a unidade de exterior numa posição mais elevada do que a unidade de interior.
8) Unidade exterior situada mais abaixo / unidade exterior situada mais acima.
* Fusível recomendado para a unidade interior 3A.
** Os valores acima indicados são para o caso de nanoe™ X OFF.