Série PACi NX Elite Split Inverter+ · R32

As unidades mural com um elegante branco mate é ideal para diversos tipos de aplicações, tais como estúdios, ginásios, áreas com tetos elevados e até salas de servidores.

O design compacto e a superfície plana da unidade garantem uma instalação discreta, mesmo num espaço pequeno.

A próxima geração de ar condicionado comercial

Especificações

Ver tudo
Série PACi NX Elite Split Inverter+ · R32 MONOFÁSICO TRIFÁSICO
3.6 kW 5.0 kW 6.0 kW 7.1 kW 10.0 kW 7.1 kW 10.0 kW
Kit KIT-36PK3ZH5 KIT-50PK3ZH5 KIT-60PK3ZH5 KIT-71PK3ZH45 KIT-100PK3ZH45 KIT-71PK3ZH48 KIT-100PK3ZH48
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
EER (Min) (1) W/W 5,45 5,45 5,45 2,69 3,09 2,69 3,09
EER (Max) (1) W/W 4,49 3,61 3,02 5,79 5,34 5,79 5,34
Annual energy consumption cooling (3) kWh/a 150 219 297 365 520 370 526
COP (Min) (1) W/W 5,45 5,45 5,45 3,16 3,43 3,16 3,43
COP (Max) (1) W/W 4,17 3,55 3,40 5,56 5,54 5,56 5,54
Annual energy consumption heating (3) kWh/a 1.029 1.341 1.342 1.549 2.871 1.549 2.871
Indoor air flow (Hi) m³/min 13,0 16,0 20,0 20,0 22,0 20,0 22,0
Indoor air flow (Med) m³/min 11,0 13,5 17,5 17,5 18,5 17,5 18,5
Indoor air flow (Lo) m³/min 9,0 11,0 14,5 14,5 15,5 14,5 15,0
Moisture removal volume L/h 0,9 1,8 2,0 3,0 4,8 3,0 4,8
Indoor sound pressure (Med) (4) dB(A) 31 36 44 44 45 44 45
Indoor sound pressure (Lo) (4) dB(A) 27 32 40 40 41 40 41
Indoor sound power (Hi) dB(A) 51 56 63 63 65 63 65
Indoor sound power (Med) dB(A) 47 52 60 60 61 60 61
Indoor sound power (Lo) dB(A) 43 48 56 56 57 56 57
nanoe X Generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Outdoor unit U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 U-71PZH4E5 U-100PZH4E5 U-71PZH4E8 U-100PZH4E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 3,60 5,60 7,40 10,3 14,60 3,45 4,95
Current in cooling (1p 230V / 3p 400) A 3,45 5,35 7,10 9,80 14,00 3,25 4,70
Current in cooling (1p 240V / 3p 415) A 3,30 5,10 6,80 9,40 13,4 3,15 4,50
Current in heating (1p 220V / 3p 380) A 4,05 6,40 7,75 10,10 12,00 3,40 4,10
Current in heating (1p 230V / 3p 400) A 3,90 6,10 7,40 9,65 11,60 3,20 3,90
Current in heating (1p 240V / 3p 415) A ,3,70 5,85 7,10 9,25 11,10 3,10 3,70
Outdoor air flow (Cool) m³/min 34,1 42,0 42,0 62,0 76,0 62,0 76,0
Outdoor air flow (Heat) m³/min 36,4 42,0 42,0 66,0 70,0 66,0 70,0
Outdoor sound pressure (Cool -Hi) dB(A) 43 46 47 48 52 48 52
Outdoor sound pressure (Heat -Hi) dB(A) 44 48 50 50 52 50 52
Outdoor sound power (Cool -Hi) dB(A) 62 64 65 65 69 65 69
Outdoor sound power (Heat -Hi) dB(A) 64 67 69 67 69 67 69
Outdoor dimension (Height) mm 695 695 695 996 996 996 996
Outdoor dimension (Width) mm 875 875 875 980 980 980 980
Outdoor dimension (Depth) mm 320 320 320 370 370 370 370
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5 ~ 100 5 ~ 60 5 ~ 100
Elevation difference (in/out) (7) m 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 15 / 30 15 / 30 15 / 30
1) O EER e o COP são calculados com base na norma EN14511.
2) Para modelos abaixo dos 12 kW, o SEER e SCOP são calculados com base nos valores da diretiva UE/626/2011. Para modelos acima dos 12 kW, os valores do ηsc / ηsh são calculados com base na norma EN14825.
3) Configurações de fábrica.
4) O nível de pressão acústica das unidades mostra o valor medido num ponto situado a 1 metro à frente do corpo principal e 1 metro abaixo da unidade. A pressão acústica é medida de acordo com a especificação Eurovent 6/C/006-97.
5) Ligue o tubo do bocal do líquido (Ø6,35-Ø9,52) à lateral da tubagem de líquido na unidade interior.
6) Ligue o tubo do bocal do gás (Ø12,70-Ø15,88) à lateral da tubagem de gás na unidade interior.
7) Unidade exterior localizada mais abaixo / unidade exterior localizada mais acima.
8) Comprimento da tubagem até 30 m.
* Recomenda-se um fusível de 3 A para o interior.
** Os valores acima aplicam-se ao nanoe™ X OFF.