Série PACi NX Elite Consola de Teto Inverter+ · R32

As unidades montadas no teto proporcionam uma distribuição grande e ampla de ar, o que é ideal para espaços grandes

Todas as unidades têm a mesma altura e profundidade para uma aparência uniforme em instalações mistas.

A próxima geração de ar condicionado comercial

Especificações

Ver tudo
Série PACi NX Elite Consola de Teto Inverter+ · R32 MONOFÁSICO TRIFÁSICO
3.6 kW 5.0 kW 6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW
Kit KIT-36PT3ZH5 KIT-50PT3ZH5 KIT-60PT3ZH5 KIT-71PT3ZH45 KIT-100PT3ZH45 KIT-125PT3ZH45 KIT-140PT3ZH45 KIT-71PT3ZH48 KIT-100PT3ZH48 KIT-125PT3ZH48 KIT-140PT3ZH48
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
EER (Min) (1) W/W 2,69 3,29 3,01 2,67 2,69 3,29 3,01 2,67
EER (Max) (1) W/W 5,79 5,34 5,33 5,32 5,79 5,34 5,33 5,32
SEER/ηsc (2) % 7,7 A++ 7,4 A++ 7,5 A++ 7,3 A++ 7,3 A++ 278,4% 263,3% 7,2 A++ 7,2 A++ 277,3% 262,4%
Annual energy consumption cooling (3) kWh/a 160 237 280 326 456 331 462
COP (Min) (1) W/W 3,16 3,54 3,20 3,10 3,16 3,54 3,20 3,10
COP (Max) (1) W/W 5,56 5,54 5,52 5,50 5,56 5,54 5,52 5,50
SCOP/ηsc (2) % 4,9 A++ 4,8 A++ 4,8 A++ 4,7 A++ 4,5 A+ 175,6% 169,3% 4,7 A++ 4,5 A+ 175,6% 169,3%
Annual energy consumption heating (3) kWh/a 886 1167 1342 1.400 2.426 1.400 2.427
Indoor air flow (Hi) m³/min 14,0 15,0 20,0 21,0 30,0 34,0 35,0 21,0 30,0 34,0 35,0
Indoor air flow (Med) m³/min 12,0 12,5 17,0 18,0 25,0 28,0 29,0 18,0 25,0 28,0 29,0
Indoor air flow (Lo) m³/min 10,5 10,5 14,5 15,5 23,0 24,0 25,0 15,5 23,0 24,0 25,0
Moisture removal volume L/h 0,8 2,0 2,1 2,7 3,6 5,4 6,4 2,7 3,6 5,4 6,4
Indoor sound pressure (Med) (4) dB(A) 32 33 34 35 37 40 41 35 37 40 41
Indoor sound pressure (Lo) (4) dB(A) 28 28 29 30 34 35 36 30 34 35 36
Indoor sound power (Hi) dB(A) 54 55 56 57 60 64 65 57 60 64 65
Indoor sound power (Med) dB(A) 50 51 52 53 55 58 59 53 55 58 59
Indoor sound power (Lo) dB(A) 46 46 47 48 52 53 54 48 52 53 54
nanoe X Generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Outdoor unit U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 U-71PZH4E5 U-100PZH4E5 U-125PZH4E5 U-140PZH4E5 U-71PZH4E8 U-100PZH4E8 U-125PZH4E8 U-140PZH4E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 3,55 5,85 7,35 8,80 11,60 17,10 20,40 2,95 3,60 5,45 6,15
Current in cooling (1p 230V / 3p 400) A 3,40 5,60 7,05 8,40 11,10 16,40 19,50 2,80 3,40 5,15 5,85
Current in cooling (1p 240V / 3p 415) A 3,25 5,40 6,75 8,05 10,60 15,70 18,70 2,70 3,25 5,00 5,65
Current in heating (1p 220V / 3p 380) A 3,90 6,60 7,85 10,20 13,70 18,10 23,20 3,15 3,75 5,10 6,20
Current in heating (1p 230V / 3p 400) A 3,75 6,30 7,50 9,75 13,20 17,30 22,20 3,00 3,55 4,80 5,90
Current in heating (1p 240V / 3p 415) A ,3,60 6,05 7,20 9,35 12,70 16,60 21,20 2,90 3,40 4,65 5,65
Outdoor air flow (Cool) m³/min 34,1 42,0 42,0 62,0 76,0 86,0 89,0 62,0 76,0 86,0 89,0
Outdoor air flow (Heat) m³/min 36,4 42,0 42,0 66,0 70,0 78,0 83,0 66,0 70,0 78,0 83,0
Outdoor sound pressure (Cool -Hi) dB(A) 43 46 47 48 52 55 56 48 52 55 56
Outdoor sound pressure (Heat -Hi) dB(A) 44 48 50 50 52 55 56 50 52 55 56
Outdoor sound power (Cool -Hi) dB(A) 62 64 65 65 69 73 74 65 69 73 74
Outdoor sound power (Heat -Hi) dB(A) 64 67 69 67 69 73 74 67 69 73 74
Outdoor dimension (Height) mm 695 695 695 996 996 996 996 996 996 996 996
Outdoor dimension (Width) mm 875 875 875 980 980 980 980 980 980 980 980
Outdoor dimension (Depth) mm 320 320 320 370 370 370 370 370 370 370 370
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5 ~ 100 5 ~ 100 5 ~ 100 5 ~ 60 5 ~ 100 5 ~ 100 5 ~ 100
Elevation difference (in/out) (7) m 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30

1) O EER e o COP são calculados com base na norma EN14511.
2) Para modelos abaixo dos 12 kW, o SEER e SCOP são calculados com base nos valores da diretiva UE/626/2011. Para modelos acima dos 12 kW, os valores do ηsc / ηsh são calculados com base na norma EN14825.
3) Configurações de fábrica.
4) O nível de pressão acústica das unidades mostra o valor medido num ponto situado a 1 metro à frente do corpo principal e 1 metro abaixo da unidade. A pressão acústica é medida de acordo com a especificação Eurovent 6/C/006-97.
5) Ligue o tubo do bocal do líquido (Ø6,35-Ø9,52) à lateral da tubagem de líquido na unidade interior.
6) Ligue o tubo do bocal do gás (Ø12,70-Ø15,88) à lateral da tubagem de gás na unidade interior.
7) Unidade exterior localizada mais abaixo / unidade exterior localizada mais acima.
8) Comprimento da tubagem até 30 m.

* Recomenda-se um fusível de 3 A para o interior.
** Os valores acima aplicam-se ao nanoe™ X OFF.