Série PACi NX Standard Cassete 4 vias 60x60 Inverter+ · R32 | MONOFÁSICO | |||||
---|---|---|---|---|---|---|
2.5 kW | 3.6 kW | 5.0 kW | 6.0 kW | |||
Kit | KIT-25PY3Z5 | KIT-36PY3Z5 | KIT-50PY3Z5 | KIT-60PY3Z5 | ||
Remote controller | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | ||
EER (Min) (1) | W/W | 3,55 | 3,57 | 3,03 | 2,77 | |
EER (Max) (1) | W/W | 5,88 | 5,88 | 6,25 | 6,90 | |
Annual energy consumption cooling (3) | kWh/a | 134 | 188 | 238 | 3,05 | |
Annual energy consumption cooling (3) | kWh/a | 134 | 188 | 238 | 3,05 | |
COP (Min) (1) | W/W | 3,41 | 3,38 | 2,91 | 2,86 | |
COP (Max) (1) | W/W | 6,52 | 6,52 | 7,50 | 7,60 | |
Annual energy consumption heating (3) | kWh/a | 850 | 912 | 1.264 | 1.500 | |
Indoor air flow (Hi) | m³/min | 8,5 | 9,5 | 12,0 | 14,0 | |
Indoor air flow (Med) | m³/min | 7,0 | 7,0 | 9,5 | 10,5 | |
Indoor air flow (Lo) | m³/min | 6,0 | 6,0 | 6,5 | 8,0 | |
Moisture removal volume | L/h | 0,7 | 1,5 | 2,3 | 2,8 | |
Indoor sound pressure (Med) (4) | dB(A) | 28 | 30 | 34 | 37 | |
Indoor sound pressure (Lo) (4) | dB(A) | 25 | 25 | 27 | 31 | |
Indoor sound power (Hi) | dB(A) | 46 | 49 | 54 | 58 | |
Indoor sound power (Med) | dB(A) | 43 | 45 | 49 | 52 | |
Indoor sound power (Lo) | dB(A) | 40 | 40 | 42 | 46 | |
nanoe X Generator | Mark 2 | Mark 2 | Mark 2 | Mark 2 | ||
Outdoor unit | U-25PZ3E5 | U-36PZ3E5 | U-50PZ3E5 | U-60PZ3E5A | ||
Outdoor power source | V | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | |
Current in cooling (1p 220V / 3p 380) | A | 2,65 | 4,20 | 6,65 | 8,20 | |
Current in cooling (1p 230V / 3p 400) | A | 2,55 | 4,05 | 6,35 | 7,85 | |
Current in cooling (1p 240V / 3p 415) | A | 2,45 | 3,85 | 6,10 | 7,55 | |
Current in heating (1p 220V / 3p 380) | A | 3,40 | 3,95 | 5,695 | 7,70 | |
Current in heating (1p 230V / 3p 400) | A | 3,25 | 3,75 | 5,70 | 7,35 | |
Current in heating (1p 240V / 3p 415) | A | 3,10 | 3,60 | 5,45 | 7,05 | |
Outdoor air flow (Cool) | m³/min | 33,6 | 32,6 | 32,7 | 42,6 | |
Outdoor air flow (Heat) | m³/min | 34,0 | 34,0 | 31,9 | 41,5 | |
Outdoor sound pressure (Cool -Hi) | dB(A) | 46 | 46 | 46 | 47 | |
Outdoor sound pressure (Heat -Hi) | dB(A) | 47 | 47 | 48 | 48 | |
Outdoor sound power (Cool -Hi) | dB(A) | 64 | 64 | 64 | 64 | |
Outdoor sound power (Heat -Hi) | dB(A) | 66 | 66 | 64 | 65 | |
Outdoor dimension (Height) | mm | 619 | 619 | 619 | 695 | |
Outdoor dimension (Width) | mm | 824 | 824 | 824 | 875 | |
Outdoor dimension (Depth) | mm | 299 | 299 | 299 | 320 | |
Pipe length range | m | 3 ~ 15 | 3 ~ 15 | 3 ~ 20 | 3 ~ 40 | |
Elevation difference (in/out) (5) | m | 15 / 15 | 15 / 15 | 15 / 15 | 15 / 30 | |
Kit | KIT-25PY3Z5 | KIT-36PY3Z5 | KIT-50PY3Z5 | KIT-60PY3Z5 | ||
Remote controller | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | ||
EER (Min) (1) | W/W | 3,55 | 3,57 | 3,03 | 2,77 | |
EER (Max) (1) | W/W | 5,88 | 5,88 | 6,25 | 6,90 | |
Annual energy consumption cooling (3) | kWh/a | 134 | 188 | 238 | 3,05 | |
COP (Min) (1) | W/W | 3,41 | 3,38 | 2,91 | 2,86 | |
COP (Max) (1) | W/W | 6,52 | 6,52 | 7,50 | 7,60 | |
Annual energy consumption heating (3) | kWh/a | 850 | 912 | 1.264 | 1.500 | |
Indoor air flow (Hi) | m³/min | 8,5 | 9,5 | 12,0 | 14,0 | |
Indoor air flow (Med) | m³/min | 7,0 | 7,0 | 9,5 | 10,5 | |
Indoor air flow (Lo) | m³/min | 6,0 | 6,0 | 6,5 | 8,0 | |
Moisture removal volume | L/h | 0,7 | 1,5 | 2,3 | 2,8 | |
Indoor sound pressure (Med) (4) | dB(A) | 28 | 30 | 34 | 37 | |
Indoor sound pressure (Lo) (4) | dB(A) | 25 | 25 | 27 | 31 | |
Indoor sound power (Hi) | dB(A) | 46 | 49 | 54 | 58 | |
Indoor sound power (Med) | dB(A) | 43 | 45 | 49 | 52 | |
Indoor sound power (Lo) | dB(A) | 40 | 40 | 42 | 46 | |
nanoe X Generator | Mark 2 | Mark 2 | Mark 2 | Mark 2 | ||
Outdoor unit | U-25PZ3E5 | U-36PZ3E5 | U-50PZ3E5 | U-60PZ3E5A | ||
Outdoor power source | V | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | |
Current in cooling (1p 220V / 3p 380) | A | 2,65 | 4,20 | 6,65 | 8,20 | |
Current in cooling (1p 230V / 3p 400) | A | 2,55 | 4,05 | 6,35 | 7,85 | |
Current in cooling (1p 240V / 3p 415) | A | 2,45 | 3,85 | 6,10 | 7,55 | |
Current in heating (1p 220V / 3p 380) | A | 3,40 | 3,95 | 5,695 | 7,70 | |
Current in heating (1p 230V / 3p 400) | A | 3,25 | 3,75 | 5,70 | 7,35 | |
Current in heating (1p 240V / 3p 415) | A | 3,10 | 3,60 | 5,45 | 7,05 | |
Outdoor air flow (Cool) | m³/min | 33,6 | 32,6 | 32,7 | 42,6 | |
Outdoor air flow (Heat) | m³/min | 34,0 | 34,0 | 31,9 | 41,5 | |
Outdoor sound pressure (Cool -Hi) | dB(A) | 46 | 46 | 46 | 47 | |
Outdoor sound pressure (Heat -Hi) | dB(A) | 47 | 47 | 48 | 48 | |
Outdoor sound power (Cool -Hi) | dB(A) | 64 | 64 | 64 | 64 | |
Outdoor sound power (Heat -Hi) | dB(A) | 66 | 66 | 64 | 65 | |
Outdoor dimension (Height) | mm | 619 | 619 | 619 | 695 | |
Outdoor dimension (Width) | mm | 824 | 824 | 824 | 875 | |
Outdoor dimension (Depth) | mm | 299 | 299 | 299 | 320 | |
Pipe length range | m | 3 ~ 15 | 3 ~ 15 | 3 ~ 20 | 3 ~ 40 | |
Elevation difference (in/out) (7) | m | 15 / 15 (8) | 15 / 15 (8) | 15 / 30 (8) |
1) O cálculo do EER e do COP é efectuado de acordo com a norma EN14511.
2) Para modelos inferiores a 12kW, o SEER e o SCOP são calculados com base nos valores da norma EU/626/2011. Para modelos acima de 12kW, os valores ηsc / ηsh são calculados com base na norma EN 14825.
3) Definição de fábrica.
4) A pressão sonora das unidades apresenta o valor medido na posição 1,5 m abaixo da unidade. A pressão sonora é medida de acordo com a especificação Eurovent 6/C/006-97.
5) Ligue o tubo de encaixe de líquido (Ø6,35-Ø9,52) à unidade interior do lado da tubagem de líquido.
6) Ligue o tubo de encaixe de gás (Ø12,70-Ø15,88) à unidade interior do lado da tubagem de gás.
7) Quando instalar a unidade exterior numa posição mais elevada do que a unidade interior.
8) Unidade exterior localizada mais abaixo / unidade exterior localizada mais acima.
* Fusível recomendado para a unidade interior 3A.
** Os valores acima são no caso de nanoe™ X OFF.
*** Disponível no outono de 2021.
**** Dados provisórios.